HomeMy WebLinkAbout026.01 - L 503 - Landscape Details6' MAXSEE PLANSEXTERIORFINISH PERARCHVERTICAL SLATS TO MATCH ARCH6" X 6" SQ. STEEL TUBING.WELD WATER TIGHT CAP TO VERTICALSTEEL POSTS.2"X4" PRIME STUD SPACED 16" O.C.WELD ANGLE IRON TO STEELPOST. FASTEN STUD W/ .75"SCREWSCONCRETE ROOFDECK ANDWATERPROOFING.SEE ARCH AND STRUCTURAL.1L5031/2" = 1'-0"Steel Framed Patio Screen1'-4"3"6" X 6" SQ. STEEL TUBING.WELD WATER TIGHT CAP TO VERTICALSTEEL POSTS.VERTICAL SLAT SIDING TO MATCH ARCH2X4 HORIZONTAL STUD FASTENED TO STEELANGLE VIA. (2) 1" WOOD SCREWS THROUGHPRE-DRILLED STEEL ANGLE. FASTENVERTICAL SIDING PANELS PER ARCH ATHORIZONTAL 2X4 STUDS.1.5" x 1.5" STEEL ANGLE. WELD STEEL ANGLE TOSTEEL TUBING.ROOFDECK AND WATERPROFING PERARCH/STRUCTURALSTEEL EMBED, VERIFY DETAIL W/ STRUCTURALVERTICAL SLATS TO MATCH ARCH2X4 HORIZONTAL STUD1.5" X 1.5" STEEL ANGLE8'
6"PEDESTAL PAVERS PER PLAN1'-23
8"STEEL EMBED. SEAL WELDVERTICAL 6" TUBING TO EACHEMBED. VERIFY DETAIL WITHSTRUCTURAL.STEEL EMBED. SEAL WELDVERTICAL 6" TUBING TO EACHEMBED. VERIFY DETAIL WITHSTRUCTURAL.NOTE: CONTRACTOR SHALL PROVIDE SHOP DRAWINGSPRIOR TO FABRICATION AND CONSTRUCTION.2L5031" = 1'-0"Handrail @ Concrete Steps2'-11"
2'-11"2" X 1" SQ. TUBE STEEL RAIL W/ .25"RAIDUS CORNERSNOTE:1.SEE GRADING SHEET FOR ALL WALL HEIGHTS AND ADJACENTFINISHED GRADES.2.SEE PLANS FOR DIMENSIONS3.RAILING SHALL BE STEEL TUBE, POWDERCOATED BLACK4.RAILING SHALL EXTEND 12" BEYOND TOP AND BOTTOM TREAD5.RAILING SHALL BE NO LESS THAN 34" AND NO MORE THAN 36"ABOVE TREAD AND FINISHED PAVEMENT GRADEEMBED STEEL POSTIN CONCRETEBOARD FORM WALL PER PLAN.SEE GRADING PLAN FORWALL HEIGHTS.1'2'-11"3L5031" = 1'-0"Metal Handrail Elevation, TypNOTE:1.SEE GRADING SHEET FOR ALL WALL HEIGHTS AND ADJACENTFINISHED GRADES.2.SEE PLANS FOR DIMENSIONS3.RAILING SHALL BE STEEL TUBE, POWDER COATED BLACK4.RAILING SHALL EXTEND 12" BEYOND TOP AND BOTTOM TREAD5.RAILING SHALL BE NO LESS THAN 34" AND NO MORE THAN 36"ABOVE TREAD AND FINISHED PAVEMENT GRADE2" X 1" TUBE STEEL RAIL W/ .25"RAIDUS CORNERS63°90°0"1'EMBED STEELPOST INCONCRETESTAIR DETAIL PER CIVILSIDEWALK/PATIOPER PLAN.SEE CIVIL FORDETAILSBOARD FORM WALL .SEE PLANS FOR WALL DIMENSIONSAND HEIGHTS.4L5031" = 1'-0"Ramp Handrail At WallNOTE:1.SEE GRADING SHEET FOR ALL WALL HEIGHTS AND ADJACENTFINISHED GRADES.2.SEE PLANS FOR DIMENSIONS3.RAILING SHALL BE STEEL TUBE & FLAT BAR, POWDER COATED BLACK4.RAILING SHALL BE NO LESS THAN 34" AND NO MORE THAN 36" ABOVETREAD AND FINISHED PAVEMENT GRADELEVEL LANDINGPER PLAN.SEE CIVIL FORDETAILS2" X 1" TUBE STEEL RAIL W/ .25"RAIDUS CORNERS1-1/4″ WIDE FLAT BAR TURNED ON ENDWELDED TO POST4' O.C.MAX2'-11"
3"4"234"4" SQ TUBE STEEL POSTEMBED POSTS IN CONCRETE4' Privacy Fence1/2" = 1'-0"L50354'6"
3"
3'-9"
6"4"MAX 4' O.C.1'3 12"1"1"x4" CEDAR BOARD4"x4" CEDAR POST1" WOOD SCREW12" SONOTUBEFOOTING2'6" 34 MINUSCOMPACTED AGGREGATELandscapeDetailsL 503design5la.com406.587.4873dateissuedrawn by:checked by:filename:z:\brick capital block 104\autocad\01_sheets\block104-south_standarddetails.dwg
Block 104 South Building
Bozeman, Montana
AVD TMS/AVD
09/26/23SD / Pre-App02/28/24Site Plan Review03/13/24100% DDNO
T
F
O
R
C
O
N
S
T
R
U
C
T
I
O
N05/28/24Coordination08/22/24SP RC 1