Loading...
HomeMy WebLinkAbout049_ES001_ElectricalDetails25' AFG MAST ARM 4' SINGLE MEMBER TYPE MASTARM 30" BASE FINISHED GRADE BASE SIZE SEE SCHED.2'-6"HEIGHT AFGSEE SCHED.DEPTH *** - SEE SCHED. CONCRETE BASE SCHEDULE ** POLE HT.BASE SIZE VERT. REINF. TRANSVERSE REINF.** DEPTH *** HEIGHT AFG 14' TO 30'24" RND.(6) #6 *#3@8" O.C.7'-0" 2'-6" ANCHOR BOLTS FROM POLE MANF. NOTE: TRANSVERSE REINF. SEE SCHEDULE HANDHOLE - 4" X 6" (NOMINAL) THWN CONDUCTOR AS SHOWN ON PLANS PROVIDE 1' OF COILED SLACK ON CONDUCTOR FEED THRU PROJECT ANCHOR BOLTS 3" MIN. ABOVE TOP OF BASE. PROVIDE DOUBLE NUTS FOR LEVELING UNIT (ONE ABOVE AND ONE BELOW BASE FLANGE). PROVIDE NON-SHRINK GROUT IN VOID BETWEEN BASE FLANGE AND TOP OF CONCRETE, LEAVING DRAIN HOLE. HAND FINISH. CONNECT GROUND TO POLE BASE W/ BOUNDARY #GB4C PROVIDE FUSE(S) IN CKT. TO BALLAST. FUSE(S) SHALL BE BUSS TYP. BBS. FUSE HOLDERS SHALL BE BUSS "TRON" HEB WATERPROOF. SIZE OF FUSE SHALL BE AS REQUIRED BY LUMINAIRE MANUFACTURER. BASE COVER BUSH CONDUITS REINFORCED CONC. PIER FOOTING BY ELECTRICAL CONTRACTOR 1" CHAMFER SEE SITE PLAN FOR CONDUIT SIZE FINISH GRADE. BACKFILL & COMPACT AS RECOMMENDED BY GEOTECHNICAL ENGINEER VERT. REINF. SEE SCHEDULE NOTE: • CONTRACTOR SHALL GRIND EXPOSED CONCRETE SMOOTH AS REQUIRED TO REMOVE ANY FORMWORK MARKINGS. * SPACE VERTICAL BARS EVENLY AROUND PERIMETER. ** PROVIDE REINF. CLEARANCE AND COVER PER ACI 318. Date Project Number Sheet Name ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE NOT FOR CONSTRUCTION REVISIONS MARK DESCRIPTION DATE ES001 ELECTRICAL DETAILSSIMKINS-HALLIN TRACT 3-B01.31.2024 6088.013WHEAT DRIVEBOZEMAN, MTSITE PLAN SUBMITTAL LUMINAIRE SCHEDULE TYPE LAMPS LOAD (W) OUTPUT (LM, NOMINAL) CCT (K)DESCRIPTION MFR CATALOG NO. OR SERIES MOUNTING VOLTAGE NOTES E1 LED 24 W 2,900 4000K EXTERIOR WALL PACK WITH BATTERY PACK FOR EGRESS DOORS LITHONIA WPX1LEDP2-40K-MVOLT-E14WC-DDBXD WALL 120 V E2 LED 47 W 6,000 4000K EXTERIOR WALL PACK WITH BATTERY PACK FOR GARAGE DOORS/SITE LIGHTING LITHONIA WPX2LED-40K-MVOLT-E14WC-DDBXD WALL 120 V P1 LED 181 W 24,272 2700K SINGLE-HEAD POLE-MOUNT SITE LIGHT, TYPE 4 LITHONIA DSX2-P2-27K-80CRI-T4M-MVOLT-RPA-D DBXD 25' ROUND POLE 277 V 6 1. PRIOR SUBMITTAL NOT REQUIRED. ALL ALTERNATE FIXTURE SHOP DRAWINGS WILL BE REVIEWED AFTER THE PROJECT IS AWARDED. 2. PRIOR SUBMITTAL IS REQUIRED. 3. ALTERNATE FIXTURE IS NOT ACCEPTED FOR SUBSTITUTIONS. 4. PROVIDE 0-10V DIMMING, DOWN TO 10% LUMEN OUTPUT, MINIMUM. 5. PROVIDE FUSING. 6. VERIFY FINISH WITH ARCHITECT. 7. PROVIDE WITH REMOTE 12V STEP-DOWN TRANSFORMER. 8. CIRCUIT VIA TYPE EM INVERTER. 9. LAMP DATA IS FOR 4' CROSS-SECTION OF FIXTURE. 10.MOUNT BOTTOM OF FIXTURE CENTERED AT 6” ABOVE TOP OF MIRROR. SEE ARCHITECT ELEVATIONS. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND PROVIDE ALL MOUNTING, FIRE-RATED, AND IC-RATED ACCESSORIES AS REQUIRED. FOR FIRE-RATED CEILING ASSEMBLIES AND FOR CEILINGS WITH INSULATION, VERIFY ALL RECESSED LUMINAIRE HOUSINGS ARE RATED APPROPRIATELY OR PROVIDE DROP-OVER ENCLOSURES OR TENTS FOR LUMINAIRES. VERIFY THAT DROP-OVER ENCLOSURES OR TENTS ALLOW FOR AIR SPACE AROUND LUMINAIRE PER MANUFACTURER'S RECOMMENDATIONS. NOTES:GENERAL NOTE: N.T.S.2 POLE LIGHT HEIGHT DETAIL -EXTENDED MAST ARM N.T.S.1 POLE LIGHT BASE DETAIL