Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
034 - C-1304 - ELECTRICAL SCHEDULES & DETAILS (2 OF 2)
2024COPYRIGHT © MORRISON-MAIERLE, SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DATEDESCRIPTIONNO.BY N:\6916\003 - TURNROW MASTER PLAN\ACAD\SHEETS\2-MASTER-SITE-PLAN\6916.003 - ELECTRICAL-DETAILS.DWGREVISIONS DRAWN BY: DSGN. BY: APPR. BY: DATE: Q.C. REVIEW DATE: BY: 2880 Technology Blvd West Bozeman, MT 59718 406.587.0721 www.m-m.net engineers surveyors planners scientists MorrisonMaierle VERIFY SCALE AND COLOR! THIS SHEET MAY BE REDUCED AND IS INTENDED TO BE IN COLOR. THE BAR BELOW WILL MEASURE ONE INCH AT ORIGINAL DESIGN SCALE AND RED, GREEN, AND BLUE WILL BE VISIBLE IFREPRODUCED CORRECTLY. MODIFY SCALE ACCORDINGLY! PLOTTED BY:MAYA SIMMONS ON Jul/29/2024 TURNROW SUBDIVISION MASTER SITE PLANBOZEMAN MONTANA ELECTRICAL SCHEDULES & DETAILS (2 OF 2) 6916.003 34 C-1304 PMH PMH JLG 07/24/2024 MASTER SITE PLAN JULY 2024 2"C TO LIGHTING PULLBOX2"C.O TO TRANSFORMER FINISHED GRADE NEMA 3R LIGHTING CONTROL ENCLOSURE WITH DEFINITE PURPOSE LIGHTING CONTACTORS CONTROLLED VIA POST TOP PHOTOCELL, TIMECLOCK (INTEGRAL TO METER PEDESTAL UNIT) AND HAND-OFF-AUTO SWITCH. CONTACTOR SHALL BE SIZED TO ACCOMMODATE ALL CIRCUITS ON LOAD CENTER METER BASE PEDESTAL WITH 120/240V, 1Ø 100A DISCONNECT PER UTILITY REQUIREMENTS. MILBANK, CP3B5111OA22SL1 WITH BASE: CP-16PDMNT-CALT INTEGRAL LOAD CENTER WITH 100A MAIN CIRCUIT BREAKER, (6) 20A/2P BREAKERS AND (4) 20A/1P BREAKERS CONCRETE BASE NOTE: CONTRACTOR SHALL PROVIDE 2-2" SPARE C.O. STUBBED TO OUTSIDE CONCRETE PAD. ALL METERING EQUIPMENT SHALL BE INSTALLED PER NWE STANDARDSGND PER NEC ARTICLE 250 PHOTOCELL MOUNTED ON RGS CONDUIT AT 8FT AFG SECURE CONDUIT TO SIDE OF METER PEDESTAL LB INTO SIDE OF PEDESTAL (1) 2" C.O. PER UTILITY REQUIREMENTS 120/240V, 1P, 3W, XFMR BY UTILTY 200A METER PEDESTAL SEE METERING EQUIPMENT DETAILS ON THIS SHEET TYPE I MINIMUM INSIDE DIMENSIONS W = 12 INCHES L = 18 INCHES D = 12 INCHES PULL BOX COMPOSITE 1" CLEAN STONE DRAINAGE CONCRETE SIDEWALK OR PAVERS CONDUIT IN PLACE AS REQUIRED. PROVIDE STUB 4-6" ABOVE BOTTOM OF PULL BOX AND CAP CONDUIT FOR FUTURE LUMINAIRES NOTES: FURNISH PULL BOXES AND COVERS MADE OF POLYMER CONCRETE WITH FIBERGLASS REINFORCEMENT. FURNISH PULL BOXES HAVING CONTINUOUS FIBERGLASS CLOTH REINFORCEMENT ON THE INSIDE AND OUTSIDE PERIMETERS. FURNISH COVERS HAVING A MINIMUM OF TWO LAYERS OF FIBERGLASS CLOTH REINFORCEMENT. ENSURE THE PULL BOXES AND COVERS COMPLY WITH ALL TEST PROVISIONS OF THE MOST CURRENT ANSI/SCTE 77 FOR TIER 22 APPLICATIONS. FURNISH PULL BOXES AND COVERS THAT HAVE BEEN TESTED AND CERTIFIED BY A NATIONALLY RECOGNIZE D THIRD PARTY INDEPENDENT TEST FIRM SUCH AND UL OR ETL VERIFYING THAT THE BOXES AND COVERS MEET ALL TEST PROVISIONS OF THE ANSI/SCTE 77. FURNISH PULL BOXES THAT HAVE MARKINGS SHOWING THE TIER 22 RATING LABELED OR STENCILED ON THE INSIDE AND OUTSIDE OF THE BOX. FURNISH COVERS THAT MARKING SHOWING THE TIER 22 RATING EMBOSSED IN THE TOP SURFACE OF THE COVER. FURNISH COVERS HAVING PULL SLOTS RATED FOR A MINIMUM PULL OUT OF 3,000 POUNDS. FURNISH 3/8-7 LAB THREAD HEX HEAD BOLTS TO SECURE THE COVER TO THE PULL BOX. LIGHTING HOLD DOWN BOLTS 1 E-4 PULL BOX DETAIL SCALE: NONE 2 E-4 ONE-LINE DIAGRAM SCALE: NONE 3 E-4 M1 METERING EQUIPMENT DETAIL SCALE: NONE CONTRACTOR TO COORDINATE FINAL LOCATION WITH UTILITY MO N T N A PROFESSIONAL E N G IN EERJACOB L. GARWOOD No. 87191 PE LICEN DES A 11/10/2023 4 E-4 M2 METERING EQUIPMENT DETAIL SCALE: NONE SIDE FRONT NEMA 3R CABINET 2" CONDUIT BODY 2" RIGID STEEL CONDUIT WIRING AS REQUIRED 120/240 VOLT UNDERGROUND SERVICE CONDUIT & WIRING AS REQUIRED 6" X 6" PRESSURE TREATED WOOD POST 10' LENGTH SERVICE RATED 200 AMP METER MAIN 2" RIGID STEEL CONDUIT 3/4" SCHED. 80 PLASTIC CONDUIT 1 BARE NO. 8 AWG 5/8" COPPERWELD GROUND ROD METER M3 WITH 20A MCB FOR TRAFFIC SIGNAL MOUNTED LUMINAIRES METER M2 WITH 60A MCB FOR TRAFFIC SIGNAL CONTROLLER 034