Loading...
HomeMy WebLinkAbout046.3 - L304 IRRIGATION DETAILSISOLATION VALVE DETAIL NTS4L3041.FINISH GRADE2.VALVE BOX ASSPECIFIED3.GATE VALVE ASSPECIFIED. LINE SIZE.4.SCH 80 PVC UNION(1 OF 2)5.MAIN LINE PIPE6.6" OF WASHED 34"AGGREGATE BASE7.BRICK SUPPORTS (1OF 4)1NOTES:1.VALVE TO BE SUPPORTED BY GRAVEL, PROVIDE BLOCK SHIM ASREQUIRED234567INSTALLATIONN TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.C10'8'10'TOPVIEWGROUND RODCONTROLLERCONCRETE PAD12"30"SIDEVIEWPLASTIC SWEEP ELL(1 ½" OR LARGER)6 AWG SOLID BARECOPPER WIRESGROUNDING DETAILS 5L304COPPER GROUND PLATECADWELD CONNECTIONCOPPERGROUND PLATEGROUND RODEARTH CONTACT MATERIAL6 AWG SOLID BARECOPPER WIRESMOUNTING WALL3612INSIDE FRONT COVER4573INSIDE CONTROLLER CHASSIS1L304MODULAR HYBRID CONTROLLERESP-ME3 NTS1.MODULAR HYBRID CONTROLLER, RAINBIRD ESP-ME3 INSIDE WALL MOUNT2.1-INCH PVC SCH 40 CONDUIT &FITTINGS3.WIRES TO REMOTE CONTROL VALVES4.STANDARD MODULE FOR 4-STATIONCONTROLLERS5.OPTIONAL MODULES FOR22-STATION CONTROLLER6.STANDARD 120 V PLUG7.120 VAC, 60 HZ INTERNALTRANSFORMER1234596101178961226L304IN VALVE BOX1" CONTROL ZONE KIT NTS1.FINISH GRADE2.STANDARD VALVE BOX W/COVER: RAIN BIRD VB-STD3.WATERPROOF CONNECTION:RAIN BIRD DB SERIES4.VALVE ID TAG5.30" LINEAR LENGTH OF WIRE,COILED6.PRESSURE REGULATINGFILTER: RAIN BIRD PRF-100RBY7.PVC SCH 40 FEMALEADAPTOR8.LATERAL PIPE9.REMOTE CONTROL VALVE10.PVC SCH 40 TEE OR ELL TOMANIFOLD11.3" MINIMUM DEPTH OF 34"WASHED GRAVEL12.MANIFOLD PIPE & FITTINGS7L304WITH MPR NOZZLE1800 SERIES POP-UP SPRINKLER NTS1.FINISH GRADE/TOP OF MULCH2.POP-UP SPRAY SPRINKLER. RAIN BIRD1806/1812-SAMW/ RAIN BIRD MPR NOZZLES3.1/2 INCH MALE NPT X .490 INCHBARB ELBOW: RAIN BIRD MODEL SBE-0504.PPE LATERAL PIPE5.SWING PIPE, 12 INCH LENGTH:RAIN BIRD MODEL SP-1006.PVC SCH 40 TEE OR ELLOUTDOOR WALL1234VT = VALVE TESTVT MVCOM56789101112AUX24 VAC GND SEN WR2WIRELESS SENSORWIRING DETAILSEE WIRING DETAILNOTES:1. FOR BEST PERFORMANCE, THE CONTROLLER INTERFACESHOULD BE INSTALLED AT LEAST FIVE FEET ABOVE THEGROUND.2. IT IS RECOMMENDED THAT THE CONTROLLER INTERFACEBE INSTALLED AWAY FROM SOURCES OF ELECTRICALINTERFERENCE (SUCH AS TRANSFORMERS,GENERATORS, PUMPS, FANS, ELECTRICAL METERBOXES) AND METAL OBJECTS TO MAXIMIZECOMMUNICATION RANGE.1235674COM 24 VAC GND SEN COM2L304WR2 SERIES CONTROLLER INTERFACEWIRELESS RAIN SENSOR (OUTDOOR) NTS1.RAIN BIRD CONTROLLER:RAIN BIRD ESP-4MOUTDOOR WALL MOUNT2.1-INCH PVC SCH 40 CONDUITAND FITTINGS FOR VALVE WIRES3.RAIN BIRD WR2 WIRELESS SENSORCONTROLLER