HomeMy WebLinkAbout027 - L7.0 - Irrigation DetailsNo.
REVISIONSFile Name: IMEG Project No: Date: Drawn By: Checked By: Sheet of DESCRIPTION DATECOPYRIGHTALL RIGHTS RESERVEDC23006847 L5.0 Irrigation.dwg2024Field Book No:1143 STONERIDGE DR
SUITE 2
BOZEMAN, MT 59718
PH: 406.582.9901
www.imegcorp.com
COMPASS APARTMENTS
BOZEMAN, MT
IRRIGATION DETAILS23006847ESEW08/27/2024L7.077TYPICAL SUPPLY HEADER.TYPICAL TECHLINE DRIPPERLINE TUBING.TYPICAL PVC OR POLYSUPPLY OR EXHAUST HEADER.LAYOUTISLANDAREAS: TRIANGULARIRREGULAR ODD CURVESIRREGULAR SLOPE FEED LAYOUTMANUAL LINE FLUSHING VALVE.TECHLINE CV LATERAL TUBING.LATERALS PARALLEL TO THECONTOURS OF THE SLOPE.PVC EXHAUST HEADER.TOE OFSLOPE.TOP OF SLOPE.PVC SUPPLYHEADER.REMOTE CONTROLVALVE ASSEMBLY.BRANCHING OUT LATERALSJOINING LATERALSTECHLINE CV MAXIMUM LENGTH OF SINGLE LATERAL (FEET)TECHLINE FLOW PER 100 FEETTECHLINE CV GENERAL GUIDELINES FOR WATERING TIME54" MAXIMUM ELEV. CHANGEWITHOUT CHECK VALVE. IFGREATER, INSTALL INLINE CHECKVALVES EVERY 54" IN ELEV.CHANGE.BOTTOM 1/3 OF SLOPE:CONVENTIONAL SPACING PLUS25%.TOP 2/3 OF SLOPE:CONVENTIONALSPACING.STEP 1: ADD LENGTH OF ALL TECHLINE LATERAL TUBING CONNECTED TO THE HEADER.STEP 2: DIVIDE THIS TOTAL LENGTH BY 100 TO INDICATE THE LENGHT IN UNITS OF 100.STEP 3: LOCATE THE GPM THAT APPLIES FOR EACH UNIT OF 100 FEET LENGTH ON THE CHART"TECHLINE FLOW PER 100 FEET". MULTIPLY THIS GPM NUMBER TIMES THE UNITS OF 100FEET FOR THE TOTAL GPM AT THIS HEADER.STEP 4: SIZE THE HEADER WITH THE FOLLOWING:1 TO 6 GPM: 3/4" HEADER.6 TO 10 GPM: 1" HEADER.10 TO 20 GPM:1 1/4" HEADER.20 TO 30 GPM: 1 1/2" HEADER.SUPPLY AND EXHAUST HEADER SIZING CHART (UNLESS NOTED ON PLANS)TYPICAL NETAFIM TECHLINE CV REQUIREMENTSN.T.S.TOTAL LENGTH OF TECHLINE TUBINGIN THIS AREA CAN NOT EXCEED THEMAX. LENGTH OF RUN.TYPICAL START CONNECTIONON EXHAUST HEADER.TYPICAL START CONNECTION ONSUPPLY HEADER.SEESUB-HEADERDETAIL.TYPICAL TECHLINE STARTCONNECTION.PARKING ISLAND TYPICAL LAYOUTMANUAL LINE FLUSHING VALVE PLUMBEDTO PVC OR POLY HEADER.SUPPLYHEADEREXHAUSTHEADERCHECK LONGESTLATERAL AGAINSTCHART FOR MAX.LENGTH OF SINGLELATERALTOTAL THE COMBINED LENGTHOF THESE LATERALS ANDCOMPARE TO THE CHART FORMAX. LENGTH OF SINGLELATERAL.FX-IR-NETA-DRIP-104IRRIGATION TRENCHING1 1/2" = 1'-0"12NOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE AND LATERALLINE PIPE SIZE AND TYPE.2.DIRECT BURIAL CONTROL WIRES SHALL BE INSTALLEDIN SCH. 40 PVC ELECTRICAL CONDUIT IF REQUIRED.3.2-WIRE IRRIGATION WIRE SHALL BE INSTALLED IN SCH.40 PVC ELECTRICAL CONDUIT.4.DETECTABLE LOCATOR TAPE SHALL BE LOCATED SIXINCHES (6") ABOVE THE ENTIRE MAINLINE RUN.24" MIN.6"1'-0" IN PLANTING AREAFINISHED GRADE1PAVEMENT2NON-PRESSURIZED LINE(LATERAL LINE)3DETECTABLE LOCATOR TAPE4PRESSURIZED LINE (MAINLINE)5DIRECT BURIAL LOW VOLTAGECONTROL