HomeMy WebLinkAbout018 A301 ELEVATIONS - EXTERIOR1. ALUMINUM STOREFRONT SYSTEM, TYP.2. PREFINISHED BRAKE METAL TO MATCH STOREFRONT3. DOOR(S) AND HARDWARE, REFER TO SCHEDULES4. HARDIE BOARD (FINE SAND) PANELS, PAINT TO MATCH 'FOG'5. BRICK, 'MANGANESE IRONSPOT', REFER TO SPECIFICATIONS6. METAL PANEL 'RUSTIC TEXTURE', REFER TO SPECIFICATIONS7. PREFINISHED METAL COPING TO MATCH ADJACENT FINISH8. 42" DEEP PREFINISHED METAL CANOPY TO MATCH STOREFRONT, TYP.9. PICK‐UP WINDOW W/ INTEGRATED AIR CURTAIN10. LINE OF ROOF, BEYOND11. ROOF ACCESS LADDER W/ LOCKING GATE, PAINT 'KNIGHT'S ARMOR'12. OVERFLOW ROOF DRAIN, TYP.13. EMERGENCY EGRESS LIGHTING14. FUTURE SIGNAGE, UNDER SEPARATE PERMIT, SHOWN FOR REFERENCE ONLYEAST:67'‐9" ELEVATION LENGTH, ± 15'‐0" X 2'‐6" SIGN (±37.5 SF)SOUTH:35'‐0" ELEVATION LENGTH, ± 15'‐0" X 2'‐6" SIGN (±37.5 SF)WEST:67'‐9" ELEVATION LENGTH, ±60" DIA. MEDALLION SIGN (±19.6 SF)KEY NOTESXREQUIRED FACADE TRANSPARENCYFOR BUILDINGS DESIGN WITH GROUND LEVEL NON‐RESIDENTIAL USES, AT LEAST 25% OF THE GROUND FLOOR BETWEEN 4'‐8' ABOVE THE SIDEWALK.GROUND FLOOR PERIMETER: 2 x 66'‐7" + 2 x 33'‐11" + 2 x 5'‐1"= 211'‐2"TOTAL PERIMETER AREA 4'‐8' ABOVE SIDEWALK: 4' x 211'‐2"= 845 SFMINIMUM FACADE TRANSPARENCY REQUIRED: 845 SF x 25%= 212 SFEAST FACADE TRANSPARENCY 4'‐8' ABOVE SIDEWALK= 127.75 SFSOUTH FACADE TRANSPARENCY 4'‐8' ABOVE SIDEWALK= 110.00 SFWEST FACADE TRANSPARENCY 4'‐8' ABOVE SIDEWALK= 50.75 SFNORTH FACADE TRANSPARENCY 4'‐8' ABOVE SIDEWALK= 0 SF TOTAL FACADE TRANSPARENCY PROVIDED= 288.50 SF (34.14%)BRICK, 'MANGANESE IRONSPOT'HARDIE BOARD, 'FOG'METAL PANELS 'RUSTIC TEXTURE'FINISH FLOOR0'‐0"T.O. STOREFRONT10'‐0"T.O. PARAPET± 19'‐4"13825471014FINISH FLOOR0'‐0"T.O. STOREFRONT10'‐0"T.O. PARAPET± 19'‐4"T.O. TOWER± 20'‐8"132610144834576101113FINISH FLOOR0'‐0"T.O. STOREFRONT10'‐0"T.O. PARAPET± 19'‐4"T.O. TOWER± 20'‐8"1284576910121214PROVIDENCE DEVELOPMENT1450 TWIN LAKES AVE, SUITE 201BOZEMAN, MT 59718TELEPHONE: 406‐551‐7937Project No.Contents:Revisions:Issue Record:Consultant:HARLAN R. FAUSTARCHITECTDrawn: Checked:Project Manager:#COPYRIGHT 2024THIS DRAWING IS AN INSTRUMENT OF SERVICE AND AS SUCH REMAINS THE PROPERTY OF HARLAN R. FAUST, ARCHITECT. PERMISSION FOR USE OF THIS DOCUMENT IS LIMITED AND CAN BE EXTENDED ONLY BY WRITTEN AGREEMENT WITH HARLAN R. FAUST, ARCHITECT.HARLAN R. FAUST, ARCHITECT14344 "Y" STREETSUITE NO. 204OMAHA, NE 68137-2805TEL: 402.895.0878FAX: 402.895.9561www.fhaarchitects.com04/17/2024 SITE PLAN SUBMITTALPERMIT SUBMITTAL101223ELEVATIONS ‐ EXTERIORA30102/09/2024 CONCEPT SUBMITTAL05/17/2024NWX RESTAURANT SHELL1438 DAYSPRING AVE.BOZEMAN, MT 59718BJF BJFBJF05/31/2024EXT. ELEVATION GENERAL NOTESA. EXPOSED UTILITIES AND CONDUIT/PIPE THAT ARE ALLOWED TO BE PAINTED SHALL MATCH ADJACENT FINISHB. ADDRESS NUMBERS SHALL BE 6" TALL WHITE VINYL ON STOREFRONT UNLESS REQUIRED OTHERWISE BY AHJ1/4" = 1'‐0"A301EXTERIOR ELEVATION ‐ EAST11/4" = 1'‐0"A301EXTERIOR ELEVATION ‐ SOUTH21/4" = 1'‐0"A301EXTERIOR ELEVATION ‐ NORTH31/4" = 1'‐0"A301EXTERIOR ELEVATION ‐ WEST4