031 - C-1301 - ELECTRICAL NOTES
2024COPYRIGHT © MORRISON-MAIERLE, SHEET NUMBER PROJECT NUMBER DRAWING NUMBER DATEDESCRIPTIONNO.BY N:\6916\003 - TURNROW MASTER PLAN\ACAD\SHEETS\2-MASTER-SITE-PLAN\6916.003 - ELECTRICAL-DETAILS.DWGREVISIONS DRAWN BY: DSGN. BY: APPR. BY: DATE: Q.C. REVIEW DATE: BY: 2880 Technology Blvd West Bozeman, MT 59718 406.587.0721 www.m-m.net engineers surveyors planners scientists MorrisonMaierle VERIFY SCALE AND COLOR! THIS SHEET MAY BE REDUCED AND IS INTENDED TO BE IN COLOR. THE BAR BELOW WILL MEASURE ONE INCH AT ORIGINAL DESIGN SCALE AND RED, GREEN, AND BLUE WILL BE VISIBLE IFREPRODUCED CORRECTLY. MODIFY SCALE ACCORDINGLY! PLOTTED BY:MAYA SIMMONS ON Jul/29/2024 TURNROW SUBDIVISION MASTER SITE PLANBOZEMAN MONTANA ELECTRICAL NOTES 6916.003 31 C-1301 PMH PMH JLG 07/24/2024 MASTER SITE PLAN JULY 2024 ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTIONS MOUNTING HEIGHT, UNO BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL WITH CIRCUITS AS NOTED. WIRE SIZE IS #12 UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE CONDUCTORS. LONG TICK MARKS INDICATE NEUTRAL CONDUCTORS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT. A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDED WITH EACH HOME RUN. RACEWAY BELOW FLOOR OR BELOW GRADE RACWAY STUB-OUT OR STUB-UP WITH BUSHED END PAD MOUNTED TRANSFORMER UTILITY ELECTRIC METER SEE DETAIL SHEET E-4 METER LINE BREAK HANDHOLE SEE DETAIL SHEET E-4 KEY NOTE. REFER TO SPECIFIC NOTE ON SAME DRAWING SHEET. POLE MOUNTED LUMINAIRE ASSEMBLY SECURED TO CONCRETE BASE. LETTER INDICATES FIXTURE TYPE. PHOTOCELL DUPLEX RECEPTACLE.18" SPECIAL PURPOSE OUTLET, LETTER INDICATES TYPE. SEE SPEC.18" JUNCTION BOX FUSED DISCONNECT SWITCH BRANCH CIRCUIT PANELBOARD BREAKER CONTACTOR 1. THESE SYMBOLS COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT. 2. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR. MOUNTING HEIGHTS INDICATED ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED. P-1,3,5 M M HH 1 P A J C ABBREVIATIONS A or AMP AMPERESACALTERNATING CURRENTA/C AIR CONDITIONINGAFAMP FUSEAFFABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AL ALUMINUM AS AMP SWITCH BAS BUILDING AUTOMATION SYSTEMBKRBREAKER C RACEWAY/CONDUIT CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISIONCKTCIRCUITC.O.RACEWAY/CONDUIT ONLY, WITH PULL STRING CNTRL CONTROL CU COPPER DISC DISCONNECTDISTDISTRIBUTIONDPDTDOUBLE POLE DOUBLE THROWDWGDRAWING EA EACH EF EXHAUST FAN ELEC ELECTRIC EMT ELECTRICAL METALLIC TUBINGEQUIPEQUIPMENT EX OR EXIST EXISTING FD FUSED DISCONNECTFLRFLOORFOFIBER OPTICFVNRFULL VOLTAGE NON-REVERSINGFVRFULL VOLTAGE REVERSING GEC GROUNDED ELECTRODE CONDUCTOR GFI GROUND FALUT INTERRUPTERGNDGROUNDGRCGALVANIZED RIGID CONDUIT HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTOMATIC HP HORSEPOWER HPS HIGH PRESSURE SODIUMHTRHEATERHZHERTZ J-BOX JUNCTION BOX KVA KILOVOLT AMPERES KW KILOWATTS LTG LIGHTING MAX MAXIMUM MH METAL HALIDE MIN MINIMUM N