Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
028 G000 Cover Sheet - TruNorth Office
ABBREVIATIONS MATERIAL LEGEND PROJECT INFORMATION GENERAL NOTES STREET ADDRESS OWNER / DEVELOPER GRAVEL MASONRY METAL CONCRETE EARTH BATT INSULATION RIGID INSULATION FINISH WOOD ACOUSTIC TILE LEGAL DESCRIPTION ROUGH WOOD DESIGN CRITERIA VICINITY MAP CONSULTANTS: Copyright © 2022 Springer Group Architects, P.C. DRAWING LIST OCCUPANCY TYPE: BUILDING HEIGHT: NO. OF STORIES: TOTAL BUILDING AREA (Gross): THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE FIELD MEASUREMENTS PRIOR TO ORDERING MATERIALS & PRE- FABRICATING ITEMS. ANY NECESSARY ADJUSTMENTS IN FIELD MEASUREMENTS AND/OR BETWEEN FIELD MEASUREMENTS AND DRAWINGS SHALL BE MADE IN ACCORDANCE WITH THE DECISION OF THE ARCHITECT AND OWNER. CONTRACTOR SHALL PROVIDE BACKING/BLOCKING AS REQUIRED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC. CONTRACTOR IS TO SUPPLY AND INSTALL A 4'-0" x 8'-0" BUILDING CONSTRUCTION SIGN WHICH STATES THE FOLLOWING: GENERAL CONTRACTOR OWNER/DEVELOPER ADDRESS & PHONE ADDRESS & PHONE ARCHITECT DEVELOPMENT NAME ADDRESS & PHONE & ADDRESS ALL PARTITION DIMENSIONS ARE TO FACE OF FRAMING OR TO CENTERLINE OF PARTITIONS, STRUCTURAL COLUMNS, AND BEAMS U.N.O. APPROVED FLASHING TO BE INSTALLED AT ALL CHIMNEYS, WALL-TO-ROOF INTERSECTIONS, AROUND ALL ROOF PENETRATIONS, AND ABOVE ALL EXTERIOR DOOR AND WINDOW OPENINGS. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF AND BETWEEN WALLS AND PANELS, OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOOR AND ROOFS, AND ALL OTHER SUCH OPENINGS INTO THE BUILDING ENVELOPE, INCLUDING ACCESS PANELS INTO UNHEATED SPACES SHALL BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. ALL EXTERIOR DOORS SHALL BE DESIGNED TO LIMIT AIR LEAKAGE AROUND THEIR PERIMETER WHEN IN THE CLOSED POSITION. PROVIDE GYPSUM WALLBOARD OF TYPE AND THICKNESS INDICATED ON DRAWINGS. GYPSUM BOARD WORK AND MATERIALS SHALL MEET ALL REQUIREMENTS OF ANSI NO. A97-1 FOR THE "APPLICATION AND FINISHING OF WALLBOARD". JOINT COMPOUND SYSTEM MIXED, APPLIED AND FINISHED IN COMPLIANCE WITH MANUFACTURERS PRINTED DIRECTIONS. JOINTS TO BE INVISIBLE AFTER FINISHED, INCLUDING ALL METAL CORNER BEADS AND TRIM. THE FOLLOWING ARE BUILDING CODES THAT HAVE BEEN ADOPTED BY THE AUTHORITIES HAVING JURISDICTION (AHJ): - INTERNATIONAL BUILDING CODE, 2021 EDITION (ARM Rule 24.301.146) - ICC A117.1 - ACCESSIBILITY, 2017 EDITION (ARM Subchapter 24.301.9) - INTERNATIONAL ENERGY CONSERVATION CODE, 2021 EDITION (ARM Rule 24.301.161) - INTERNATIONAL EXISTING BUILDING CODE, 2021 EDITION (ARM Rule 24.301.171) - INTERNATIONAL MECHANICAL CODE, 2021 EDITION (ARM Rule 24.301.172) - UNIFORM PLUMBING CODE, 2021 EDITION (ARM Rule 24.301.301) - NATIONAL ELECTRICAL CODE, 2021 EDITION (ARM Rule 24.301.401) - INTERNATIONAL FUEL GAS CODE, 2021 EDITION (ARM Rule 24.301.173) - INTERNATIONAL SWIMMING POOL AND SPA CODE, 2021 EDITION (ARM Rule 24.301.175) THE BUILDER ACKNOWLEDGES THESE CODES ARE APPLICABLE TO ALL SHEETS, NOTES AND TABLES IN THESE PLANS