HomeMy WebLinkAbout01_LSP_G000 Cover & Egress AssessmentFRIDGE143 SF KITCHEN 006 43 SF MECH 003 534 SF CLASSROOM 001 53 SF ADA BATH 008 43 SF BATH 009 UP DN 29 SF MECH 010 40 SF HALL 007 CLASSROOM 002: Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610 580 SF / 35 = 16 Children + 2 Staff = 18 Occupants Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75' CLASSROOM 001 + BREAK OUT SPACE 011: Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610 620 SF / 35 = 17 Children + 2 Staff = 19 Occupants Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75'EGRESS PATH OF TRAVEL = 40'-8.5"EGRESS PATH OF TRAVEL = 34'-8"EGRESS PATH OF TRAVEL = 47'-6"580 SF CLASSROOM 002 144 SF ENTRY 004 LOWER LEVEL COMBINED OCCUPANT LOAD: Max Floor Area / Child: 35 SF net per MT ARM 37.95.610 1,200 SF / 35 SF = 33 Children + 4 Staff = 37 OCCUPANCY TOTAL** Max Occupant Load for 1 Exit: 49 Max Common Path of Egress Travel = 75' COMMON PATH OF EGRESS TRAVEL = 15'-2" 86 SF BREAK OUT SPACE 011 LOWER LEVEL ** ACTUAL OCCUPANCY NUMBERS WILL BE LESS THAN ALLOWABLE. SEE PROJECT NARRATIVE TABLE 1. 601 SF CLASSROOM 101 154 SF CLASSROOM 102 107 SF CLASSROOM 103 85 SF LAUNDRY 107 193 SF CLASSROOM 104 430 SF GARAGE 108 CLASSROOM 101: Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610 601 SF / 35 = 17 Children + 2 Staff Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75' CLASSROOMS 102 and 103*: Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610 154 SF / 35 = 4 Children + 1 Staff 107 SF / 35 = 3* *Classrooms 102 and 103 will be used together to serve 4 babies total with the MT ARM 37.95.623 4:1 child-to-staff ratio limiting the occupancy Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75' CLASSROOM 104: Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610 193 SF / 35 = 5 Children + 1 Staff Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75' 63 SF ENTRY 100 DN DN RAMP SLOPE 1:12 MT ARM 37.95.610 SF REQ'S IBC 2021 E OCCUPANCY EGRESS REQ'S MAX EGRESS PATH OF TRAVEL = 53'-8"MAIN LEVEL COMBINED OCCUPANT LOAD: Max Floor Area / Child: 35 SF net per MT ARM 37.95.610 1,055 SF / 35 SF = 30 Children + 4 Staff = 34 MAX OCCUPANCY TOTAL** Max Occupant Load for 1 Exit: 49 Max Common Path of Egress Travel = 75' MAIN LEVEL PLOT DATE:Design 212 S. WALLACE AVE STE. 301 BOZEMAN, MT tel. 406 -414 -7744 THRULINEPARTNERS.COM APPROVED BY: REVISION LOG REV # DATE DRAWN BY: SHEET NO. SHEET TITLE CLIENT NAMEPROJECT ADDRESSPERMIT NUMBER:FILE PATH:to Build Project No. DATE ISSUED:PAGE SIZE: ANSI D (22 X 34)03/01/24 1 09.08.2023 SP PERMIT RESUBMIT 12.06.2023 BUILDING PERMIT SET2 23167 03.01.2024 MOD APP SET3 2/28/2024 3:05:20 PMBIM 360://LSP/23.003_LSP_r21.rvtCOVER & EGRESS ASSESSMENT LLG G000 Viviana Helvik130 Flanders Mill Rd. Bozeman, MT 59718LGLITTLE SPANISHPRESCHOOL23.003 VIVIANA HELVIK OWNERS ALPINE SURVEYING & ENGINEERING, INC CIVIL ENGINEER714 STONERIDGE DRIVE, SUITE 3 BOZEMAN, MONTANA 59718 (E) clitle@alpinesurveying.net (P) 406.586.5599 CONTACT: Clint Litle, PE G000 COVER & EGRESS ASSESSMENT C1.0 CIVIL AND UTILITY PLAN C2.0 GRADING PLAN L1.0 SITE OVERVIEW L2.1 PLANTING PLAN L3.0 IRRIGATION PLAN A101 PLAN - SITE A201 PLAN - LOWER LEVEL A202 PLAN - MAIN LEVEL A301 ELEVATION - EXTERIOR EXISTING A302 ELEVATION - EXTERIOR EXISTING A303 ELEVATION - EXTERIOR EXISTING A304 ELEVATION - EXTERIOR A305 ELEVATION - EXTERIOR The modification to our project will be to convert the