Loading...
HomeMy WebLinkAbout025 - L5.0 - Irrigation Notes and Schedule LU IRRIGATION NOTES: IRRIGATION SCHEDULE WATERING SCHEDULE (BETWEEN 1OAM AND 8PM) a N 001 1. CONTRACTOR TO VERIFY EXISTING CONDITIONS.ALL EXISTING UTILITIES ARE TO BE LOCATED SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI NUMBER MODEL TYPE PRECIP SUN MON TUE WED THU FRI SAT IN./WEEK MIN./WEEK GAL./WEEK GAL./DAY o BEFORE ANY TRENCHING OF ANY KIND BEGINS. 2. PROTECT ALL EXISTING IMPROVEMENTS TO REMAIN AND REPAIR BACK TO ORIGINAL CONDITION p eO OO O© HUNTER PROS-06-PRS40-CV SR SERIES 10 40 1 HUNTER ICZ-151-XL-40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 min 1 141 292 97.3 AT CONTRACTOR'S EXPENSE IF DAMAGE OCCURS RESULTANT FROM CONTRACTOR'S 20 2N au 4H 00 6N TURF SPRAY,40PSI REGULATED 61N.POP-UP,DRAIN 2 HUNTER ICZ- XL - 40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 min 1 141 609 203 OPERATIONS OR NEGLIGENCE. CHECK VALVE 3 HUNTER ICZ-151-XL40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 min 1 141 544 181 3. AREAS DISTURBED BY CONTRACTOR'S OPERATIONS AS PER SPECIFICATIONS. A DISTURBED 4 HUNTER MP3000 PROS-06-PRS40-CV-F HUNTER ICZ-151-XL40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 min 1 140 574 191 AREA SHALL BE WHERE CONSTRUCTION ACTIVITIES INCLUDING TRENCHING,DEMOLITION, 5 HUNTER ICZ-151-XL40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 min 1 141 299 99.6 EARTHWORK,MATERIAL STORAGE,STAGING,PARKING,OR ANY OTHER FORM OF EXCAVATION, ILI TURF ROTATOR,61N.POP-UP WITH FACTORY INSTALLED 1 40 6 HUNTER ICZ-151-XL40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 min 1 141 416 139 COMPACTION,OR TRAFFIC RESULTS IN THE REMOVAL OR DISPLACEMENT OF EXISTING GROUND `a 0 CHECK VALVE,FLOGUARD,PRESSURE REGULATED TO 40 7 HUNTER ICZ-151-XL-40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 in 1 141 759 253 B=BLUE ADJ MP ROTATOR NOZZLE ON PRS40 BODY. COVER OR GRADE. COORDINATE WITH GENERAL CONTRACTOR. PSI, 8 HUNTER PGV-101G TURF ROTARY 0.81 in/h 25 min 25 min 25 min 1 75 1,711 570 4. COORDINATE WORK THIS SHEET WITH ALL OTHER TRADES. ARC 90-210,Y=YELLOW ADJ ARC 210-270,A=GRAY 360 ARC. Z O 9 HUNTER ICZ-151-XL40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 min 1 141 635 212 5. INSTALL IRRIGATION SYSTEM AS DETAILED AND PER MANUFACTURER'S SPECIFICATIONS. HUNTER MP3500 PROS-06-PRS40-CV-F 10 HUNTER ICZ-151-XL40 AREA FOR DRIPLINE 0.43 in/h 47 min 47 min 47 in 1 141 567 189 O P_ 6. PROVIDE ALL COMPONENTS REQUIRED TO COMPLETELY WINTERIZE THE IRRIGATION SYSTEM - A 0.3 /h in n 1 3 d TURF ROTATOR,61N.POP-UP WITH FACTORY INSTALLED WHETHER OR NOT SPECIFIED HEREIN. CHECK VALVE,FLOGUARD,PRESSURE REGULATED TO 40 9 40 12 HUNTER PGV-101G TURF ROTARY 0.41 in/h 50 min 50 min 50 min 1 149 3,557 1,186 U) 7. INSTALL AN AIR RELIEF VALVE AT MAINLINE HIGH POINTS AND MANUAL DRAINS A LOW a PSI,MP ROTATOR NOZZLE ON PR940 BODY.LB=LIGHT 13 HUNTER PGV-101G BUBBLER 30.64 in/h 1 min 1 min 1 min 1 2 28 9.33 > U POINTS.INSTALL CONTROL WIRES FROM ELECTRIC VALVES TO CONTROLLER,AS NECESSARY. BROWN ADJUSTABLE ARC,90-210. 