AND ASSURES THE LOCAL JURISDICTION HE OR SHE WILL COMPLY WITH ALL CURRENT AND LOCAL CODES. ADOPTED BUILDING CODES THESE PLANS HAVE BEEN DESIGNED IN COMPLIANCE WITH THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. GENERAL CONTRACTOR MUST NOTE THAT ADDITIONAL ACCESSIBILITY REQUIREMENTS MAY ALSO BE REQUIRED BY STATE OR LOCAL CODES. THE TERM "ACCESSIBLE" WILL BE USED THROUGHOUT THESE PLANS TO REFER TO THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN WHICH ARE MANDATED FOR PLACES OF PUBLIC ACCOMMODATION BY TITLE III REGULATIONS OF THE ADA AT 28 CFR PART 36, SUBPART D, AND MUST FOLLOW THE 2004 ADAAG AT 36 CFT PART 1191, APPENDICES B AND D. OWNER MUST ALSO ENSURE THAT THE FACILITY IS CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE ADA STANDARDS. PROJECT ACCESSIBILITY NOTES @ - AT # - POUND(S) OR NUMBER +/- - PLUS MINUS AFF - ABOVE FINISH FLOOR AC - ACOUSTICAL ACT - ACOUSTICAL CEILING TILE ADJ - ADJACENT A/C - AIR CONDITIONING ALT - ALTERNATIVE ALUM. - ALUMINUM ALT - ALTERNATIVE ALUM. - ALUMINUM A.B. - ANCHOR BOLT APPD - APPROVED APPROX. - APPROXIMATE ARCH - ARCHITECT(URAL) BSMT - BASEMENT BM. - BEAM BRG - BEARING BLKG - BLOCKING BD - BOARD BOT - BOTTOM BLDG - BUILDING B.U.R. - BUILT UP ROOFING CAB - CABINET CLG - CEILING C\C OR C.C. - CENTER TO CENTER CL OR C.L. - CENTERLINE CT - CERAMIC TILE CLR - CLEAR C.W. - COLD WATER COL - COLUMN CF OR C.F. - COMMUNICATION FEATURES COMP. - COMPACT(ED) CONC - CONCRETE CMU - CONCRETE MASONRY UNIT CONST - CONSTRUCTION CJ OR C.J. - CONTROL JOINT CONT. - CONTINUOUS CORR. - CORRIDOR DTL. - DETAIL DEPT. - DEPARTMENT DIA. - DIAMETER DIV. - DIVISION DBL. - DOUBLE DN - DOWN DS - DOWNSPOUT DWG - DRAWING D.F. - DRINKING FOUNTAIN EA - EACH E.W. - EACH WAY EF - EACH FACE ELEC - ELECTRIC(AL) EWC OR E.W.C. - ELECTRIC WATER COOLER EL. - ELEVATION ELEV. - ELEVATOR EMERG. - EMERGENCY ENCL. - ENCLOSURE ENG. - ENGINEER EQ - EQUAL EQUIP. - EQUIPMENT EXG - EXISTING EXP - EXPOSED EJ OR EJ. OR E.J. - EXPANSION JOINT EXT - EXTERIOR F.R.P. - FIBER REINFORCED PLASTIC FF - FINISH FLOOR FIN - FINISH(ED) FBO - FINISH BY OTHERS F.A. - FIRE ALARM FC - FIRE CODE F.E. - FIRE EXTINQUISHER F.E.C. - FIRE EXTINQUISHER CABINET FP - FIREPROOF F.R. - FIRE RESISTANT FLR - FLOOR FD OR F.D. - FLOOR DRAIN FLUOR. - FLUORESCENT FT - FOOT (FEET) FTG - FOOTING FDN. - FOUNDATION FRM. - FRAME GA - GAGE, GAUGE GALV. - GALVANIZED GC - GENERAL CONTRACTOR GL. - GLASS/GLAZING GYP. BD.- - GYPSUM BOARD HDWR. - HARDWARE HVAC - HEATING/VENT./AIR COND. HADG - HILTON ACCESSIBILITY DESIGN HC - HOLLOW CORE HM - HOLOW METAL HORIZ. - HORIZONTAL H.B. - HOSE BIB H.W. - HOT WATER HR - HOUR IN. - INCH(ES) INCL - INCLUDE(ING) INSUL - INSULATE(ION) INT - INTERIOR INV. - INVERT JAN. - JANITOR(IAL) JT - JOINT KIT. - KITCHEN K.O. - KNOCKOUT LAM - LAMINATE LAV. - LAVATORY LT. WT. - LIGHT WEIGHT LL - LIVE LOAD LB. OR LBS. - POUND(S) MFR - MANUFACTURER M.H. - MAN HOLE MAS - MASONRY M.O. - MASONRY OPENING MAX - MAXIMUM MECH - MECHANICAL MED. - MEDIUM MTL - METAL MM - MILLIMETER MIN - MINIMUM MISC. - MISCELLANEOUS