Loading...
HomeMy WebLinkAbout025_ParkingGSFCalculationsLATSPSF MUH-2 T F F F BD UP A201 3 1 1 A A 2 2 3 3 4 4 5 5 6 6 7 7 F FREF. TO PEMB FOR MTL BUILDING DIMS1 A301 __________ A201 2 A201 1 A201 4 7113 SF SHOP FLOOR 101 1131 SF STORAGE 103324 SF MECH 102 205 SF BREAK ROOM 104 195 SF OFFICE 107 68 SF R.R. 106 66 SF R.R 105 REF. TO PEMB FOR MTL BUILDING DIMS REF. TO PEMB FOR MTL BUILDING DIMSREF. TO PEMB FOR MTL BUILDING DIMS 2 A301 __________ 3 A301 __________ IW2-4 107A 106A105A104A 103A 101B101A 108A 103B 101C101D101EB B D D E E C VEHICLE LIFT, BY OWNER VEHICLE LIFT, BY OWNER OVHD, BY OWNER OVHD, BY OWNEROVHD, BY OWNEROVHD, BY OWNER 102B 102A 82 SF HALL 108 IW1-4 IW2-4 IW2-4 IW2-4 IW2-4 IW2-4 IW1-4 10' - 6"9' - 6"IW2-6 IW2-4 DOOR BY PEMB OVHD, BY OWNER DOOR BY PEMB OVHD, BY OWNER 17' - 5"2' - 7"17' - 6"2' - 6"17' - 0"3' - 0" B B EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB A401 1 4 A301 __________ FE FE FE 11' - 0"9' - 0"1' - 2"18' - 10" EMERGENCY FLOOR DRAIN TRENCH DRAIN, REF MEP REF MEP EMERGENCY SHOWER, REF MEP A411 3 IW2-4 DOWNSPOUT BY PEMB, TYP. STL PIPE BOLLARD STL PIPE BOLLARD WH E A T D RIV E KEYPLAN PLAN NORTH 1 1 A A 2 2 3 3 4 4 5 5 6 6 7 7 1 A301 __________ 5' - 0" 5' - 0"10' - 0"5' - 0" OPEN TO BELOW 3 A301 __________ A421 1 PRE-FABRICATED MANUAL HORIZONTAL MEZZANINE SAFETY GATE B B C C A A A A A A A A A A MEZZANINE 201 A A IW2-4 4' - 0"IW2-4 4' - 0" IW2-4 4' - 0"23' - 8"REF. TO PEMB FOR MTL BUILDING DIMS 20' - 0"EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB 4 A301 __________ FE FE DN KALWALL DOWNSPOUT BY PEMB, TYP. A500 3 GENERAL SHEET NOTES A. PROVIDE FIRE EXTINGUISHERS AND FIRE EXTINGUISHER CABINETS AS SHOWN / SPECIFIED. COORDINATE FINAL LOCATIONS WITH FIRE MARSHALL. B. SEE A003 FOR ALL PARTITION AND WALL ASSEMBLY TYPES. ALL FRAMING AND FINISHES OF INTERIOR WALLS TO EXTEND TO THE UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE. C. SEE A001 FOR DETAILED INFORMATION ON DIMENSIONING D. DASHED BOXES AND CIRCLES SHOW CLEAR FLOOR AREA. DASHED AREAS ARE FOR REFERENCE AND NOT ALL ARE SHOWN E. CONTRACTOR TO COORDINATE ADDITIONAL FRAMING WITH EXTERIOR CLADDING ATTACHMENTS AND FASTENERS F. FOR DOOR OPENING DIMENSIONS SEE DOOR SCHEDULE IN A600 SHEETS G. SEE A600 SHEETS FOR FINISH SCHEDULE H. ABBREVIATIONS: REFERENCED FROM THE CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM TERMS AND ABBREVIATIONS MODULE. REFER TO SHEET A001 - ARCHITECTUAL GENERAL NOTES. I. CONTRACTOR TO FEILD VERIFY ALL FOUNDATION AND FOOTING HEIGHTS. J. CONTRACTOR TO COORDINATE ALL SITE DRAINAGE. K. ALL STRUCTURAL ELEMENTS ARE TO BE REVIEWED BY A LICENSED STRUCTURAL ENGINEER. L. EXTERIOR BUILIDNG DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR F.O. SHEATHING/OUTSIDE FACE OF FOUNDATION. M. DIMENSIONS ARE TO GRID CENTERLINE, FACE OF CONCRETE WALL OR FACE OF STUD AS APPLICABLE, UNLESS NOTED OTHERWISE N. ALL INTERIOR DOORS ARE 4 1/2" AWAY FROM ADJACENT PERPINDICULAR STUD , UNLESS SPECIFICALLY DIMENSIONED. O. CONTRACTOR TO COORDINATE ALL HVAC. COORDINATE WITH ARCHITECT FOR ANY FLOOR PLAN CHANGES. P. CONTRACTOR TO COORDINATE ALL ELECTRICAL REQUIREMENTS. Q. CONTRACTOR TO COORDINATE ALL STRUCTURAL SHEAR REQUIREMENTS W/ A LICENSED STRUCTURAL ENGINEER. R. REFER TO ARCHITECTURAL SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL MATERIAL TYPES, LOCATIONS, AND EXTENTS. S. COORDINATE T.O. FOUNDATION WALL AND FINISH FLOORING WITH NEW GRADE. Date Project Number Sheet Name ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE REVISIONS ALL DRAWN AND WRITTEN INFORMATION APPEARING ON THIS DRAWING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE.MARK