HomeMy WebLinkAbout037_L4.1_IrrigationDetails FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONa sanderson bellecci companyWHEAT DRIVEIRRIGATION DETAILSSIMKINS-HALLIN TRACT 3-BNORTH PARK SIMKINS-HALLIN SITE DEVELOPMENTBOZEMAN, MTL4.1 TP21363_01_IR_DETAILS_T3-B.DWGCS/KA01/31/24SITE PLAN SUBMITTAL06/14/24-----SITE PLAN SUBMITTAL-------21363.01FROM WATER
SOURCE
TO IRRIGATION
SYSTEM
GROUND LEVEL
ZURN 375 BACKFLOW PREVENTOR
OR APPROVED EQUAL
BLOWOUT TEE WITH CAP
COPPER PIPE
MAIN LINE
(PVC PIPE)
COPPER PIPE 1.5' MININTERIOR POINT OF CONNECTION
N.T.S.
WALL MOUNT BRACKETS
NOTES:
1.POINT OF CONNECTION SHALL BE INSIDE MECHANICAL
ROOM OF BUILDING.
2.VALVES SHALL BE WALL MOUNTED WITH APPROPRIATE
BRACKETS.
PRESSURE REDUCING VALVE RAIN BIRD
PSI-H50X-100 OR APPROVED EQUAL
RAIN BIRD UFS-150 FLOW SENSOR OR
APPROVED EQUAL
1 CONTROLLER - WALL MOUNT
N.T.S.
13" OPEN DOOR WIDTH
5"
ELECTRICAL SUPPLY CONDUIT
CONNECT TO POWER SOURCE,
J-BOX INSIDE CONTROLLER
ADJACENT SURFACE TO MOUNT
CONTROLLER PER PLAN ADJACENT SURFACE TO
MOUNT CONTROLLER PER
PLAN
IRRIGATION CONTROL
WIRE IN CONDUIT
SIZE AND TYPE PER
LOCAL CODES
IRRIGATION
CONTROLLER
NOTES:
1.MOUNT CONTROLLER LCD SCREEN AT EYE LEVEL.
2.CONTROLLER SHALL BE HARD-WIRED TO
GROUNDED 110 VAC POWER SOURCE.
RIGHT ELEVATION
FRONT ELEVATION
2
18"
PLANS
SECTIONS
DIRECT BURY PLAN
DIRECT BURY SECTION
TAPE & BUNDLE ALL WIRING AT 10' INTERVALS.
USE 6" WIDE MARKING TAPE 6" ABOVE ALL
DIRECT BURIAL WIRING.
ALL SPLICES SHALL BE MADE IN VALVE BOXES
AND LOCATED ON AS-BUILT PLANS (ALL 120 V).
WIRING SHALL BE IN CONDUIT WITH MARKER
TAPE AS ABOVE.
ALL WIRING UNDER PAVEMENT & THROUGH
SLEEVES SHALL BE IN CONDUIT. TIE A LOOSE 20
INCH LOOP IN WIRING AT ALL CHANGES IN
DIRECTION GREATER THAN 30 DEGREES. UNTIE
ALL LOOPS AFTER MAKING CONNECTIONS.
18"
CONDUIT SECTION
CONDUIT PLAN
24" 36" 24" 36"
LATERAL PIPE IN
TRENCH SNAKE ALL
FINISHED GRADE
MARKING TAPE
LOOP
TIES
FINISHED GRADE
LATERAL
MAIN LINE
BEDDING
LOW VOLTAGE WIRE OR 120V WIRE IN CONDUIT
LATERAL
TRENCHING DETAILS
N.T.S.3
STANDARD VALVE BOX
UPSIDE DOWN
GRAVEL
STANDARD VALVE BOX
VALVE
FINISHED GRADE
NOTES:
1.VALVE BOXES SHALL BE SCREWED TOGETHER.
2.VALVE BOXES WILL BE LEVEL WITH FINISH GRADE.
3.INSTALLATION PER DETAIL WILL PREVENT SETTLING,
DETER RODENTS FROM NESTING, AND PRESERVE VALVE
AND IRRIGATION LINES.
DOUBLE VALVE BOX
N.T.S.4
1'
VALVE BOXES TO BE
ALIGNED AND EVENLY
SPACED
VALVE BOX PLACEMENT
N.T.S.
TURF
VALVE LID TO BE
BRANDED WITH
CONTROLLER AND
STATION NUMBERS
NOTES:
1.WHEN MULTIPLE VALVES ARE WITHIN A SMALL
PROXIMITY THE CONTRACTOR SHALL DETERMINE IF
BEST TO USE ONE LARGE VALVE BOX AND GANG
VALVES TOGETHER.