NEUTRALNCNORMALLY CLOSEDNECNATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NFD NON-FUSED DISCONNECT NIC NOT IN CONTRACT NO NORMALLY OPEN #NUMBER OC ON CENTEROHOVERHEAD P POLE PB PUSHBUTTON PNL PANEL PVC POLYVINYL CHLORIDE CONDUITPWRPOWER RECEPT RECEPTACLERGSRIGID GALVANIZED STEEL RM ROOM RVNR REDUCED VOLTAGE NON-REVERSING RVR REDUCED VOLTAGE REVERSING SP SINGLE POLE TOGGLE SWITCHSPECSPECIFICATION SPST SINGLE POLE SINGLE THROW SSPB START-STOP PUSHBUTTON SW SWITCH TC TIME CLOCKTDTIME DELAYTSPTWISTED SHIELDED PAIRTTBTELEPHONE TERMINAL BOARD TYP TYPICAL UG UNDERGROUNDUHUNIT HEATERUNOUNLESS NOTED OTHERWISEUONUNLESS OTHERWISE NOTED V VOLT VA VOLT AMPERES W WATTSWPWEATHERPROOFW/O WITHOUT XFMR TRANSFORMER Y WYE CONNECTED DELTA CONNECTED PHASE *THESE ABBREVIATIONS COMPRISE A STANDARD LIST; NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT. 1.PRIOR TO BID CONTRACTOR SHALL VISIT THE SITES. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID. 2.GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NCSA BY TELEPHONE AT 301-215-4521 OR ON-LINE AT WWW.NECA-NEIS.ORG. 3.ALL POLES AND METER BASES SHALL BE LOCATED MINIMUM 3' FROM BACK OF CURB. COMPLY WITH CITY OF BOZEMAN DESIGN STANDARDS AND COORDINATE EXACT LOCATION WITH CIVIL DRAWINGS PRIOR TO ROUGH-IN. 4.ALL NEW POLES SHOULD BE PROVIDED WITH BREAKAWAY BOLTS. PROVIDE TRANSPO POLE-SAFE MODEL 4100 OR EQUAL. 5.CONTRACTOR SHALL BORE/DIRECT BURY UNDER ROADWAYS, DRIVEWAYS, SIDEWALKS, ETC. ALL COSTS ASSOCIATED WITH BORING/DIRECT BURY SHALL BE INCLUDED IN CONTRACTOR'S BID PRICE. 6.CONTRACTOR TO IMMEDIATELY NOTIFY ENGINEER AND OWNER OF ANY CONFLICTS ENCOUNTERED DURING CONSTRUCTION. UNDER NO CIRCUMSTANCES SHALL CONTRACTOR RESOLVE CONFLICT PRIOR TO NOTIFICATION. 7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL ELECTRICAL SERVICE WORK WITH NORTHWESTERN ENERGY. OWNER PAYS ALL FEES, CONTRACTOR DOES ALL SCHEDULING AND COORDINATION OF NORTHWESTERN ENERGY WORK. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALL SCHEDULES ARE MET. PROJECT NOTES INCOMING ELECTRICAL SERVICE DIVISION OF RESPONSIBILITY ELEC. CONTR. UTILITY CO. PRIMARY CONDUIT X PRIMARY CONDUCTORS X POLE MOUNT TRANSFORMER X POLE RISER X TRANSFORMER CONNECTIONS X SECONDARY CONDUIT X SECONDARY CONDUCTORS X DISCONNECT X METER BASE X METER X NOTES: 1. CONTACT AND COORDINATE ALL REQUIREMENTS AND RESPONSIBILITIES WITH SERVING UTILITY COMPANIES PRIOR TO SUBMITTING BID 2. ALL SERVICE INSTALLATION WORK SHALL BE IN STRICT COMPLIANCE WITH THE REQUIREMENTS OF THE SERVING UTILITIES. POWER CONTACT: AIDAN MURRAY NORTHWESTERN ENERGY BOZEMAN, MT (406) 370-9164 MORRISON MAIERLE, INC. HAS CONTACTED THE UTILITIES BUT HAS NOT RECEIVED IN WRITING THE FINAL REQUIREMENTS FROM THE POWER UTILITY. THESE DRAWINGS INDICATE OUR BEST ESTIMATION OF THEIR REQUIREMENTS. PRIOR TO BID CONTACT THE UTILITIES AND OBTAIN IN WRITING THEIR REQUIREMENTS.MO N T N A PROFESSIONAL E N G IN EERJACOB L. GARWOOD No. 87191 PE LICEN DES A 11/10/2023 031