Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
014 G000 Cover Sheet - Alza Building
ABBREVIATIONSMATERIAL LEGENDPROJECT INFORMATIONGENERAL NOTESSTREET ADDRESSOWNER / DEVELOPERGRAVELMASONRYMETALCONCRETEEARTHBATT INSULATIONRIGID INSULATIONFINISH WOODACOUSTIC TILELEGAL DESCRIPTIONROUGH WOODDESIGN CRITERIAVICINITY MAPCONSULTANTS:Copyright © 2023 Springer Group Architects, P.C.DRAWING LISTOCCUPANCY TYPE:BUILDING HEIGHT:NO. OF STORIES:TOTAL BUILDING AREA (Gross):THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE FIELD MEASUREMENTS PRIOR TO ORDERING MATERIALS & PRE-FABRICATING ITEMS. ANY NECESSARY ADJUSTMENTS IN FIELD MEASUREMENTS AND/OR BETWEEN FIELD MEASUREMENTS AND DRAWINGS SHALL BE MADE IN ACCORDANCE WITH THE DECISION OF THE ARCHITECT AND OWNER.CONTRACTOR SHALL PROVIDE BACKING/BLOCKING AS REQUIRED FOR ALL WALL MOUNTED EQUIPMENT, FURNISHINGS, ETC.CONTRACTOR IS TO SUPPLY AND INSTALL A 4'-0" x 8'-0" BUILDING CONSTRUCTION SIGN WHICH STATES THE FOLLOWING:GENERAL CONTRACTOR OWNER/DEVELOPERADDRESS & PHONE ADDRESS & PHONEARCHITECT DEVELOPMENT NAMEADDRESS & PHONE & ADDRESSALL PARTITION DIMENSIONS ARE TO FACE OF FRAMING OR TO CENTERLINE OF PARTITIONS, STRUCTURAL COLUMNS, AND BEAMS U.N.O.APPROVED FLASHING TO BE INSTALLED AT ALL CHIMNEYS, WALL-TO-ROOF INTERSECTIONS, AROUND ALL ROOF PENETRATIONS, AND ABOVE ALL EXTERIOR DOOR AND WINDOW OPENINGS.EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AND ROOF AND BETWEEN WALLS AND PANELS, OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOOR AND ROOFS, AND ALL OTHER SUCH OPENINGS INTO THE BUILDING ENVELOPE, INCLUDING ACCESS PANELS INTO UNHEATED SPACES SHALL BE SEALED, CAULKED, GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. ALL EXTERIOR DOORS SHALL BE DESIGNED TO LIMIT AIR LEAKAGE AROUND THEIR PERIMETER WHEN IN THE CLOSED POSITION.PROVIDE GYPSUM WALLBOARD OF TYPE AND THICKNESS INDICATED ON DRAWINGS. GYPSUM BOARD WORK AND MATERIALS SHALL MEET ALL REQUIREMENTS OF ANSI NO. A97-1 FOR THE "APPLICATION AND FINISHING OF WALLBOARD". JOINT COMPOUND SYSTEM MIXED, APPLIED AND FINISHED IN COMPLIANCE WITH MANUFACTURERS PRINTED DIRECTIONS. JOINTS TO BE INVISIBLE AFTER FINISHED, INCLUDING ALL METAL CORNER BEADS AND TRIM.THE FOLLOWING ARE BUILDING CODES THAT HAVE BEEN ADOPTED BY THE AUTHORITIES HAVING JURISDICTION (AHJ):- INTERNATIONAL BUILDING CODE, 2021 EDITION(ARM Rule 24.301.146)- ICC A117.1 - ACCESSIBILITY, 2017 EDITION(ARM Subchapter 24.301.9)- INTERNATIONAL ENERGY CONSERVATION CODE, 2021 EDITION(ARM Rule 24.301.161)- INTERNATIONAL EXISTING BUILDING CODE, 2021 EDITION(ARM Rule 24.301.171)- INTERNATIONAL MECHANICAL CODE, 2021 EDITION(ARM Rule 24.301.172)- UNIFORM PLUMBING CODE, 2021 EDITION(ARM Rule 24.301.301)- NATIONAL ELECTRICAL CODE, 2021 EDITION(ARM Rule 24.301.401)- INTERNATIONAL FUEL GAS CODE, 2021 EDITION(ARM Rule 24.301.173)- INTERNATIONAL SWIMMING POOL AND SPA CODE, 2021 EDITION(ARM Rule 24.301.175)THE BUILDER ACKNOWLEDGES THESE CODES ARE APPLICABLE TO ALL SHEETS, NOTES AND TABLES IN THESE PLANSAND