14 HUNTER PGV-101G BUBBLER 30.64 in/h 1 min 1 min 1 min 1 2 24 8 LLI W B. SLEEVES SHALL BE(2)SIZES LARGER THAN PIPE OR COMBINATION OF PIPES THEREIN 15 HUNTER PGV-101G BUBBLER 30.64 in/h 1 min 1 min 1 min 1 2 12 4 ENCLOSED,WITH MINIMUM SIZE TO BE 4". SUPPLY(1)EXTRA SLEEVE WITH EACH MAIN LINE HUNTER MP800SR PROS-06-PRS40-CV-F 16 HUNTER PGV-101G BUBBLER 30.64 in/h 1 min 1 min 1 min 1 2 24 8 SLEEVE FOR CONTROL WIRES. BORE UNDER EXISTING PAVING WHERE REQUIRED.BORE TURF ROTATOR,61N.POP-UP WITH CHECK VALVE, 17 HUNTER PGV-101G BUBBLER 30.64 in/h 1 min 1 min 1 min 1 2 28 9.33 SEPARATELY FOR CONTROL WIRES. e00A EOF FLOGUARD,PRESSURE REGULATED TO 40 PSI,MP 7 40 18 HUNTER PGV-101G BUBBLER 30.64 in/h 1 min 1 min 1 min 1 2 16 5.33 F_ 9. THE IRRIGATION PLANS ARE DIAGRAMMATIC AND IS INTENDED TO CONVEYTHE GENERAL ROTATOR NOZZLE ON PRS40 BODY.ADJ=ORANGE AND TOTALS: 551 551 551 1,645 10,630 3,543 Z LAYOUT OF IRRIGATION SYSTEM COMPONENTS.ALL IRRIGATION EQUIPMENT SHALL BE GRAY(ARC 90-210),360=LIME GREEN AND GRAY(ARC 360) LLI INSTALLED IN PLANTING AREAS WHEREVER POSSIBLE.LOCATE MAINLINE AND VALVES NEAR 2 WALKS WHERE FEASIBLE. HUNTER MP815 PROS-06-PRS40-CV-F TREE WATERING 20 GALLONS PER WEEK FROM SPRING UNTIL EARLY FALL. 2 10.CONTRACTOR SHALL VERIFY THE AVAILABLE WATER PRESSURE AT THE SITE PRIOR TO TURF ROTATOR,61N.POP-UP WITH CHECK VALVE, 0 CONSTRUCTION.REPORT ANY DISCREPANCIES BETWEEN THE WATER PRESSURE SHOWN ON [j FLOGUARD,PRESSURE REGULATED TO 40 PSI,MP 22 40 THE DRAWING AND THE ACTUAL PRESSURE READING. 815 ROTATOR NOZZLE ON PRS40 BODY.M=MAROON AND VALVE SCHEDULE CRITICAL ANALYSIS COp 11.CONTACT THE LOCAL UNDERGROUND UTILITY SERVICES FOR UTILITY LOCATION AND GRAY ADJ ARC 90 TO 210,L=LIGHT BLUE AND GRAY 210 TO U IDENTIFICATION. NUMBER MODEL SIZE TYPE GPM HEADS WIRE PSI PSI @ POC PRECIP Generated: 2024-09-2617:24 12.PERFORM EXCAVATION IN THE VICINITY OF UNDERGROUND UTILITIES WITH CARE AND IF HUNTER PROS-04-CV-MSBN MUNICIPAL WAMR SUPPLY Z M NECESSARY,BY HAND. THE CONTRACTOR BEARS FULL RESPONSIBILITY FOR THIS WORK AND 9 4P m 4 (ID MULTI-STREAM BUBBLER,41N.POP-UP,FACTORY 66 30 1 HUNTER ICZ-151-XL40 1-112" AREA FOR DRIPLINE 2.07 279.8 L.F. 384.1 42.0 54.0 0.43 in/h P.O.C.NUMBER:01 DISRUPTION OR DAMAGE TO UTILITIES SHALL BE REPAIRED IMMEDIATELY AT NO EXPENSE TO 250 500 50H 10H soF zoF INSTALLED DRAIN CHECK VALVE,25=.25GPM,50=0.5GPM, 2 HUNTER ICZ-151-XL-40 1-112" AREA FOR DRIPLINE 4.32 617.9 L.F. 389.0 42.6 54.7 0.43 in/h Water Source Information: THE OWNER. 