INTERFACE4.CABLE HARNESS FOR CONTOLLERINTERFACE (30" MAX.)5.GROUND WIRE TO GROUNDING GRID6.JUNCTION BOX7.1/2-INCH PVC SCH 40 CONDUITTO POWER SUPPLY1047897611543213L304QUICK COUPLER NTS1.FINISH GRADE/ TOP OFMULCH2.QUICK-COUPLING VALVE3.VALVE BOX WITH COVER4.PVC SCH 80 NIPPLE(LENGTH AS REQUIRED)5.3" MINIMUM DEPTH OF 34"WASHED GRAVEL6.BRICK (1 OF 2)7.PVC SCH 40 STREET ELL8.PVC SCH 40 TEE OR ELL9.PVC MAIN LINE PIPE10.PVC SCH 40 ELL11.2" X 2" REDWOOD STAKEWITH STAINLESS STEELGEAR CLAMPS OREQUIVALENT SUPPORTSYSTEMNOTES:1.INSTALLATIONN TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.2.FURNISH FITTINGS AND PIPING NOMINALLY SIZED IDENTICAL TO NOMINAL QUICK COUPLINGVALVE INLET SIZE.8L304AND TEE MOUNTED FLOW SENSORMASTER VALVE (NORMALLY CLOSED) NTS1.RAIN BIRD MASTERVALVE(S)2.36-INCH LENGTH OFCOILED WIRE TO SATELLITECONTROLLER MASTERVALVE CIRCUT3.3-INCH MINIMUM DEPTHOF 3/4-INCH WASHEDGRAVEL4.BRICK (1 OF 4)5.VALVE BOX WITH COVER -12-INCH SIZE6.FINISH GRADE7.RAIN BIRD FS SERIES150-400P/FS-100A FLOWSENSOR(S)8.36-INCH LENGTH OFCOILED PE-CABLE TOFLOW SENSINGEQUIPMENT ATCCU/SATELLITECONTROLLER ASSEMBLY9.SEE FLOW SENSORWIRING DETAIL FORWIRING DIAGRAM10.CONCENTRIC REDUCER9L304THRUST BLOCK NTSNOTES:1.SIZE THRUST BLOCKS SHALL BE SPECIFIED ASSHOW IN THE TABLE.2.CONTROL WIRES SHALL NOT BE ENCASED INCONCRETE.3.ALL FITTINGS SHALL BE WRAPPED WITHPOLYETHYLENE TO PREVENT CONCRETE FROMADHERING TO PIPE, FITTINGS OR BOLTS.4.JOINTS AND BOLTS SHALL BE ACCESSIBLE FORREPAIRS.5.THRUST BLOCKS SHALL BE A MINIMUM OF 6"THICK.6.ONE 80 LBS. SACK OF CONCRETE SHALL COVER.6 FT.³PIPE SIZETEE AND PLUG90° BEND45° BEND1-1/2"2"2-1/2"3"4"6"8"10"14.93 FEET ²9.08 FEET ²5.25 FEET ²2.43 FEET ²1.48 FEET ²1.0 FEET ²0.69 FEET ²0.45 FEET ²0.63 FEET ²0.97 FEET ²1.41 FEET ²2.10 FEET ²3.45 FEET ²7.41 FEET ²12.83 FEET ²21.07 FEET ²11.44 FEET ²6.96 FEET ²4.02 FEET ²1.87 FEET ²1.14 FEET ²0.77 FEET ²0.53 FEET ²0.34 FEET ²1.BEARING SURFACE2.EXISTING OR MODIFIEDSOIL (SEE SPECIFICATIONFOR SOIL MODIFICATION)3.FLOW DIRECTION211312NOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE AND LATERAL LINE PIPE SIZE AND TYPE.2.DIRECT BURIAL CONTROL WIRES SHALL BE INSTALLED IN SCH. 40 PVC ELECTRICAL CONDUIT IFREQUIRED.3.2-WIRE IRRIGATION WIRE SHALL BE INSTALLED IN SCH. 40 PVC ELECTRICAL CONDUIT.4.DETECTABLE LOCATOR TAPE SHALL BE LOCATED SIX INCHES (6") ABOVE THE ENTIRE MAINLINE RUN.345610L304IRRIGATION TRENCHING NTS1.FINISHED GRADE2.PAVEMENT3.NON-PRESSURIZEDLINE (LATERAL LINE)4.DETECTABLELOCATOR