Loading...
HomeMy WebLinkAbout048.6 L401-IRRIGATION DETAILSISOLATION VALVE DETAIL NTS4L4011.FINISH GRADE2.VALVE BOX ASSPECIFIED3.GATE VALVE ASSPECIFIED. LINE SIZE.4.SCH 80 PVC UNION(1 OF 2)5.MAIN LINE PIPE6.6" OF WASHED 34"AGGREGATE BASE7.BRICK SUPPORTS (1OF 4)1NOTES:1.VALVE TO BE SUPPORTED BY GRAVEL, PROVIDE BLOCK SHIM ASREQUIRED23456723675148KEY SPECIFICATIONSMAX PROGRAMSSTATIONSMAX SIMULSTATIONSMASTER VALVESFLOW SENSORSWEATHER SENSORSLX-IVMLX-IVM PRO10608554402401610108FEATUREMODEL91.2-WIRE CONTROLLER: RAIN BIRD ESP-LXIVM/PROW/ LXMM METAL CABINET & LXMMPED METALPEDESTAL. INSTALL CONTROLLER, CABINET &PEDESTAL PER MANUFACTURER'SRECOMMENDATIONS.2.CONCRETE PAD: 6" MIN. THICKNESS, 6" LARGERON ALL SIDES THAN PEDESTAL FOOTPRINT3.FINISH GRADE4.POWER SUPPLY WIRE5.1" SCH 40 PVC CONDUIT, FITTINGS & SWEEP ELLFOR POWER SUPPLY6.2" SCH40 PVC CONDUIT, FITTINGS & SWEEP ELLFOR TWO-WIRE CABLE7.MAX 2-WIRE PATH TO FIELD DEVICES USE ADIFFERENT CABLE JACKET COLOR FOR EACHPATH.8.COMPACTED SUBGRADE9.1" SCH 40 PVC CONDUIT, FITTINGS & SWEEP ELLFOR GROUND1L401IN METAL PEDESTALESP-LXIVM/PRO TWO-WIRE CONTROLLER NTSNOTES:1.ESP-LXIVM CONTROLLER IS AVAILABLE IN TWOMODELS. THE LXIVM W/ 60 STATIONS & THELMIVM-PRO W/ 240 STATIONS. REFER TO THECHART FOR DIFFERENCES B/W THE MODELS.2.PROVIDE PROPER GROUNDING COMPONENTSTO ACHIEVE GROUND RESISTANCE OF 10OHMS OR LESS.123456713898611101267L401WITH IVM-SOLXCZ-100-PRB-COM NTS1.WATERPROOF SPLICE CONNECTION: RAINBIRD WC20 (2 REQ.)2.RAIN BIRD DRIP KIT: XCZ-100-PRB-COMW/ IVM-SOL3.VALVE BOX W/ COVER: RAIN BIRD VB-STD4.FINISH GRADE OR TOP OF MULCH5.BRICK (1 OF 4)6.PVC PIPE7.3" MIN. DEPTH OF 34" WASHED GRAVEL8.PVC SCH 80 NIPPLE 1"9.PVC SCH 80 ELBOW10.PVC SCH 80 NIPPLE (2" LENGTH, HIDDEN)& PVC SCH 80 ELBOW11.PVC SCH 80 TEE OR ELBOW12.PVC SCH 40 MALE ADAPTER13.2-WIRE CABLE B/W DEVICES (FIELDDECODER, SENSOR DECODER, LINESURGE PROTECTOR CONTROLLER)NOTE:1.COIL AN ADDITIONAL 3' OF 2-WIRE CABLEIN VALVE BOX FOR EASY SERVICING.8L401WITH MPR NOZZLE1800 SERIES POP-UP SPRINKLER NTS1.FINISH GRADE/TOP OF MULCH2.POP-UP SPRAY SPRINKLER. RAIN BIRD1806/12-SAM W/ RAIN BIRD MPR NOZZLES3.1/2 INCH MALE NPT X .490 INCHBARB ELBOW: RAIN BIRD MODEL SBE-0504.PPE LATERAL PIPE5.SWING PIPE, 12 INCH LENGTH:RAIN BIRD MODEL SP-1006.PVC SCH 40 TEE OR ELLOUTDOOR WALL1234VT = VALVE TESTVT MVCOM56789101112AUX24 VAC GND SEN WR2WIRELESS SENSORWIRING DETAILSEE WIRING DETAILNOTES:1. FOR BEST PERFORMANCE, THE CONTROLLER INTERFACESHOULD BE INSTALLED AT LEAST FIVE FEET ABOVE THEGROUND.2. IT IS RECOMMENDED THAT THE CONTROLLER INTERFACEBE INSTALLED AWAY FROM SOURCES OF ELECTRICALINTERFERENCE (SUCH AS TRANSFORMERS,GENERATORS, PUMPS, FANS, ELECTRICAL METERBOXES) AND METAL OBJECTS TO MAXIMIZECOMMUNICATION RANGE.1235674COM 24 VAC GND SEN COM2L401WR2 SERIES CONTROLLER INTERFACEWIRELESS RAIN SENSOR (OUTDOOR) NTS1.RAIN BIRD CONTROLLER:RAIN BIRD ESP-4MOUTDOOR WALL MOUNT2.1-INCH PVC SCH 40 CONDUITAND FITTINGS FOR VALVE WIRES3.RAIN BIRD WR2 WIRELESS SENSORCONTROLLER INTERFACE4.CABLE HARNESS FOR CONTOLLERINTERFACE (30" MAX.)5.GROUND WIRE TO GROUNDING GRID6.JUNCTION BOX7.1/2-INCH PVC SCH 40 CONDUITTO POWER SUPPLY1047897611543213L401QUICK COUPLER NTS1.FINISH GRADE/ TOP OFMULCH2.QUICK-COUPLING VALVE3.VALVE BOX WITH COVER4.PVC SCH 80 NIPPLE(LENGTH AS REQUIRED)5.3" MINIMUM DEPTH OF 34"WASHED GRAVEL6.BRICK (1 OF 2)7.PVC SCH 40 STREET ELL8.PVC SCH 40 TEE OR ELL9.PVC MAIN LINE PIPE10.PVC SCH 40 ELL11.2" X 2" REDWOOD STAKEWITH STAINLESS STEELGEAR CLAMPS OREQUIVALENT SUPPORTSYSTEMNOTES:1.INSTALLATIONN TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.2.FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLINGVALVE INLET SIZE.59649821310212111.RAIN BIRD SERIES MASTER VALVE2.RAIN BIRD UFS SERIES FLOW SENSOR3.36" LENGTH OF COILED CONTROL WIRE4.3" MIN. DEPTH OF 34" WASHED GRAVEL5.BRICK (1 OF 4)6.JUMBO VALVE BOX WITH COVER7.FINISH GRADE8.SEE FLOW SENSOR WIRING DETAIL FOR WIRING9.CONCENTRIC REDUCER10.PVC MALE ADAPTER11.PVC CLOSE NIPPLE (1 OF 3)12.PVC UNION (1 OF 2)NOTES:1.THE UFS CAN BE INSTALLED IN A VERTICAL POSITION WITH THE FLOW ARROW POINTING UPWARDS.2.THE UFS SIZE MUST BE EQUAL TO OR SMALLER THAN THE INCOMING PIPE SIZE.3.THE UFS DOES NOT REQUIRE STRAIGHT PIPE BEFORE OR AFTER SENSOR PLACEMENT.4.NO BRICKS REQUIRED FOR RAIN BIRD VB-SERIES VALVE BOXES ONLY.5L401& ULTRASONIC FLOW SENSORMASTER VALVE NTS9L401THRUST BLOCK NTSNOTES:1.SIZE THRUST BLOCKS SHALL BE SPECIFIED ASSHOW IN THE TABLE.2.CONTROL WIRES SHALL NOT BE ENCASED INCONCRETE.3.ALL FITTINGS SHALL BE WRAPPED WITHPOLYETHYLENE TO PREVENT CONCRETE FROMADHERING TO PIPE, FITTINGS OR BOLTS.4.JOINTS AND BOLTS SHALL BE ACCESSIBLE FORREPAIRS.5.THRUST BLOCKS SHALL BE A MINIMUM OF 6"THICK.6.ONE 80 LBS. SACK OF CONCRETE SHALL COVER.6 FT.