10=1.OGPM,20=2.OGPM. 3 HUNTER ICZ-151-XL40 1-112" AREA FOR DRIPLINE 3.86 547.1 L.F. 394.1 43.0 55.0 0.43 in/h 13.WHERE PROVIDED,AREA TAKEOFFS AND IRRIGATION QUANTITY ESTIMATES IN SCHEDULES ARE 4 HUNTER ICZ-151-XL40 1-112" AREA FOR DRIPLINE 4.1 583.3 L.F. 399.6 43.7 55.7 0.43 in/h FLOW AVAILABLE FOR INFORMATION ONLY. CONTRACTOR IS RESPONSIBLE FOR COMPLETING THEIR OWN 5 HUNTER ICZ-151-XL40 1-112" AREA FOR DRIPLINE 2.12 287.2 L.F. 460.4 42.0 54.0 0.43 in/h Water Meter Size: 1-1/2" QUANTITY TAKEOFFS FOR ALL MATERIALS AND SIZES SHOWN ON DRAWINGS. DISCREPANCIES 6 HUNTER ICZ-151-XL40 1-112" AREA FOR DRIPLINE 2.95 412.1 L.F. 527.3 42.3 54.3 0.43 in/h Flow Available 45.35 GPM SHOULD BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT FOR CLARIFICATION. HUNTER ICZ-151-XL40 1-1/2" 7 HUNTER ICZ-151-XL40 1-112" AREA FOR DRIPLINE 5.38 776.3 L.F. 536.4 42.0 54.2 0.43 in/h ° 14.CONTRACTOR IS RESPONSIBLE TO'RESTORE ALL AREAS OF THE SITE,OR ADJACENT AREAS, DRIP CONTROL ZONE KIT. 1-1/21N.ICV GLOBE VALVE WITH 8 HUNTER PGV-101G 1" TURF ROTARY 22.82 29 646.4 46.6 61.6 0.81 in/h PRESSURE AVAILABLE a WHERE DISTURBED TO A CONDITION THAT MEETS OR EXCEEDS THE CONDITIONS PRIOR TO THE 11N.HY100 FILTER SYSTEM.PRESSURE REGULATION: 10 9 HUNTER ICZ-151-XL40 1-1/2" AREA FOR DRIPLINE 4.5 644.0 L.F. 651.5 42.6 54.7 0.43 in/h Static Pressure at POC: 75 PSI "'m DISTURBANCE. 40PSI.FLOW RANGE:20 GPM TO 60 GPM. 120 MESH 10 HUNTER ICZ-151-XL40 1-1/2" AREA FOR DRIPLINE 4.02 542.3 L.F. 424.4 42.3 54.3 0.43 in/h Elevation Change: 5.00 ft a E 15.ALL LINES SHALL SLOPE TO DRAIN ADD MANUAL DRAINS AT ALL MAINLINE LOW POINTS AS STAINLESS STEEL SCREEN.1-1/21N.INLET X SINGLE 21N. - - L 0. In Service Line Size: 1 1/2" a NECESSARY FOR COMPLETE DRAINAGE OF THE ENTIRE SYSTEM.INDICATE ALL DRAIN OUTLET 12 REM=-gal HUNTER PGV-101G 1" TURF ROTARY 23.87 10 542.5 49.5 65.0 0.41 in/h Length of Service Line: 20 ft LOCATIONS ON'AS-BUILT'DRAWINGS. 13 oaa HUNTER PGV-101G 1" BUBBLER �T 14 14 521.0 32.5 45.8 30.64 in/h Pressure Available: 72 PSI PIPE TRANSITION POINT IN DRIP BOX 16.ALL MAINLINES,LATERAL LINES,AND CONTROL WIRES UNDER PAVING SHALL BE INSTALLED IN 36 14 oaa HUNTER PGV-101G 1" BUBBLER ;s '" 12 12 656.4 34.3 47.4 30.64 inch PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP SEPARATE SLEEVES. 15 oaa HUNTER PGV-101G 1" BUBBLER ,tea*oF>.w 6 6 589.8 32.2 44.5 30.64 inRl DESIGN ANALYSIS 17.ALIGN VALVE BOXES PARALLEL WITH EDGE OF PAVEMENT/PLANTING BEDS,WHERE FEASIBLE, TUBING WITH RISER IN 61N.DRIP BOX. 16 oaE HUNTER PGV-101G 1" BUBBLER 12 12 307.8 33.7 46.8 30.64 inch Maximum Station Flow: 23.87 GPM LOCATE THE EDGE OF VALVE BOX 12"-18"FROM EDGE OF PAVEMENT. NETAFIM TLSOV 17 aaa HUNTER PGV-101G 1" BUBBLER 14 14 83.2 37.4 49.6 30.64 inch Flow Available at POC: 45.35 GPM 18.THE CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER LINES AND VALVES FOR OPTIMUM NETAFIM TLSOV-1/21N.MANUAL FLUSH VALVE,BARBED 18 oaaq HUNTER PGV-101G 1" BUBBLER 8 8 604.6 32.6 45.3 30.64 inch Residual Flow Available: 21.47 GPM PERFORMANCE.INSTALL DRIPLINE WITH THE APPROPRIATE LOCATION AND RADIUS FOR THE T INSERT.INSTALL IN 101N.BOX,WITH ADEQUATE BLANK OR 11 Common Wire 1,281 AREA TO BE COVERED. IN.COBRAIN.TUBING TO EXTEND VALVE OUT OF VALVE Critical Station: 13 rc BOX.2/31N FITS TECHLINE HCVXR,HCVXR-RW/RWP,CV, Design Pressure: 40 PSI ° DL,RW AND RWP DRIPLINES,AND PE IRRIGATION HOSE Friction Loss: 4.68 PSI c AREA TO RECEIVE DRIPLINE Fittings Loss: 0.47 PSI NETAFIM TLCV-06-18 Elevation Loss: 0 PSI o TECHLINE PRESSURE COMPENSATING LANDSCAPE 5,250 L.F. Loss through Valve: 4 9.5 PSI � _N Pressure Reg.at Critical Station: PSI m DRIPLINE WITH CHECK VALVE.0.6 GPH EMITTERS AT 18" Loss for Fittings: 0.32 0.32 PSI �u, O.C.DRIPLINE LATERALS SPACED AT 18"APART,WITH Loss for Main Line: 3.21 PSI EMITTERS OFFSET FOR TRIANGULAR PATTERN.17MM. Loss for POC to Valve Elevation: 0 PSI SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY Lss for BaerM: 10.7 PSI Looss for Water Meter: 1.19 PSI i ER PGV-101G V Critical Station Pressure at POC: 65.0 PSI LASTIC ELECTRIC REMOTE CONTROL VALVE,FOR Pressure Available: 72 PSI ENTIAULIGHT COMMERCIAL USE.FEMALE NPT 8Residual Pressure Available: 7.02 PSI /OUTLET.GLOBE CONFIGURATION,WITH FLOW ROL. I7 QUICK COUPLER VALVE,YELLOW RUBBER COVER,RED 2 w BRASS AND STAINLESS STEEL,WITH 11N.NPT INLET, J 2-PIECE BODY. W SHUT OFF VALVE 6 W BF FEBCO 825Y V 1 U REDUCED PRESSURE BACKFLOW PREVENTER U HUNTER WR-CLIK tLI U) . WOIK RAIN SENSOR,INSTALL WITHIN 1000 FT OF CONTROLLER, 1 c Q IN LINE OF SIGHT.22-28 VACNDC 100 MA POWER FROM G TIMER TRANSFORMER.MOUNT AS NOTED. z O HUNTER HFS-200 Q FS FLOW SENSOR FOR USE WITH ACC CONTROLLER,21N. 1 Q Z SCHEDULE 40 SENSOR BODY,24 VAC,2 AMP. a < w M❑ WATER METER 1-1/2" 1 Q LU LU IRRIGATION LATERAL LINE:PVC SCHEDULE 40 1" 4,328 L.F. C0 NU) 0 O IRRIGATION LATERAL LINE:PVC SCHEDULE 40 1 1/2" 168.2 L.F. Q m Z IRRIGATION MAINLINE:PVC SCHEDULE 40 c z IRRIGATION MAINLINE:PVC SCHEDULE 401 1/2" 1,212 L.F. O O IRRIGATION MAINLINE:PVC SCHEDULE 40 2" 68.9 L.F. U '�Qr� PIPE SLEEVE:PVC CLASS 200 SDR 21 803.7 L.F. V va callous o LL � # Valve Number 6 Valva Flow ID ale 5¢e IMEG Project No: o IRRIGATION WATER REQUIREMENT(IWR)IN UNITS OF GALLONS PER YEAR 23006847 COOL SEASON TURFGRASS 18.4 GALLONS/0 SF/YEAR=O GAL. File Name: o DROUGHT-ADAPTED WOODY PLANTS AND HERBACEOUS PERENNIALS 5.4 GALLONS/12,720 SF/YEAR=68,688 GAL. 23006847 L5.0 lnlgWlon.dwg o DROUGHT TOLERANT 1.8 GALLONS/0 SF/YEAR=O GAL. 2024 TOTAL 68,688 GAL./YEAR ©COPYRIGHT ALL RIGHTS RESERVED Field Book No: Drawn By: ES �g Checked By: EW Date: 09/27/2024 Eo L5.0 a% Sheet 5 of 7