MR OR M.R. - MOISTURE RESISTANT MTD. - MOUNTED NAT - NATURAL NR - NOISE REDUCTION NOM - NOMINAL NO - NUMBER NIC - NOT IN CONTRACT NTS - NOT TO SCALE OC - ON CENTER OPG - OPENING OD - OUTSIDE DIAMETER OH - OVERHANG PNL - PANEL PBD - PARTICLE BOARD PVMT - PAVEMENT PLF - PER LINEAR FOOT PL - PLATE PLWD - PLYWOOD PVC - POLYVINYL CHLORIDE PSF - POUND PER SQ. FOOT PSI - POUND PER SQ. INCH PLBG. - PLUMBING P.T. - PRESSURE TREATED RAD - RADIUS REF - REFERENCE REINF - REINFORCE(D) R.A. - RETURN AIR REQ'D - REQUIRED R - RISER RFG - ROOFING RO OR R.O. - ROUGH OPENING RD. OR R.D. - ROOF DRAIN SHT - SHEET SIM - SIMILAR SC - SOLID CORE SPK - SPEAKER SPEC - SPECIFICATION SQ - SQUARE STR - STRUCTURE(AL) SS - STAINLESS STEEL ST. - STREET STD. - STANDARD STL. - STEEL STOR. - STORAGE SUSP. - SUSPENDED SYS - SYSTEM TEL. - TELEPHONE TV OR T.V. - TELEVISION TEMP. - TEMPORARY OR TEMPERED THK - THICK(NESS) T&G - TONGUE & GROOVE T&B - TOP & BOTTOM T - TREAD TS OR T.S. - TUBE STEEL TYP. - TYPICAL U.N.O. - UNLESS NOTED OTHERWISE VERT. - VERTICAL VIF OR V.I.F. - VERIFY IN FIELD VCT - VINYL COMPOSITION TILE VB - VINYL BASE WSCT. - WAINSCOT WC - WATER CLOSET WP - WATERPROOF(ING) W.V. - WATER VALVE WT. - WEIGHT WWF OR W.W.F. - WELDED WIRE FABRIC WWM OR W.W.M. - WELDED WIRE MESH W.F. - WIDE FLANGE W - WIDE, WIDTH W/ - WITH W/O - WITHOUT WD - WOOD WIN - WINDOW CONSTRUCTION TYPE: SPRINKLED: FROST DEPTH: BASIC GROUND SNOW LOAD: DESIGN WIND SPEED: SEISMIC DESIGN CATEGORY: CURRENT ZONING: MIXED USE/OCCUPANCY: TOTAL BUILDING AREA (Code):9/14/2023 8:10:19 AMTruNorth Center TruNorth Construction Offices 1340 E. Main St. Bozeman Montana 21-018TruNorth Center TruNorth Construction OfficesOwner 1340 E. Main St. Bozeman Montana 9-14-2023 G000 COVER SHEET 11626 11626 GENERAL G000 COVER SHEET G001 PROJECT & CODE INFORMATION G002 CODE INFORMATION & ASSEMBLIES ARCHITECTURAL A000 INSTALLATION STANDARDS A100 SITE PLAN A101 SITE DETAILS A102 SITE DETAILS A200 FIRST LEVEL FLOOR PLAN A201 SECOND LEVEL FLOOR PLAN A202 ROOF PLAN A250 FIRST LEVEL REFLECTED CEILING PLAN A251 SECOND LEVEL REFLECTED CEILING PLAN A300 EXTERIOR ELEVATIONS A301 EXTERIOR ELEVATIONS A302 EXTERIOR PERSPECTIVES A400 BUILDING SECTIONS A401 BUILDING SECTIONS A402 BUILDING SECTIONS A450 WALL SECTIONS A451 WALL SECTIONS A500 ENLARGED FLOOR PLANS A501 ENLARGED FLOOR PLANS A550 INTERIOR ELEVATIONS A551 INTERIOR ELEVATIONS A600 EXTERIOR DETAILS A601 EXTERIOR DETAILS A602 EXTERIOR DETAILS A650 INTERIOR DETAILS A700 DOOR SCHEDULE & DETAILS A701 STOREFRONT SYSTEMS A702 STOREFRONT SYSTEMS A703 STOREFRONT SYSTEM DETAILS A704 WINDOW SCHEDULE & DETAILS A705 ROOM FINISH SCHEDULE STRUCTURAL S001 STRUCTURAL COVER SHEET S002 GENERAL NOTES S003 SCHEDULES S100 FOUNDATION PLAN S200 FIRST FLOOR FRAMING PLAN S201 SECOND FLOOR FRAMING PLAN S202 LOWER ROOF FRAMING PLAN S203 UPPER ROOF FRAMING PLAN S301 FRAMING ELEVATIONS S401 FOUNDATION DETAILS S402 FOUNDATION DETAILS S501 FRAMING DETAILS S502 FRAMING DETAILS S601 ENLARGED PLANS S701 TYPICAL DETAILS S702 TYPICAL DETAILS PROJECT LOCATION