Loading...
HomeMy WebLinkAbout028 C7.3-DETAILSRANGE 5 APARTMENTS Bozeman, Montana Any unauthorized reproduction or use of this information without the expressed written consent of Bechtle Architects is a violation of U.S. copyright laws. Copyright © 2023 Bechtle Architects 3825 Valley Commons Drive #3 Bozeman, MT 59718 406.585.4161 ph 406.585.6919 fax BECHTLEARCHITECTS THIS LINE IS 1 INCH LONG WHEN PRINTED TO FULL SCALE May 07, 2024PO BOX 888 Belgrade, MT 59714SITE PLANSUBMITTALTAOMNNAR N GEOSEFSINAL ROPEINECOTEETHAN LNo. 60593PEELICNES D05/07/202423-013.1JOB:REVISION SCHEDULENo. Description Date1 SP 01 01/25/242 SP 02 05/07/24C7.3DETAILSNOTES• MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECH NOTE #6.32 FOR MANIFOLD SIZING GUIDANCE.• DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLDCOMPONENTS IN THE FIELD.• THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET.• THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE-SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS RESPONSIBLE FORDETERMININGTHE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE INCREASED OR DECREASED ONCE THIS INFORMATION ISPROVIDED.•NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE.ISOLATOR ROW PLUS(SEE DETAIL)PLACE MINIMUM 12.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDINGSTONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALLCHAMBER INLET ROWSBED LIMITSSTORMTECH SYSTEM #41SCALE: NTSCONCEPTUAL ELEVATIONS:MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.17MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):2.67MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):2.67MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):2.67TOP OF STONE:2.00TOP OF SC-160LP CHAMBER:1.508" ISOLATOR ROW PLUS INVERT:0.58BOTTOM OF SC-160LP CHAMBER:0.50BOTTOM OF STONE:0.00PROPOSED LAYOUT49STORMTECH SC-160LP CHAMBERS14 STORMTECH SC-160LP END CAPS6STONE ABOVE (in)6STONE BELOW (in)40STONE VOID941INSTALLED SYSTEM VOLUME (CF)(PERIMETER STONE INCLUDED)(COVER STONE INCLUDED)(BASE STONE INCLUDED)924SYSTEM AREA (SF)144.6SYSTEM PERIMETER (ft)*INVERT ABOVE BASE OF CHAMBERMAX FLOWINVERT*DESCRIPTIONITEM ONLAYOUTPART TYPEAMANIFOLD(DESIGN BY ENGINEER / PROVIDED BY OTHERS)BCONCRETE STRUCTUREW/WEIR6" SEE DETAILCINSPECTION PORTNOTES• MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECH NOTE #6.32 FOR MANIFOLD SIZING GUIDANCE.• DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLDCOMPONENTS IN THE FIELD.• THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET.• THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE-SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS RESPONSIBLE FORDETERMININGTHE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE INCREASED OR DECREASED ONCE THIS INFORMATION ISPROVIDED.•NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE.ISOLATOR ROW PLUS(SEE DETAIL)PLACE MINIMUM 12.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDINGSTONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALLCHAMBER INLET ROWSBED LIMITSSTORMTECH SYSTEM #52SCALE: NTS50.27'55.74'16.58'14.58'48.63'43.17'12.50'14.50'CONCEPTUAL ELEVATIONS:MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.17MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):2.67MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):2.67MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):2.67TOP OF STONE:2.00TOP OF SC-160LP CHAMBER:1.508" ISOLATOR ROW PLUS INVERT:0.58BOTTOM OF SC-160LP CHAMBER:0.50BOTTOM OF STONE:0.00PROPOSED LAYOUT36STORMTECH SC-160LP CHAMBERS12STORMTECH SC-160LP END CAPS6STONE ABOVE (in)6STONE BELOW (in)40STONE VOID712INSTALLED SYSTEM VOLUME (CF)(PERIMETER STONE INCLUDED)(COVER STONE INCLUDED)(BASE STONE INCLUDED)705SYSTEM AREA (SF)126.2SYSTEM PERIMETER (ft)*INVERT ABOVE BASE OF CHAMBERMAX FLOWINVERT*DESCRIPTIONITEM ONLAYOUTPART TYPEAMANIFOLD(DESIGN BY ENGINEER / PROVIDED BY OTHERS)BCONCRETE STRUCTUREW/WEIRNOTES• MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECH NOTE #6.32 FOR MANIFOLD SIZING GUIDANCE.• DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLDCOMPONENTS IN THE FIELD.• THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET.• THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE-SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS RESPONSIBLE FORDETERMININGTHE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE INCREASED OR DECREASED ONCE THIS INFORMATION ISPROVIDED.•NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE.ISOLATOR ROW PLUS(SEE DETAIL)PLACE MINIMUM 12.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDINGSTONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALLCHAMBER INLET ROWSBED LIMITSSTORMTECH SYSTEM #63SCALE: NTS48.63'43.17'12.42'10.42'CONCEPTUAL ELEVATIONS:MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.17MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):2.67MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):2.67MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):2.67TOP OF STONE:2.00TOP OF SC-160LP CHAMBER:1.508" ISOLATOR ROW PLUS INVERT:0.58BOTTOM OF SC-160LP CHAMBER:0.50BOTTOM OF STONE:0.00PROPOSED LAYOUT30STORMTECH SC-160LP CHAMBERS10 STORMTECH SC-160LP END CAPS6STONE ABOVE (in)6STONE BELOW (in)40STONE VOID606INSTALLED SYSTEM VOLUME (CF)(PERIMETER STONE INCLUDED)(COVER STONE INCLUDED)(BASE STONE INCLUDED)604SYSTEM AREA (SF)122.1SYSTEM PERIMETER (ft)*INVERT ABOVE BASE OF CHAMBERMAX FLOWINVERT*DESCRIPTIONITEM ONLAYOUTPART TYPEAMANIFOLD(DESIGN BY ENGINEER / PROVIDED BY OTHERS)BCONCRETE STRUCTUREW/WEIRNOTES• MANIFOLD SIZE TO BE DETERMINED BY SITE DESIGN ENGINEER. SEE TECH NOTE #6.32 FOR MANIFOLD SIZING GUIDANCE.• DUE TO THE ADAPTATION OF THIS CHAMBER SYSTEM TO SPECIFIC SITE AND DESIGN CONSTRAINTS, IT MAY BE NECESSARY TO CUT AND COUPLE ADDITIONAL PIPE TO STANDARD MANIFOLDCOMPONENTS IN THE FIELD.• THE SITE DESIGN ENGINEER MUST REVIEW ELEVATIONS AND IF NECESSARY ADJUST GRADING TO ENSURE THE CHAMBER COVER REQUIREMENTS ARE MET.• THIS CHAMBER SYSTEM WAS DESIGNED WITHOUT SITE-SPECIFIC INFORMATION ON SOIL CONDITIONS OR BEARING CAPACITY. THE SITE DESIGN ENGINEER IS RESPONSIBLE FORDETERMININGTHE SUITABILITY OF THE SOIL AND PROVIDING THE BEARING CAPACITY OF THE INSITU SOILS. THE BASE STONE DEPTH MAY BE INCREASED OR DECREASED ONCE THIS INFORMATION ISPROVIDED.•NOT FOR CONSTRUCTION: THIS LAYOUT IS FOR DIMENSIONAL PURPOSES ONLY TO PROVE CONCEPT & THE REQUIRED STORAGE VOLUME CAN BE ACHIEVED ON SITE.ISOLATOR ROW PLUS(SEE DETAIL)PLACE MINIMUM 12.50' OF ADSPLUS125 WOVEN GEOTEXTILE OVER BEDDINGSTONE AND UNDERNEATH CHAMBER FEET FOR SCOUR PROTECTION AT ALLCHAMBER INLET ROWSBED LIMITSSTORMTECH SYSTEM #124SCALE: NTSCONCEPTUAL ELEVATIONS:MAXIMUM ALLOWABLE GRADE (TOP OF PAVEMENT/UNPAVED):11.50MINIMUM ALLOWABLE GRADE (UNPAVED WITH TRAFFIC):3.17MINIMUM ALLOWABLE GRADE (UNPAVED NO TRAFFIC):2.67MINIMUM ALLOWABLE GRADE (TOP OF RIGID CONCRETE PAVEMENT):2.67MINIMUM ALLOWABLE GRADE (BASE OF FLEXIBLE PAVEMENT):2.67TOP OF STONE:2.00TOP OF SC-160LP CHAMBER:1.508" x 8" BOTTOM MANIFOLD INVERT:0.588" ISOLATOR ROW PLUS INVERT:0.58BOTTOM OF SC-160LP CHAMBER:0.50BOTTOM OF STONE:0.00PROPOSED LAYOUT93STORMTECH SC-160LP CHAMBERS16 STORMTECH SC-160LP END CAPS6STONE ABOVE (in)6STONE BELOW (in)40STONE VOID1703INSTALLED SYSTEM VOLUME (CF)(PERIMETER STONE INCLUDED)(COVER STONE INCLUDED)(BASE STONE INCLUDED)1651SYSTEM AREA (SF)220.2SYSTEM PERIMETER (ft)MAX FLOWINVERT*DESCRIPTIONITEM ONLAYOUTPART TYPE0.96"8" x 8" BOTTOM MANIFOLD, MOLDED FITTINGSAMANIFOLD2.2 CFS IN(DESIGN BY ENGINEER / PROVIDED BY OTHERS)BCONCRETE STRUCTUREW/WEIR6" SEE DETAIL (TYP 2 PLACES)CINSPECTION PORT*INVERT ABOVE BASE OF CHAMBER18.67'16.67'91.42'85.87'CBABABABAC8" x 8" BOTTOM MANIFOLD INVERT:0.580.96"8" x 8" BOTTOM MANIFOLD, MOLDED FITTINGS2.2 CFS IN8" x 8" BOTTOM MANIFOLD INVERT:0.580.96"8" x 8" BOTTOM MANIFOLD, MOLDED FITTINGS2.2 CFS IN8" x 8" BOTTOM MANIFOLD INVERT:0.580.96"8" x 8" BOTTOM MANIFOLD, MOLDED FITTINGS2.2 CFS IN