³PIPE SIZETEE AND PLUG90° BEND45° BEND1-1/2"2"2-1/2"3"4"6"8"10"14.93 FEET ²9.08 FEET ²5.25 FEET ²2.43 FEET ²1.48 FEET ²1.0 FEET ²0.69 FEET ²0.45 FEET ²0.63 FEET ²0.97 FEET ²1.41 FEET ²2.10 FEET ²3.45 FEET ²7.41 FEET ²12.83 FEET ²21.07 FEET ²11.44 FEET ²6.96 FEET ²4.02 FEET ²1.87 FEET ²1.14 FEET ²0.77 FEET ²0.53 FEET ²0.34 FEET ²1.BEARING SURFACE2.EXISTING OR MODIFIEDSOIL (SEE SPECIFICATIONFOR SOIL MODIFICATION)3.FLOW DIRECTION211312NOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE AND LATERAL LINE PIPE SIZE AND TYPE.2.DIRECT BURIAL CONTROL WIRES SHALL BE INSTALLED IN SCH. 40 PVC ELECTRICAL CONDUIT IFREQUIRED.3.2-WIRE IRRIGATION WIRE SHALL BE INSTALLED IN SCH. 40 PVC ELECTRICAL CONDUIT.4.DETECTABLE LOCATOR TAPE SHALL BE LOCATED SIX INCHES (6") ABOVE THE ENTIRE MAINLINE RUN.345610L401IRRIGATION TRENCHING NTS1.FINISHED GRADE2.PAVEMENT3.NON-PRESSURIZEDLINE (LATERAL LINE)4.DETECTABLELOCATOR TAPE5.PRESSURIZED LINE(MAINLINE)6.DIRECT BURIAL LOWVOLTAGE CONTROLWIRES24" MIN.6" 1'-0" IN PLANTING AREA 1'-6" IN PLANTING AREA3'-0" UNDERNEATH PAVEMENT NOTES:1.ALL ASSEMBLY PARTS (THREADED NIPPLES, FITTINGS, ETC.) SHALL BEGALVANIZED OR BRASS PER LOCAL CODES AND REQUIREMENTS.2.GALVANIZED NIPPLE SHALL EXTEND 12" PAST THE EDGE OF THE CONCRETEFOOTING.3.SCH. 80 PVC MALE ADAPTER SHALL BE USED IN CONNECTION FROMGALVANIZE TO THE MAINLINE.4.BACKFLOW PREVENTION DEVICE SHALL BE LOCATED AS CLOSE ASPOSSIBLE TO THE LANDSCAPE METER.5.BACKFLOW PREVENTION DEVICE SHALL BE LOCATED IN PLANTING AREAUNLESS APPROVED BYOWNER'S REPRESENTATIVE.6.SEE DETAIL FOR BACKFLOW CAGE INSTALLATION.7.ALL BACKFLOW PREVENTION DEVICES SHALL HAVE FREEZE BLANKETINCLUDED UPON INSTALLATION.8.ALL GALVANIZED CONNECTIONS SHALL TO BE MADE USING PIPE THREADSEALANT. ALL SCH. 80 PVC TO GALVANIZED CONNECTIONS TO BE MADEUSING TEFLON TAPE.FLOWDIRECTION12345678910111.BACKFLOW PREVENTIONDEVICE (SEE IRRIGATIONPLANS FOR MAKE ANDMODEL). INSTALL DEVICEPER THE LOCAL WATERPURVEYOR'S STANDARDSAND SPECIFICATION2.GALVANIZED NIPPLE3.4" THICK CONCRETE PAD,1" ABOVE FINISHEDGRADE. SEE BACKFLOWCAGE DETAIL4.CONCRETE THRUSTBLOCKS REQUIRED ONBACKFLOW DEVICES2-1/2" AND LARGER5.BRASS BALL