TAPE5.PRESSURIZED LINE(MAINLINE)6.DIRECT BURIAL LOWVOLTAGE CONTROLWIRES24" MIN.6" 1'-0" IN PLANTING AREA 1'-6" IN PLANTING AREA3'-0" UNDERNEATH PAVEMENT NOTES:1.ALL ASSEMBLY PARTS (THREADED NIPPLES, FITTINGS, ETC.) SHALL BEGALVANIZED OR BRASS PER LOCAL CODES AND REQUIREMENTS.2.GALVANIZED NIPPLE SHALL EXTEND 12" PAST THE EDGE OF THE CONCRETEFOOTING.3.SCH. 80 PVC MALE ADAPTER SHALL BE USED IN CONNECTION FROMGALVANIZE TO THE MAINLINE.4.BACKFLOW PREVENTION DEVICE SHALL BE LOCATED AS CLOSE ASPOSSIBLE TO THE LANDSCAPE METER.5.BACKFLOW PREVENTION DEVICE SHALL BE LOCATED IN PLANTING AREAUNLESS APPROVED BYOWNER'S REPRESENTATIVE.6.SEE DETAIL FOR BACKFLOW CAGE INSTALLATION.7.ALL BACKFLOW PREVENTION DEVICES SHALL HAVE FREEZE BLANKETINCLUDED UPON INSTALLATION.8.ALL GALVANIZED CONNECTIONS SHALL TO BE MADE USING PIPE THREADSEALANT. ALL SCH. 80 PVC TO GALVANIZED CONNECTIONS TO BE MADEUSING TEFLON TAPE.FLOWDIRECTION12345678910111.BACKFLOW PREVENTIONDEVICE (SEE IRRIGATIONPLANS FOR MAKE ANDMODEL). INSTALL DEVICEPER THE LOCAL WATERPURVEYOR'S STANDARDSAND SPECIFICATION2.GALVANIZED NIPPLE3.4" THICK CONCRETE PAD,1" ABOVE FINISHEDGRADE. SEE BACKFLOWCAGE DETAIL4.CONCRETE THRUSTBLOCKS REQUIRED ONBACKFLOW DEVICES2-1/2" AND LARGER5.BRASS BALL VALVE6.THREADED GALVANIZEDNIPPLE7.GALVANIZED 90O ELBOW8.GALVANIZED UNION9.WRAP 20 MIL TAPE TWICEAROUND GALVANIZED PIPEUNDER FINISHED GRADEAND THROUGH THECONCRETE10.GALVANIZED COUPLING11.SCH 80 PVC MALEADAPTER11L304BACKFLOW PREVENTION DEVICE NTSAROUND GALVANIZED PIPENOTES:1.SEE IRRIGATION LEGEND FOR MAINLINE SIZE AND TYPE.2.ALL SLEEVES SHALL BE SCH. 40 PVC PIPE.3.ALL SLEEVES SHALL EXTEND 12" BEYOND THE EDGE OF PAVEMENT.4.END OF SLEEVES SHALL BE LOCATED WITH A WOODEN STAKE ORPVC PIPE. LOCATORS SHALL RUN CONTINUOUSLY FROM THE END OFTHE SLEEVE TO FINISHED GRADE.1234561.PAVEMENT2.BASE ROCK3.CLEAN BACKFILL, 95% RELATIVECOMPACTION UNDER PAVING OR PERCIVIL ENGINEERS PLANS4.CONTROL WIRES, SLEEVE UNDERPAVING. INSTALL ADJACENT TOPRESSURIZED MAINLINE. BUNDLE SHALLBE NO MORE THAN 50% OF PIPEDIAMETER5.MAINLINE, SLEEVE UNDER PAVING TOBE TWO TIMES THE DIAMETER OF THEPRESSURIZED MAINLINE PIPE6.NON-PRESSURIZED LINE, SLEEVE UNDERPAVING TO BE TWO TIMES THEDIAMETER OF THE LATERAL LINE12L304PIPE BENEATH PAVEMENT NTS3'-0"IRRIGATIONDETAILSL304DATE3084 Thorpe RoadBelgrade, Montana 59714406.924.8038aly@outdoordesignstudios.comISSUEDrawn By: JDChecked By: ARSAH 7TH & ASPEN-PHASE 1 & 2 654 & 706 N. 7Th Ave. Bozeman, MT 597156/28/24 City Submittal