Loading...
HomeMy WebLinkAboutRidge - Lot 7A Fire LineWS ///4 W4 W4 W 4 WFDC8 W 8 W 8 WT T T T T TEEEEE E EEEEEEEEEEEEEEEETTTTTGGGGGG//////////////////////////////////////////////// /// /// /// /// ///////////////////////////////////////////////////////////////////////////////////////////// ////////////////////////////////////////////////////////////SDSDSD SD0+000+501+001+3310.0'1.30'1.30'7.47'3.53'CONNECT TO EXISTING DIP STUBINSTALL 8x4 REDUCER & 4" GATE VALVESTA:0+00.00TOP:4806.14INSTALL 4" 45° HORIZ. BENDSTA:0+02.00TOP:4806.51INSTALL 4" 45° HORIZ. BENDSTA:1+13.75TOP:4808.86INSTALL 4" 90° VERTICAL BENDW/ MECHANICAL RESTRAINT & THRUST BLOCKSTA:1+31.00TOP:4809.22INSTALL 4" OS&Y VALVE IN FIRE ROOMSET BTM OF OS&Y 18" ABOVE F.F.E.STA:1+31.00FFE:4815.72131 LF 4" D.I.P. CLASS 51 FIRE LINEINSTALL 4" 45° HORIZ. BENDSTA:0+13.50TOP:4806.75INSTALL 4" 90° HORIZ. BENDSTA:0+58.50TOP:4807.70FDC///1.30'1.30'7.47'3.53'11"X17": 1"= 20 ftNGRAPHIC SCALE1 inch = ft.0( IN FEET )5101010H:\1086\018\ACAD\SHEETS\W-1-FIRE_AB.dwg Plot Date: 5/9/2023 3:27 PMHEADWATERSPROJECT NUMBERDRAWING NUMBERDRAWN BY:DATE:2023VERIFY SCALETHESE PRINTS MAY BEREDUCED. LINE BELOWMEASURES ONE INCH ONORIGINAL DRAWING. MODIFY SCALE ACCORDINGLY© HEADWATERS ENGINEERING, INC.REVISION DATE:190 NORTHSTAR LANE, BOZEMAN, MT 59718HEADWATERSMT.NET406-581-5730PROJECT LOCATIONMONTANABOZEMAN05/09/202305/09/2023AGCLASS 1 FIRE SERVICE LINE PLAN & PROFILE AB4351 FALLON ST.THE RIDGE LOT 7A1086.018W-1 AB RAVALLI ST.(60' R.O.W.)EXISTING CURBPROPOSED SIDEWALKCONSTRUCTION NOTES:1. ALL INFRASTRUCTURE SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE MONTANA PUBLIC WORKS & CITY OF BOZEMAN MODIFICATIONS.2. THE CONTRACTOR SHALL CONTACT ONE CALL @ 1-800-424-5555 FOR ON SITE UTILITY LOCATION. ALL UTILITIES SHALL BE MARKED BEFORE DIGGING. UTILITIES SHOWN ARE FOR PLANNINGPURPOSES ONLY.3. THE CONTRACTOR SHALL NOTIFY THE BOZEMAN WATER & SEWER DEPARTMENT A MINIMUM OF 24 HOURS PRIOR TO BEGINNING ANY WORK. ALL VALVES TO BE OPERATED BY CITY OF BOZEMANWATER AND SEWER DEPARTMENT.4. MINIMUM OF 2' SEPARATE BETWEEN SERVICES INSTALLED IN SAME TRENCH.5. FIRE SERVICE LINE SHALL BE DISINFECTED IN ACCORDANCE WITH MPW AND COB. FLUSHING AND PRESSURE TESTING OF THE LINE SHALL BE DONE IN ACCORDANCE WITH NFPA 6. TWO COPIESOF THE BAC-T TEST RESULTS ARE TO BE SUBMITTED TO THE CITY ENGINEERING DEPARTMENT.7. OS&Y VALVE SHALL BE A UL LISTED AMERICAN FLOW CONTROL, KENNEDY OR MUELLER VALVE THE