HomeMy WebLinkAbout032_L3.1_IrrigationNotesAndSchedulesSYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI RAIN BIRD XCZ-100-LC WIDE FLOW DRIP CONTROL KIT, FOR LIGHT COMMERCIAL USES. 1IN. PEB VALVE, WITH 1IN. PRESSURE REGULATING 40PSI BASKET FILTER. 0.3-20 GPM. 10 RAIN BIRD XFCV-06-12 DRIP RING 300 40 AREA TO RECEIVE DRIP EMITTERS RAIN BIRD XB-PC SINGLE OUTLET, PRESSURE COMPENSATING DRIP EMITTERS. FLOW RATES OF 0.5 GPH=BLUE, 1.0 GPH=BLACK, AND 2.0 GPH=RED. COMES WITH A SELF-PIERCING BARB INLET X BARB OUTLET. 4,546 S.F.20 Emitter Notes: 10PC emitters (1 assigned to each 1 GAL plant)20 10PC emitters (1 assigned to each 2 GAL. plant)68 10PC emitters (2 assigned to each 5 GAL plant) 10PC emitters (2 assigned to each 5 GAL. plant)160 SYMBOL MANUFACTURER/MODEL/DESCRIPTION LANDSCAPE PRODUCTS INC. CWV SLIP SOCKET 1/2IN., 3/4IN., 1IN., 1-1/4IN., 1-1/2IN.,2IN. SLIP SOCKET PLASTIC BALL VALVE. QUARTER-TURN SHUTOFF DESIGNED FOR IRRIGATION, SPAS, POOLS AND OTHER GENERAL COLD WATER APPLICATIONS. 125 PSI RATING. SAME SIZE AS MAINLINE. RAIN BIRD PSI-H50X-100 PRESSURE REGULATION: 50 PSI, FLOW RANGE: 0.5 GPM TO 35 GPM, INLET/OUTLET SIZE: 1” FEMALE NPT X 1” FEMALE NPT PRESSURE REQUIRED DOWNSTREAM IS 72.6 PSI ZURN 375 1-1/4" REDUCED PRESSURE PRINCIPLE ASSEMBLY. SIZES 1/2IN.,3/4IN., 1IN., 1-1/4IN., 1-1/2IN., 2IN.. RAIN BIRD ESPLXIVM-LXMMSS 60 STATION, 2-WIRE CONTROLLER W/ SMART VALVE TECHNOLOGY. (1) ESPLXIVM 60-STATION, INDOOR/OUTDOOR, PLASTIC WALL-MOUNT ENCLOSURE. INSTALLED IN LXMMSS STAINLESS STEEL WALL-MOUNTED CABINET. SYSTEM REQUIREMENTS: RAIN BIRD LXIVM-XXX INTEGRATED VALVE MODULES & 2-WIRE DEVICES. USE PAIGE ELECTRIC CABLE P7072D & RAIN BIRD WC20 DRY SPLICES ONLY. GROUND SYSTEM W/ (X) LXIVMSD SURGE DEVICE IN RAIN BIRD ROUND VALVE BOXES. INSTALL PER MANUFACTURERS RECOMMENDATIONS. RAIN BIRD SMRT-Y SOIL MOISTURE SENSOR KIT. 24VAC @ 50/60 HZ. OPERATING TEMPERATURE: -4 DEGREES F TO 158 DEGREES F. SURVIVAL TEMPERATURE: -40 DEGREES F TO 185 DEGREES F. UL, CUL, C-TICK CERTIFICATIONS. RAIN BIRD UFS-150 1-1/2IN. ULTRASONIC FLOW SENSORS, WITH GLASS FILLED NYLON BODY. OPERATING RANGE 0.5 GPM TO . SIZE FOR FLOW NOT ACCORDING TO PIPE SIZE. IRRIGATION LATERAL LINE: POLYETHYLENE PIPE SDR-7 IRRIGATION MAINLINE: POLYETHYLENE PIPE SDR-7 PIPE SLEEVE: PVC SCHEDULE 40 C SM FS LIMIT OF WORK SNOW STORAGE NUMBER MODEL SIZE TYPE GPM HEADS DESIGN PSI PSI PSI @ POC PRECIP 1 RAIN BIRD XCZ-100-LC 1"DRIP RING 0.6 10 40 41.2 0.46 in/h 2 RAIN BIRD XCZ-100-LC 1"AREA FOR DRIP EMITTERS 1.35 20 21.7 0.3 in/h 3 RAIN BIRD XCZ-100-LC 1"DRIP RING 0.96 16 40 41.5 0.46 in/h 4 RAIN BIRD XCZ-100-LC 1"DRIP RING 1.68 28 40 41.8 0.46 in/h 5 RAIN BIRD XCZ-100-LC 1"AREA FOR DRIP EMITTERS 2.85 20 22.4 0.33 in/h 6 RAIN BIRD XCZ-100-LC 1"DRIP RING 0.3 5 40 41.0 0.46 in/h 7 RAIN BIRD XCZ-100-LC 1"DRIP RING 0.96 16 40 41.5 0.46 in/h 8 RAIN BIRD XCZ-100-LC 1"DRIP RING 4.38 73 40 42.9 0.46 in/h 9 RAIN BIRD XCZ-100-LC 1"DRIP RING 3.9 65 40 43.1 0.46 in/h 10 RAIN BIRD XCZ-100-LC 1"DRIP RING 5.16 86 40 44.2 0.46 in/h P.O.C. NUMBER: 01 Water Source Information: FLOW AVAILABLE Point of Connection Size:1" Flow Available 19.62 GPM PRESSURE AVAILABLE Static Pressure at POC:100 PSI Pressure Available:100 PSI DESIGN ANALYSIS Maximum Station Flow:8.76 GPM Flow Available at POC:19.62 GPM Residual Flow Available:10.86 GPM Critical Station:8 Design Pressure:40 PSI Friction Loss:0.15 PSI Fittings Loss:0.01 PSI Elevation Loss:0 PSI Loss through Valve:2.77 PSI Pressure Req. at Critical Station:27.1 PSI Loss for Fittings:0.55 