Loading...
HomeMy WebLinkAbout041_A102_RoofPlanA201 1 1 1 A A 2 2 3 3 4 4 5 5 7 8 8 9 9 10 10 E E G G L L A201 4 A201 3 A201 2 N N 12 12 B B C C K K M M J J 6 6 11 1" / 12"1" / 12" 1" / 12" 180' - 0"40' - 0"23' - 8"77' - 8"123' - 8"180' - 0"40' - 0"225' - 0"220' - 0" 220' - 0" 1" / 12" 1" / 12"225' - 0"23' - 0"54' - 0"96' - 0"52' - 0"1/2"D D H H 2 A102 TYP. __________ 3 A102 TYP. __________1" / 12"GENERAL SHEET NOTES A. PROVIDE FIRE EXTINGUISHERS AND FIRE EXTINGUISHER CABINETS AS SHOWN / SPECIFIED. COORDINATE FINAL LOCATIONS WITH FIRE MARSHALL. B. SEE A003 FOR ALL PARTITION AND WALL ASSEMBLY TYPES. ALL FRAMING AND FINISHES OF INTERIOR WALLS TO EXTEND TO THE UNDERSIDE OF STRUCTURE ABOVE UNLESS NOTED OTHERWISE. C. SEE A001 FOR DETAILED INFORMATION ON DIMENSIONING D. DASHED BOXES AND CIRCLES SHOW CLEAR FLOOR AREA. DASHED AREAS ARE FOR REFERENCE AND NOT ALL ARE SHOWN E. CONTRACTOR TO COORDINATE ADDITIONAL FRAMING WITH EXTERIOR CLADDING ATTACHMENTS AND FASTENERS F. FOR DOOR OPENING DIMENSIONS SEE DOOR SCHEDULE IN A600 SHEETS G. SEE A600 SHEETS FOR FINISH SCHEDULE H. ABBREVIATIONS: REFERENCED FROM THE CONSTRUCTION SPECIFICATIONS INSTITUTE'S UNIFORM DRAWING SYSTEM TERMS AND ABBREVIATIONS MODULE. REFER TO SHEET A001 - ARCHITECTUAL GENERAL NOTES. I. CONTRACTOR TO FEILD VERIFY ALL FOUNDATION AND FOOTING HEIGHTS. J. CONTRACTOR TO COORDINATE ALL SITE DRAINAGE. K. ALL STRUCTURAL ELEMENTS ARE TO BE REVIEWED BY A LICENSED STRUCTURAL ENGINEER. L. EXTERIOR BUILIDNG DIMENSIONS ARE TO GRID CENTERLINE, EXTERIOR F.O. SHEATHING/OUTSIDE FACE OF FOUNDATION. M. DIMENSIONS ARE TO GRID CENTERLINE, FACE OF CONCRETE WALL OR FACE OF STUD AS APPLICABLE, UNLESS NOTED OTHERWISE N. ALL INTERIOR DOORS ARE 4 1/2" AWAY FROM ADJACENT PERPINDICULAR STUD , UNLESS SPECIFICALLY DIMENSIONED. O. CONTRACTOR TO COORDINATE ALL HVAC. COORDINATE WITH ARCHITECT FOR ANY FLOOR PLAN CHANGES. P. CONTRACTOR TO COORDINATE ALL ELECTRICAL REQUIREMENTS. Q. CONTRACTOR TO COORDINATE ALL STRUCTURAL SHEAR REQUIREMENTS W/ A LICENSED STRUCTURAL ENGINEER. R. REFER TO ARCHITECTURAL SHEET SERIES 200 EXTERIOR ELEVATIONS FOR THE IDENTIFICATION OF VARIOUS EXTERIOR WALL MATERIAL TYPES, LOCATIONS, AND EXTENTS. S. COORDINATE T.O. FOUNDATION WALL AND FINISH FLOORING WITH NEW GRADE.WH E A T D RIV E KEYPLAN PLAN NORTH MTL PNL, REF PEMB NOTE:REFERENCE PEMB SET FOR CONSTRUCTION DETAIL MTL GUTTER, BY PEMB MTL PNL, REF PEMB PANEL CLOSURE, REF MFG MTL GUTTER BRACKET, BY PEMB STL FRAMING, REF PEMB FILL WITH INSULATION SHT MTL FLASH VINYL LINED BATT INSULATION GRID MTL PNL, REF PEMB PANEL CLOSURE, REF MFG MTL SCULPTURED RAKE BY PEMB STL FRAMING, REF PEMB FILL CAVITY WITH INSULATION MTL PNL, REF PEMB NOTE:REFERENCE PEMB SET FOR CONSTRUCTION DETAIL 2 1/4" MASTIC TAPE BY PEMB VINYL LINED BATT INSULATION GRID Date Project Number Sheet Name ALL DRAWN AND WRITTEN INFORMATION APPEARING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE REVISIONS ALL DRAWN AND WRITTEN INFORMATION APPEARING ON THIS DRAWING SHALL NOT BE DUPLICATED, DISCLOSED OR OTHERWISE USED WITHOUT THE WRITTEN CONSENT OF 45 ARCHITECTURE.MARK DESCRIPTION DATE 6/13/2024 9:35:29 AMA102 ROOF PLANSIMKINS MILLWORK BUILDING04.22.2024 23009SIMKINS NORTH PARK TRACT 3-BWHEAT DRIVEBOZEMAN, MT 59715CONSTRUCTION DOCUMENTS 1/16" = 1'-0"A102 1 ROOF PLAN PLAN NORTH 1 1/2" = 1'-0"A102 2 EAVE GUTTER DETAIL 1 1/2" = 1'-0"A102 3 RAKE SCULPTURED DETAIL 1 Site Plan Submittal 06.14.24