WIRES634561'-6" IN PLANTING AREA3'0" UNDERNEATH PAVEMENT1FX-IR-FX-AUXEQ-08BRASS BALL ISOLATION VALVE1 1/2" = 1'-0"10"X15" RECTANGULAR BOX WITH6" EXTENSION.SET BOX FLUSHTO GRADE.ISOLATION BALL VALVEAS SPECIFIED, SAMESIZE AS MAIN LINE.SCHEDULE 80 THREADEDNIPPLE AS REQUIRED.PVC MAIN LINE.TWO 6X2X16 CONCRETE BLOCK CAPS,ONE ON EACH SIDE OF BOX.1/2" WIRE CLOTTH GOPHERSCREEN, WRAP UP SIDES.3FX-IR-FX-ISOV-02ICZ-151-40 DRIP CONTROL KIT WITH UNIONS1 1/2" = 1'-0"1SUPER JUMBO VALVE BOX12FINISH GRADE23DRIP ZONE KITMODEL ICZ-151-40 WITH FILTER (TIP45 DEGREES) REGULATOR 40 PSI34WATERPROOF CONNECTORS (2)4518-24" COILED WIRE56SCH 80 T.O.E. NIPPLE67MAIN LINE PIPE & FITTINGS78BRICK SUPPORTS (7)893/4" MINUS WASHED GRAVEL910LATERAL PIPE AND FITTINGS1011PVC SLIP UNIONS (2)1116361176115FX-IR-HUNT-DRIP-19NOTES:1- ALL THREADED CONNECTIONS SHALL BE INSTALLED USING TEFLON TAPE.2- VALVE BOX SHALL BE WRAPPED WITH A MINIMUM 3 MIL THICK PLASTIC AND SECURED TO THE VALVE BOX USING DUCT TAPEOR ELECTRICAL TAPE.3- ALL QUICK COUPLERS SHALL BE INSTALLED A MINIMUM OF 18" OFF OF THE MAINLINE.4- VALVE BOXES SHALL BE LOCATED IN PLANTING AREAS.QUICK COUPLER VALVE1 1/2" = 1'-0"ROUND VALVE BOX WITHLOCKING LID.FINISHED GRADE.PAVEMENT.MAINLINE.(SEE IRRIGATION PLANS FOR SIZING).SCH. 80 PVC TEE OR ELBOW.STAINLESS STEELSCREW CLAMP.#6 X 48" REBAR.SCH. 80 PVC SWING JOINT.SCH. 80 PVC NIPPLE.QUICK COUPLER VALVE. (SEE IRRIGATIONLEGEND FOR MAKE AND MODEL NUMBER).4-8"7FX-IR-FX-QUIC-01DRIPLINE FLUSH VALVE AT GRADE3" = 1'-0"COMPRESSION TEE AS OCCURS.DRIPLINE STAKING AS NOTED.DRIPLINE WITH EMITTERS AS NOTED.DRIPLINE STAKE AT COUPLER.DRIPLINE COMPRESSION COUPLER.FLUSH CAP AT GRADE.6FX-IR-FX-DRIP-07IRRIGATION CONTROLLER (PRO-HC)NOT TO SCALE2C.PHC.01PVC MAINLINE.CENTER FEED EXAMPLEEND FEED EXAMPLETYPICAL OFFSET2" FROMHARDSCAPE, 4"FROM PLANTEDAREA.TYPICAL OFFSET 2" FROMHARDSCAPE, 4" FROMPLANTED AREA.TYPICAL TECHLINE TUBINGLATERALS WITH EMITTERSPACING AS NOTED.STAPLE (TLS6) AT ALL TEES,ELLS, AND AT 5' O.C. ATCLAY, 4' O.C. AT LOAM, OR 3'O.C. AT SAND.POLYETHYLENE OR PVCSUPPLY HEADER, SIZE AS PERHEADER SIZING CHART.MANUAL LINE FLUSHINGVALVE PLUMBED TOEXHAUST HEADER, AS FARFROM THE SUPPLY HEADERAS POSSIBLE.FLUSHING VALVE ATEACH EXHAUST END.MAXIMUM LENGTH OF SINGLE
LATERAL, SEE CHART.TYPICAL VALVE, FILTER,PRESSURE REGULATOR.MAXIMUM LENGTH OF SINGLE
LATERAL, SEE CHART.LEGEND:1.IRRIGATION CONTROLLER (PRO-HC) PER PLAN.2.IRRIGATION CONTROL WIRE IN CONDUIT. SIZE AND TYPE PER LOCALCODES.3.ELECTRICAL SUPPLY CONDUIT. CONNECT TO POWER SOURCE, J-BOXINSIDE CONTROLLER.4.ADJACENT SURFACE TO MOUNT CONTROLLER PER PLANNOTE:1.MOUNT CONTROLLER LCD SCREEN AT EYE LEVEL. CONTROLLER SHALLBE HARD-WIRED TO GROUNDED 110 VAC POWER SOURCE#0'-10.5" OPENDOOR WIDTH4.25"WIDTH21443FRONT ELEVATIONRIGHT ELEVATION1 COB COMMENTS