PSI Loss for Main Line:5.54 PSI Loss for POC to Valve Elevation:0 PSI Loss for Backflow:12 PSI Critical Station Pressure at POC:45.1 PSI Pressure Available:100 PSI Residual Pressure Available:54.9 PSI UULC  FILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTIONa sanderson bellecci companyWHEAT DRIVEIRRIGATION NOTES AND SCHEDULESSIMKINS-HALLIN TRACT 3-BNORTH PARK SIMKINS-HALLIN SITE DEVELOPMENTBOZEMAN, MTL3.1 TP21363_01_IR_PROD_T3-B.DWGCS/KA01/31/24SITE PLAN SUBMITTAL06/14/24-----SITE PLAN SUBMITTAL-------21363.01IRRIGATION LEGEND SITE LEGEND IRRIGATION NOTES 1.THIS SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 90 PSI, AT A MAXIMUM DISCHARGE OF 50 GPM AT THE 1.5" POINT-OF-CONNECTION. CONTRACTOR TO VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. 2.THE IRRIGATION SYSTEM POINT-OF-CONNECTION SHALL BE IN MECHANICAL ROOM IN BUILDING AT SOURCE PROVIDED APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION/ANTI SIPHON ASSEMBLY PER CITY & STATE BUILDING CODES. VERIFY EXACT LOCATION OF P.O.C. WITH OWNERS REPRESENTATIVE. 3.CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE. FINAL LOCATION TO BE APPROVED BY OWNERS REPRESENTATIVE. 4.COORDINATE UTILITY LOCATES OF ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 5.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE CONSIDERED IN THE DESIGN PROCESS. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 6.DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: A.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE OF PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE, WIRING, VALVES, ETC. IN LANDSCAPED AREAS AND WITH PROPERTY LINES. B.TREE AND SHRUB LOCATION SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. C.USE ONLY STANDARD TEES AND ELBOW FITTINGS. 7.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: A.TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES AND CONTROLLERS. 8.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. IRRIGATION CONTRACTOR TO COORDINATE WITH SITE CONTRACTOR FOR TIME OF INSTALLATION AND LOCATION OF ANY SLEEVE AND/OR CONDUIT INSTALLATION. 9.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10.INSTALL TWO (2) #14 AWG CONTROL WIRES FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE FOR USE AS SPARE INCASE OF CONTROL WIRE FAILURE. COIL 3 FEET OF WIRE IN VALVE BOX. 11.ALL PLANT MATERIAL NOT LOCATED IN LAWN AREAS SHALL BE DRIP IRRIGATED BY AUTOMATIC CONTROLLED SYSTEM. RAINBIRD EQUIPMENT OR EQUAL. A COMPLETE LIST OF EQUIPMENT, SHOP DRAWING CATALOG CUTS, LAYOUT PERFORMANCE AND MAINTENANCE WARRANTY INFORMATION SHALL BE SUBMITTED TO THE OWNERS REPRESENTATIVE FOR APPROVAL PRIOR TO COMMENCING WORK. SAID INFORMATION SHALL BE COMPILED ALONG WITH AS-BUILT DRAWINGS AND MAINTENANCE INSTRUCTION AND SUBMITTED TO OWNER'S REPRESENTATIVE FOR APPROVAL AT FINAL COMPLETION. CONTRACTOR SHALL DEMONSTRATE COMPLETE OPERATING SYSTEM AND MAINTENANCE TO OWNER'S REPRESENTATIVE AND OWNER'S MAINTENANCE AND OPERATING PERSONNEL. 12.CONTRACTOR SHALL BE REQUIRED TO START UP AND WINTERIZE SYSTEM FOR THE WARRANTY PERIOD, ONE YEAR FROM FINAL COMPLETION, AND MAKE ALL ADJUSTMENTS AND REPAIRS REQUIRED TO INSURE EFFICIENT OPERATION. 13.CONTRACTOR SHALL PROVIDE ALL REQUIRED IRRIGATION WATER CONTROL, FILTRATION PRESSURE REGULATION, WASTE AND DRAINAGE REQUIREMENTS OF A COMPLETE MAINTENANCE SYSTEM. VALVE SCHEDULE CRITICAL ANALYSIS IRRIGATION WATER REQUIREMENTS BASED ON CITY OF BOZEMAN WATER BUDGET CALCULATOR: TOTAL WATER USE = 61,890 GALLONS A YEAR GAL/SF AVERAGE = .4