SAME SIZE AS THE FIRE SERVICE LINE.8. MATERIAL AND INSTALLATION OF FIRE SERVICE LINE SHALL COMPLY WITH MPW, SEVENTH EDITION, COB MODS TO MPW, COB STANDARD DRAWINGS 02660-13, COB FIRE SERVICE LINESTANDARD, AND NFPA 24.9. ALL FITTINGS INCLUDING BENDS EQUAL TO OR GREATER THAN 22.5°, TEES AND PLUGS SHALL BE THRUST BLOCKED IN CONFORMANCE WITH MPWSS DETAIL 2660-1, OR MUST HAVEMECHANICALLY RESTRAINED JOINTS AS INDICATED ON THE PLANS.10. FDC, STROBE AND HORN TO BE INSTALLED ABOVE THE FDC ON THE EXTERIOR OF THE BUILDING BY INTERIOR SPRINKLER INSTALLERS.11. OS&Y VALVES AND RISERS THAT ARE INSTALLED PRIOR TO HAVING A HEATED BUILDING SHALL BE DRAINED BY THE CONTRACTOR TO PREVENT FREEZING AND THEN THE OS&Y SHALL BESEALED AND PROTECTED FROM CONTAMINATION. AN ADDITIONAL ROUND OF BAC-T TESTING WILL BE REQUIRED WHEN THE FIRELINE IS ACTIVATED AGAIN.12. THE LID OF THE FIRE SERVICE LINE VALVE BOX SHALL BE LABELED "FIRE".13. ADD V-BIO WRAP IF GEOTECH REPORT INDICATES SOIL IS CORROSIVE.THE FOLLOWING MINIMUM RESTRAINTLENGTH AT THE DUCTILE IRON FITTINGSAPPLY FOR ALL DUCTILE WATER MAINS,FIRE SERVICES AND WATER SERVICES.THE CALCULATIONS WERE COMPUTEDASSUMING 200 PSI TESTING PRESSURE.INSTALL 131' OF 4" CLASS 51D.I.P. FIRELINEEXISTING LIGHT POLELOT LINEINSTALL FIRE DEPARTMENTCONNECTION W/ STROBE & HORNHORIZONTAL SCALE: 1" = 10'VERTICAL SCALE: 1" = 1'11X17 HORIZ: 1" = 20'11X17 VERT: 1" = 2'LIVE TAP EXISTING 8" D.I.P.W/ 4" VALVESTA: 0+00ACTUAL LOCATION TO SHIFT IF NECESSARYTO MAINTAIN 2' OF SEPARATION FROM ANYEXISTING TAPS.INSTALL 4" - 45° HORIZONTAL BENDW/ MECHANICAL RESTRAINTSTA: 0+02INSTALL 4" 90° HORIZONTAL BENDW/ MECHANICAL RESTRAINTSTA: 0+58.5INSTALL 4" 45°HORIZONTAL BENDSTA: 1+13.75INSTALL 4" 90° VERTICAL BENDAND 4" OS&Y IN FIRE ROOMSTA: 1+31.00BTM OS&Y.: 4817.22FF ELEV: 4815.72WITH TYPE A BACKFILL, TYPE 1 BEDDING, TRACER WIRE, ANDDETECTABLE WARNING TAPE 18-24" BELOW THE SURFACEMIANTAIN 6.5' COVER, MINIMUM4" D.I.P. FIRE LINEEXISTING GROUNDFINISHED GRADEEXISTING SIGNS(REMOVE & REPLACEIF NECESSARY)VALVE BOX LABELED "FIRE"EXTENDED TO SURFACEAPPROXIMATE WATER SERVICEAPPROXIMATE SEWER SERVICEINSTALL 4" - 45° HORIZONTAL BENDW/ MECHANICAL RESTRAINTSTA: 0+13.5PROPOSED WATER SERVICEPROPOSED SEWER SERVICECONNECTION ELEVATION ISAPPROXIMATE,CONTRACTOR TO VERIFYBEFORE STARTINGCONSTRUCTION SO THATELEVATIONS CAN BEUPDATED ACCORDINGLY.RISER ROOM DETAIL 1"=5'OUTSWING DOOR4" OS& YFDC & ALARMNFOOTINGRECORD DRAWINGSJEREMY MAY, P.E.05/09/2023