VALVE6.THREADED GALVANIZEDNIPPLE7.GALVANIZED 90O ELBOW8.GALVANIZED UNION9.WRAP 20 MIL TAPE TWICEAROUND GALVANIZED PIPEUNDER FINISHED GRADEAND THROUGH THECONCRETE10.GALVANIZED COUPLING11.SCH 80 PVC MALEADAPTER11L401BACKFLOW PREVENTION DEVICE NTSAROUND GALVANIZED PIPENOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE SIZE AND TYPE.2.ALL SLEEVES SHALL BE SCH. 40 PVC PIPE.3.ALL SLEEVES SHALL EXTEND 12" BEYOND THE EDGE OF PAVEMENT.4.END OF SLEEVES SHALL BE LOCATED WITH A WOODEN STAKE ORPVC PIPE. LOCATORS SHALL RUN CONTINUOUSLY FROM THE END OFTHE SLEEVE TO FINISHED GRADE.1234561.PAVEMENT2.BASE ROCK3.CLEAN BACKFILL, 95% RELATIVECOMPACTION UNDER PAVING OR PERCIVIL ENGINEERS PLANS4.CONTROL WIRES, SLEEVE UNDERPAVING. INSTALL ADJACENT TOPRESSURIZED MAINLINE. BUNDLE SHALLBE NO MORE THAN 50% OF PIPEDIAMETER5.MAINLINE, SLEEVE UNDER PAVING TOBE TWO TIMES THE DIAMETER OF THEPRESSURIZED MAINLINE PIPE6.NON-PRESSURIZED LINE, SLEEVE UNDERPAVING TO BE TWO TIMES THEDIAMETER OF THE LATERAL LINE12L401PIPE BENEATH PAVEMENT NTS3'-0"6L401PEB OR PESB SERIES WITH IVM-SOLELECTRIC REMOTE-CONTROL VALVE NTS1.TWO-WIRE CABLE2.WATERPROOF SPLICE CONNECTIONRAIN BIRD WC2O (TWO REQUIRED)3.ID TAG4.REMOTE CONTROL VALVE: RAINBIRD PEB/PEBS/PEBS-R WITHIVM-SOL5.VALVE BOX WITH COVER: RAINBIRD VB-STD6.FINISH GRADE/TOP OF MULCH7.PVC SCH 80 CLOSE NIPPLE8.PVC SCH 80 ELL9.PVC SCH 80 NIPPLE (LENGTH ASREQUIRED)10.BRICK (1 OF 4)11.PVC MAINLINE PIPE12.SCH 80 NIPPLE (2-INCH LENGHT,HIDDEN) AND SCH 80 ELL13.PVC SCH 80 TEE OR ELL14.PVC SCH 40 MALE ADAPTER15.PVC LATERAL PIPE16.3-INCH MINIMUM DEPTH OF3/4-INCH WASHED GRAVELNOTE:1.COIL AN ADDITIONAL 3-FEET ORTWO-WIRE CABLE IN VALVE BOX FOREASY SERVICING.File Path Fowler Lane Bozeman, MT3084 Thorpe RoadBelgrade, Montana 59714406.924.8038aly@outdoordesignstudios.comRANGE 5 Any unauthorized reproduction or use of this information without the expressed written consent of Bechtle Architects is a violation of U.S. copyright laws. Copyright © 2023 Bechtle Architects -JOB:4515 Valley Commons Drive #201 Bozeman, MT 59718 406.585.4161 ph 406.585.6919 fax BECHTLE ARCHITECTSCONSTRUCTIONDOCUMENTSSEPT 3, 2024REVISION SCHEDULENo.DescriptionDateTHIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALEL401IRRIGATIONDETAILS 1SP O101/25/242SP O205/07/243SP O309/03/24