approximately 4,000 SF two story single family home built in 2003 into a single commercial daycare center operating on both levels of the building, rather than the main level residence with a group home daycare and a lower level commercial daycare center as initially proposed. The building will have a single occupancy classification of Group E for the daycare center operation. DESIGN CRITERIA ADDRESS: LEGAL DESCRIPTION: ZONING: 130 Flanders Mill Road Bozeman MT, 59718 S03, T02 S, R05 E, C.O.S. 2360, PARCEL 1, ACRES 1.088 R-3 1.088 acres; 47,393 SF 15 FT 97'-1-1/4" FT (AT GARAGE - NO CHANGE) 5FT EA. SIDE (NO CHANGE) 20 FT (NO CHANGE) 46 FT w/ 8:12 ROOF PITCH 23'-2-1/2" (GRADE at FRONT to T.O. RIDGE - NO CHANGE) LOT AREA: REQUIRED FRONT SETBACK: PROVIDED FRONT SETBACK: REQUIRED SIDE SETBACK: PROVIDED SIDE SETBACK: REQUIRED REAR SETBACK: PROVIDED REAR SETBACK: ALLOWABLE HEIGHT: EXISTING HEIGHT: CITY OF BOZEMAN, GALLATIN COUNTY MT ARM Amendments to adopted codes 2021 INTERNATIONAL BUILDING CODE (IBC) 2021 INTERNATIONAL MECHANICAL CODE (IMC) 2021 INTERNATIONAL FUEL GAS CODE (IFGC) 2021 UNIFORM PLUMBING CODE (UPC) (IAPMO) 2020 NATIONAL ELECTRICAL CODE (NEC) 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2021 INTERNATIONAL FIRE CODE ICC A117.1-2017 STANDARD FOR ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES PROJECT TEAM 410 WESTGATE AVE BOZEMAN, MONTANA 59718 (E) lsp.bozeman@gmail.com (P) 406.579.1443 ZONING ANALYSISPROJECT LOCATION LITTLE SPANISH PRESCHOOL BOZEMAN, MONTANA DRAWING INDEX MOD Application Set (dated 03.01.2024) SCOPE OF WORK NORTH THRULINE PARTNERS, LLC ARCHITECT212 SOUTH WALLACE AVENUE, SUITE 301 BOZEMAN, MONTANA 59715 (E) lotus@thrulinepartners.com (P) 406.600.9677 CONTACT: Lotus Grenier, RA SITE EGRESS ASSESSMENT 1/8" = 1'-0"1 PLAN - EGRESS ASSESSMENTS DESIGNATION # OF SPACES LOCATION DAYCARE (1 PER 15) 3.9 ON-SITE PARKING PER PLAN STAFF 8 ON-SITE PARKING PER PLAN & GARAGE TOTAL REQ'D 11.9 PARKING REDUCTION - 1.19 BICYCLE SPACES IN LIEU OF PARKING - 1.19 LANDSCAPING IN LIEU OF PARKING TOTAL 9.52 SECTION BMC 38.540.050 - FRACTIONAL SPACES TOTAL REQ'D 9 PARKING ASSESSMENT **DESIGNATIONS PER BMC 38.540.050 AND OCCUPANCY CALCULATION ON PG. 2 OF PROJECT NARRATIVE LEVEL/LOCATION AREA DAYCARE (Main Level) 1767 SF GARAGE (Main Level) 459 SF DAYCARE (Lower Level) 1868 SF SQUARE FOOTAGE TOTAL 4,094 GROSS SQ FT N BIG SKY STRUCTURAL SOLUTIONS, PLLC STRUCTURAL ENGINEERP.O. BOX 11658 BOZEMAN, MONTANA 59719 (E) bmay.bs3@gmail.com (P) 412.722.3938 CONTACT: Brian May, PE BYLA LANDSCAPE ARCHITECT113 E. OAK ST. STE. 2C BOZEMAN, MONTANA 59715 (E) brent@byla.us (P) 406.312.9870 CONTACT: Brent Jacobsen, LA L2.1 PLANTING PLAN L3.0 IRRIGATION PLAN A101 PLAN - SITE A201 PLAN - LOWER LEVEL A202 PLAN - MAIN LEVEL A301 ELEVATION - EXTERIOR EXISTING A302 ELEVATION - EXTERIOR EXISTING A303 ELEVATION - EXTERIOR EXISTING A304 ELEVATION - EXTERIOR A305 ELEVATION - EXTERIOR L3.0 IRRIGATION PLAN A101 PLAN - SITE A201 PLAN - LOWER LEVEL A202 PLAN - MAIN LEVEL A301 ELEVATION - EXTERIOR EXISTING A302 ELEVATION - EXTERIOR EXISTING A303 ELEVATION - EXTERIOR EXISTING A304 ELEVATION - EXTERIOR A305 ELEVATION - EXTERIOR L3.0 IRRIGATION PLAN A101 PLAN - SITE A201 PLAN - LOWER LEVEL A202 PLAN - MAIN LEVEL A301 ELEVATION - EXTERIOR EXISTING A302 ELEVATION - EXTERIOR EXISTING A303 ELEVATION - EXTERIOR EXISTING A304 ELEVATION - EXTERIOR A305 ELEVATION - EXTERIOR