DESCRIPTION DATE 4/23/2024 4:37:14 PMA101 FLOOR PLANSSIMKINS LUMBER MECHANIC SHOP04.22.2024 23009SIMKINS NORTH PARK TRACT 3-BWHEAT DRIVEBOZEMAN, MT 59715CONSTRUCTION DOCUMENTS 1/8" = 1'-0"A101 1 LEVEL 1 FLOOR PLAN PLAN NORTH 1/8" = 1'-0"A101 2 MEZZANINE FLOOR PLAN JFSTSRH-1 RH-2T TRH-7 RH-8 RH-3 RH-4T RH-9 RH-10T RH-5 RH-6 T UH-4 T A201 1 1 1 A A 2 2 3 3 4 4 5 5 7 7 8 8 9 9 10 10 E E G G L L 4 A301 __________4 A301 __________ A201 4 A201 3 A201 2 N N 12 12 REF. TO PEMB FOR MTL BUILDING DIMS REF. TO PEMB FOR MTL BUILDING DIMSREF. TO PEMB FOR MTL BUILDING DIMS 3 A301 __________ 3 A301 __________REF. TO PEMB FOR MTL BUILDING DIMSA401 5 101C101F101G101D101I101J101K101E101A 101B102A102B101HB B C C K K M M J J 6 11 109BEW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB EW1 BY PEMB 3' - 0"22' - 0"6' - 6"18' - 6"21' - 2"3' - 10"14' - 6"3' - 0"16' - 6"8' - 6"21' - 2"3' - 10"17' - 8"7' - 4"DOOR BY PEMB DOOR BY PEMB DOOR BY PEMBOVHD ROLLUP DOOR DOOR BY PEMBDOOR BY PEMB DOOR BY PEMB 5 A301 __________5 A301 __________1' - 0" CLEAR FROM MTL COLUMN8.17% 1.50% CONC. LOADING RAMP, REF CIVIL CONC. LANDING STRIP, REF CIVIL 1.50% CONC. LANDING STRIP, REF CIVIL DN DN GLASS SHOP 102 MILLWORK STORAGE 101 A601 3 A601 16 A502 __________ PREMANUF GUARD RAIL PREMANUF GUARD RAIL D D H H STL PIPE BOLLARD W H E A T D RIV E R AIL R O A D KEYPLAN PLAN NORTH GENERAL SHEET NOTES A. PROVIDE FIRE EXTINGUISHERS AND FIRE EXTINGUISHER CABINETS AS SHOWN / SPECIFIED. COORDINATE FINAL LOCATIONS WITH FIRE MARSHALL. B. SEE A003 FOR ALL PARTITION AND WALL ASSEMBLY TYPES. ALL FRAMING AND FINISHES OF INTERIOR WALLS TO EXTEND TO THE UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE. C. SEE A001 FOR DETAILED INFORMATION ON DIMENSIONING D. DASHED BOXES AND CIRCLES SHOW CLEAR FLOOR AREA. DASHED AREAS ARE FOR REFERENCE AND NOT ALL ARE SHOWN E. CONTRACTOR TO COORDINATE ADDITIONAL FRAMING WITH EXTERIOR CLADDING ATTACHMENTS AND FASTENERS F. FOR DOOR OPENING DIMENSIONS SEE DOOR SCHEDULE IN A600 SHEETS G. SEE A600 SHEETS FOR FINISH SCHEDULE H. ABBREVIATIONS: REFERENCED FROM THE CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM TERMS AND ABBREVIATIONS MODULE. REFER TO SHEET A001 - ARCHITECTUAL GENERAL NOTES. I. CONTRACTOR TO FEILD VERIFY ALL FOUNDATION AND FOOTING HEIGHTS. J. CONTRACTOR TO COORDINATE ALL SITE DRAINAGE. K. ALL STRUCTURAL ELEMENTS ARE TO BE REVIEWED BY A LICENSED STRUCTURAL ENGINEER. L. EXTERIOR BUILIDNG DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR F.O. SHEATHING/OUTSIDE FACE OF FOUNDATION. M. DIMENSIONS ARE TO GRID CENTERLINE, FACE OF CONCRETE WALL OR FACE OF STUD AS APPLICABLE, UNLESS NOTED OTHERWISE N. ALL INTERIOR DOORS ARE 4 1/2" AWAY FROM ADJACENT PERPINDICULAR STUD , UNLESS SPECIFICALLY DIMENSIONED. O. CONTRACTOR TO COORDINATE ALL HVAC. COORDINATE WITH ARCHITECT FOR ANY FLOOR PLAN CHANGES. P. CONTRACTOR TO COORDINATE ALL ELECTRICAL REQUIREMENTS. Q. CONTRACTOR TO COORDINATE ALL STRUCTURAL SHEAR REQUIREMENTS W/ A LICENSED STRUCTURAL ENGINEER. R. REFER TO ARCHITECTURAL SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL MATERIAL TYPES, LOCATIONS, AND EXTENTS. S. COORDINATE T.O. FOUNDATION WALL AND FINISH FLOORING WITH NEW GRADE. Date Project Number Sheet Name ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE REVISIONS ALL DRAWN AND WRITTEN INFORMATION APPEARING ON THIS DRAWING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE.MARK DESCRIPTION DATE 4/23/2024 2:08:15 PMA101 FIRST FLOOR PLANSIMKINS MILLWORK BUILDING04.22.2024 23009SIMKINS NORTH PARK TRACT 3-BWHEAT DRIVEBOZEMAN, MT 59715CONSTRUCTION DOCUMENTS 1/16" = 1'-0"A101 1 LEVEL 1 FLOOR PLAN PLAN NORTH