ASSURES THE LOCAL JURISDICTION HE OR SHE WILL COMPLY WITH ALL CURRENT AND LOCAL CODES.ADOPTED BUILDING CODESTHESE PLANS HAVE BEEN DESIGNED IN COMPLIANCE WITH THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. GENERAL CONTRACTOR MUST NOTE THAT ADDITIONAL ACCESSIBILITY REQUIREMENTS MAY ALSO BE REQUIRED BY STATE OR LOCAL CODES. THE TERM "ACCESSIBLE" WILL BE USED THROUGHOUT THESE PLANS TO REFER TO THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN WHICH ARE MANDATED FOR PLACES OF PUBLIC ACCOMMODATION BY TITLE III REGULATIONS OF THE ADA AT 28 CFR PART 36, SUBPART D, AND MUST FOLLOW THE 2004 ADAAG AT 36 CFT PART 1191, APPENDICES B AND D. OWNER MUST ALSO ENSURE THAT THE FACILITY IS CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE ADA STANDARDS.PROJECT ACCESSIBILITY NOTES@-AT# - POUND(S) OR NUMBER+/- - PLUS MINUSAFF - ABOVE FINISH FLOORAC - ACOUSTICAL ACT - ACOUSTICAL CEILING TILEADJ - ADJACENTA/C - AIR CONDITIONINGALT - ALTERNATIVEALUM. - ALUMINUMALT - ALTERNATIVEALUM. - ALUMINUMA.B. - ANCHOR BOLTAPPD - APPROVEDAPPROX. - APPROXIMATEARCH - ARCHITECT(URAL)BSMT - BASEMENTBM. - BEAMBRG - BEARINGBLKG - BLOCKINGBD - BOARDBOT - BOTTOMBLDG - BUILDINGB.U.R. - BUILT UP ROOFINGCAB - CABINETCLG - CEILINGC\C OR C.C. - CENTER TO CENTERCL OR C.L. - CENTERLINECT - CERAMIC TILECLR - CLEARC.W. - COLD WATERCOL - COLUMNCF OR C.F. - COMMUNICATION FEATURESCOMP. - COMPACT(ED)CONC - CONCRETECMU - CONCRETE MASONRY UNITCONST - CONSTRUCTIONCJ OR C.J. - CONTROL JOINTCONT. - CONTINUOUSCORR. - CORRIDORDTL. - DETAILDEPT. - DEPARTMENTDIA. - DIAMETERDIV. - DIVISIONDBL. - DOUBLEDN - DOWNDS - DOWNSPOUTDWG - DRAWINGD.F. - DRINKING FOUNTAINEA - EACHE.W. - EACH WAYEF - EACH FACEELEC - ELECTRIC(AL)EWC OR E.W.C. - ELECTRIC WATER COOLEREL. - ELEVATIONELEV. - ELEVATOREMERG. - EMERGENCYENCL. - ENCLOSUREENG. - ENGINEEREQ - EQUALEQUIP. - EQUIPMENTEXG - EXISTINGEXP - EXPOSEDEJ OR EJ. OR E.J. - EXPANSION JOINTEXT - EXTERIORF.R.P. - FIBER REINFORCED PLASTICFF - FINISH FLOORFIN - FINISH(ED)FBO - FINISH BY OTHERSF.A. - FIRE ALARMFC - FIRE CODEF.E. - FIRE EXTINQUISHERF.E.C. - FIRE EXTINQUISHER CABINETFP - FIREPROOFF.R. - FIRE RESISTANTFLR - FLOORFD OR F.D. - FLOOR DRAINFLUOR. - FLUORESCENTFT - FOOT (FEET)FTG - FOOTING FDN. - FOUNDATIONFRM. - FRAMEGA - GAGE, GAUGEGALV. - GALVANIZEDGC - GENERAL CONTRACTORGL. - GLASS/GLAZINGGYP. BD.- - GYPSUM BOARD HDWR. - HARDWAREHVAC - HEATING/VENT./AIR COND.HADG - HILTON ACCESSIBILITY DESIGNHC - HOLLOW COREHM - HOLOW METALHORIZ. - HORIZONTALH.B. - HOSE BIBH.W. - HOT WATERHR - HOURIN. - INCH(ES)INCL - INCLUDE(ING)INSUL - INSULATE(ION)INT - INTERIORINV. - INVERTJAN. - JANITOR(IAL)JT - JOINTKIT. - KITCHENK.O. - KNOCKOUTLAM - LAMINATELAV. - LAVATORYLT. WT. - LIGHT WEIGHTLL - LIVE LOADLB. OR LBS. - POUND(S)MFR - MANUFACTURERM.H. - MAN HOLEMAS - MASONRYM.O. - MASONRY OPENINGMAX - MAXIMUMMECH - MECHANICALMED. - MEDIUMMTL - METALMM - MILLIMETERMIN - MINIMUMMISC. - MISCELLANEOUSMR OR M.R. - MOISTURE RESISTANTMTD. - MOUNTEDNAT - NATURALNR - NOISE REDUCTIONNOM - NOMINALNO - NUMBERNIC - NOT IN CONTRACTNTS - NOT TO SCALEOC - ON CENTEROPG - OPENINGOD - OUTSIDE DIAMETEROH - OVERHANGPNL - PANELPBD - PARTICLE BOARDPVMT - PAVEMENTPLF - PER LINEAR FOOTPL - PLATEPLWD - PLYWOODPVC - POLYVINYL CHLORIDEPSF - POUND PER SQ. FOOTPSI - POUND PER SQ. INCHPLBG. - PLUMBINGP.T. - PRESSURE TREATEDRAD - RADIUSREF - REFERENCEREINF - REINFORCE(D)R.A. - RETURN AIRREQ'D - REQUIREDR-RISERRFG - ROOFINGRO OR R.O. - ROUGH OPENINGRD. OR R.D. - ROOF DRAINSHT - SHEETSIM - SIMILARSC - SOLID CORESPK - SPEAKERSPEC - SPECIFICATIONSQ - SQUARESTR - STRUCTURE(AL)SS - STAINLESS STEELST. - STREETSTD. - STANDARDSTL. - STEELSTOR. - STORAGESUSP. - SUSPENDEDSYS - SYSTEMTEL. - TELEPHONETV OR T.V. - TELEVISIONTEMP. - TEMPORARY OR TEMPEREDTHK - THICK(NESS)T&G - TONGUE & GROOVET&B - TOP & BOTTOMT-TREADTS OR T.S. - TUBE STEELTYP. - TYPICALU.N.O. - UNLESS NOTED OTHERWISEVERT. - VERTICALVIF OR V.I.F. - VERIFY IN FIELDVCT - VINYL COMPOSITION TILEVB - VINYL BASEWSCT. - WAINSCOTWC - WATER CLOSETWP - WATERPROOF(ING)W.V. - WATER VALVEWT. - WEIGHTWWF OR W.W.F. - WELDED WIRE FABRICWWM OR W.W.M. - WELDED WIRE MESHW.F. - WIDE FLANGEW - WIDE, WIDTHW/ - WITHW/O - WITHOUTWD - WOODWIN - WINDOWCONSTRUCTION TYPE:SPRINKLED:FROST DEPTH:BASIC GROUND SNOW LOAD:DESIGN WIND SPEED:SEISMIC DESIGN CATEGORY:CURRENT ZONING:MIXED USE/OCCUPANCY:TOTAL BUILDING AREA (Code):9/29/2023 9:44:56 AMTruNorth CenterALZA Coffee & Doughnuts1342 E. Main Street Bozeman, MT 5971521-018TruNorth Center ALZA Coffee & DoughnutsTRUNORTH PROPERTIES LLC18411 FRONTAGE RDBELGRADE, MT 59714-93981342 E. Main Street Bozeman, MT597159-29-2023G000COVER SHEETA-228'-6"2 STORIES + BASEMENT5423 SQ. FT.ELKS CLUB PROP REARR, S08, T02 S, R06 E,BLOCK 1, Lot 1, ACRES 1.243, PLAT H-29-EV-BYES, PER NFPA 1348 INCHES4190 MPH, EXPOSURE 'C''D'B-2NON-SEPARATED5423 SQ. FT.GENERALG000 COVER SHEETG001 PROJECT & CODE INFORMATIONARCHITECTURALA000 INSTALLATION STANDARDSA100 SITE PLANA200 BASEMENT LEVEL FLOOR PLANA201 FIRST LEVEL FLOOR PLANA202 SECOND LEVEL FLOOR PLANA203 ROOF PLANA250 BASEMENT LEVEL REFLECTED CEILING PLANA251 FIRST LEVEL REFLECTED CEILING PLANA252 SECOND LEVEL REFLECTED CEILING PLANA300 EXTERIOR ELEVATIONSA301 EXTERIOR ELEVATIONSA302 EXTERIOR PERSPECTIVESA400 BUILDING SECTIONSA401 BUILDING SECTIONSA402 BUILDING SECTIONSA403 BUILDING SECTIONSA404 BUILDING SECTIONSA450 WALL SECTIONSA451 WALL SECTIONSA452 WALL SECTIONSA453 WALL SECTIONSA550 INTERIOR ELEVATIONSA551 INTERIOR ELEVATIONSA600 EXTERIOR DETAILSA601 EXTERIOR DETAILSA602 EXTERIOR DETAILSA650 INTERIOR DETAILSA651 INTERIOR DETAILSA700 DOOR SCHEDULE & DETAILSA701 STOREFRONT SYSTEMSA702 STOREFRONT DETAILSA703 WINDOW SCHEDULE & DETAILSA704 ROOM FINISH SCHEDULESTRUCTURALS001 STRUCTURAL COVER SHEETS002 GENERAL NOTESS003 SCHEDULESS100 TYPICAL DETAILSS101 TYPICAL DETAILSS200 FOUNDATION PLANS201 FIRST FLOOR FRAMING PLANS202 SECOND FLOOR FRAMING PLANS203 ROOF FRAMING PLANS300 MOMENT FRAME ELEVATIONS & DETAILSS400 CONCRETE DETAILSS500 FRAMING DETAILSS501 FRAMING DETAILS5,117 SQ. FT.PROJECT LOCATION