5
AGGREGATE
SHUT OFF VALVE
IRRIGATION
MAIN LINE
VALVE BOX
FLOW CONTROL VALVE
N.T.S.6
10" ROUND VALVE BOX BRAND
"QC" INTO VALVE BOX
FINISHED GRADE
3/4" CRUSHED GRAVEL ROCK
SUMP - 1 CU. FT
QUICK COUPLING VALVE
WEED BARRIER FABRIC
1" PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
QUICK COUPLER
VALVE STABILIZER
1" PVC SCH 80 FIPxFIP
90 ELL
1-1"X3" SCH.80 PVC NIPPLE
1" SCH.80 PVC FIPxFIP 90 ELL
1"X8" SCH.80 PVC NIPPLE
1-1"X 3" SCH.80 PVC NIPPLE
1" SCH.80 PVC FIPxFIP 90 ELL
PRESSURE MAINLINE SERVICE
TEE - SOLVENT WELD OR
GASKETED FITTING.
QUICK COUPLER VALVE
N.T.S.3"7
VALVE BOX WITH
MATCHING LOCKING
COVER. BRAND COVER
IN 1" MIN. LETTERS FP
TAPE FABRIC TO SIDE
OF VALVE BOX & PIPE
WITH DUCT TAPE
SUBMAIN END
1" (FINISH GRADE PRIOR
TO SOD/SEEDING)
THREADED PVC END
CAP & MALE ADAPTER
4" LAYER OF DRAIN GRAVEL
ABOVE AND BELOW VALVE BOX
EXTENTIONS.
GEOTEXTILE FABRIC
DRIP BLOWOUT
N.T.S.8
NOTES:
1.DIAMETERS OF PVC FITTINGS AND RISER SHALL EQUAL ELECTRIC CONTROL VALVE DIAMETER.
2.VALVE BOXES SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO ADJACENT SIDEWALKS
AND HARD SURFACES WHERE APPLICABLE.
3.PROVIDE 4 FT. MIN. SEPARATION BETWEEN ALL BOXES.
4.SEE SPECIFICATION FOR CONTROL VALVE INSTALLATION
NOTES:
1.INSTALL ASSEMBLY TO REST ON GRAVEL SUMP. CONTAIN
ENTIRE ASSEMBLY WITHIN BOX. VALVE BOX TO BE FLUSH
WITH FINISH GRADE.
RECTANGULAR VALVE BOX. BRAND LID WITH
CONTROLLER & STATION #. REFER TO TECHNICAL
SPECIFICATIONS.
FINISHED GRADE
ELECTRIC CONTROL VALVE
PVC BALL VALVE (FxF)
PROVIDE 29 1/2" CONTINUOUS COILS OF ALL
OF ALL SPARE CONTROL/COMMON WIRING
WITHIN VALVE BOX.
SCH.40 PVC SLIPxMALE 90 ELL
PEA GRAVEL ROCK SUMP - 1 CU. FT.
SCH.80 PVC NIPPLE (LENGTH AS REQUIRED)
SERVICE TEE - SOLVENT WELD
COVER ROCK SUMP WITH SOIL FILTER FABRIC
(FULL LENGTH AND WIDTH OF VALVE BOX)
SCH.80 NIPPLE CUT OFF + GLUED
1" FILTER WITH 100 MICRON
DISC FILTER ELEMENT
RECTANGULAR VALVE BOX -
BRAND LID WITH
CONTROLLER AND
STATION NUMBER #
UNION FIPT X FIPT
1" PVC
PVC BALL VALVE
PVC PRESSURE MAINLINE
CONTROL VALVE
1" PRESSURE REGULATING VALVE
3/4" CRUSHED GRAVEL SUMP - 1 CU. FT.
PVC UNION - 1" (FIPTxFIPT)
ELECTRIC CONTROL VALVE
N.T.S.
SPECIFIED LATERAL PIPING
DEPTH MAINTAIN 8"
VERTICAL CLEARANCE
BETWEEN TOP OF PIPE &
VALVE BOX
9
FINISHED GRADE
PVC SCH 40 ELL
PVC SCH 80 NIPPLE (LENGTH AS REQUIRED)
30" LINEAR LENGTH OF WIRE, COILED
WATERPROOF CONNECTION: SPLICE-1 (1 OF 2)
ID TAG
VALVE BOX WITH COVER
PVC SCH 40 FEMALE ADAPTER
LATERAL PIPE
BRICK (1 OF 4)
3" MINIMUM DEPTH OF 3/4" PEA
GRAVEL
CONTROL ZONE KIT: (INCLUDES 1" VALVE,
BACK FLUSH PRESSURE REGULATING
FILTER, DUCK BILL BOOT).
PVC SCH 80 NIPPLE (2-INCH LENGTH,
HIDDEN) AND PVC SCH 40 ELL
PVC SCH 40 TEE OR ELL
PVC MAINLINE
1" DRIP ZONE KIT
N.T.S.3"10