HomeMy WebLinkAbout01_LSP_G000 Cover & Egress AssessmentFRIDGE143 SF
KITCHEN
006
43 SF
MECH
003
534 SF
CLASSROOM
001
53 SF
ADA BATH
008
43 SF
BATH
009
UP
DN
29 SF
MECH
010 40 SF
HALL
007
CLASSROOM 002:
Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610
580 SF / 35 = 16 Children + 2 Staff = 18 Occupants
Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75'
CLASSROOM 001 + BREAK OUT SPACE 011:
Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610
620 SF / 35 = 17 Children + 2 Staff = 19 Occupants
Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75'EGRESS PATH OF TRAVEL = 40'-8.5"EGRESS PATH OF TRAVEL = 34'-8"EGRESS PATH OF TRAVEL = 47'-6"580 SF
CLASSROOM
002
144 SF
ENTRY
004
LOWER LEVEL COMBINED OCCUPANT LOAD:
Max Floor Area / Child: 35 SF net per MT ARM 37.95.610
1,200 SF / 35 SF = 33 Children + 4 Staff =
37 OCCUPANCY TOTAL**
Max Occupant Load for 1 Exit: 49
Max Common Path of Egress Travel = 75'
COMMON PATH OF
EGRESS TRAVEL =
15'-2"
86 SF
BREAK OUT
SPACE
011
LOWER LEVEL
** ACTUAL OCCUPANCY NUMBERS WILL BE LESS THAN
ALLOWABLE. SEE PROJECT NARRATIVE TABLE 1.
601 SF
CLASSROOM
101
154 SF
CLASSROOM
102
107 SF
CLASSROOM
103
85 SF
LAUNDRY
107
193 SF
CLASSROOM
104
430 SF
GARAGE
108
CLASSROOM 101:
Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610
601 SF / 35 = 17 Children + 2 Staff
Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75'
CLASSROOMS 102 and 103*:
Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610
154 SF / 35 = 4 Children + 1 Staff
107 SF / 35 = 3*
*Classrooms 102 and 103 will be used together to serve 4 babies
total with the MT ARM 37.95.623 4:1 child-to-staff ratio limiting the
occupancy
Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75'
CLASSROOM 104:
Max Floor Area / Child: 35 SF Net per MT ARM 37.95.610
193 SF / 35 = 5 Children + 1 Staff
Max Egress Path of Travel for 1 Exit with Occupant Load < 30 = 75'
63 SF
ENTRY
100
DN
DN
RAMP SLOPE 1:12
MT ARM 37.95.610 SF REQ'S
IBC 2021 E OCCUPANCY EGRESS REQ'S
MAX EGRESS PATH OF TRAVEL = 53'-8"MAIN LEVEL COMBINED OCCUPANT LOAD:
Max Floor Area / Child: 35 SF net per MT ARM 37.95.610
1,055 SF / 35 SF = 30 Children + 4 Staff =
34 MAX OCCUPANCY TOTAL**
Max Occupant Load for 1 Exit: 49
Max Common Path of Egress Travel = 75'
MAIN LEVEL
PLOT DATE:Design
212 S. WALLACE AVE STE. 301
BOZEMAN, MT
tel. 406 -414 -7744
THRULINEPARTNERS.COM
APPROVED BY:
REVISION LOG
REV # DATE
DRAWN BY:
SHEET NO.
SHEET TITLE CLIENT NAMEPROJECT ADDRESSPERMIT NUMBER:FILE PATH:to Build
Project No.
DATE ISSUED:PAGE SIZE: ANSI D (22 X 34)03/01/24
1 09.08.2023 SP PERMIT RESUBMIT
12.06.2023 BUILDING PERMIT SET2
23167
03.01.2024 MOD APP SET3
2/28/2024 3:05:20 PMBIM 360://LSP/23.003_LSP_r21.rvtCOVER & EGRESS
ASSESSMENT
LLG
G000 Viviana Helvik130 Flanders Mill Rd. Bozeman, MT 59718LGLITTLE SPANISHPRESCHOOL23.003
VIVIANA HELVIK
OWNERS
ALPINE SURVEYING & ENGINEERING, INC
CIVIL ENGINEER714 STONERIDGE DRIVE, SUITE 3
BOZEMAN, MONTANA 59718
(E) clitle@alpinesurveying.net
(P) 406.586.5599
CONTACT: Clint Litle, PE
G000 COVER & EGRESS ASSESSMENT
C1.0 CIVIL AND UTILITY PLAN
C2.0 GRADING PLAN
L1.0 SITE OVERVIEW
L2.1 PLANTING PLAN
L3.0 IRRIGATION PLAN
A101 PLAN - SITE
A201 PLAN - LOWER LEVEL
A202 PLAN - MAIN LEVEL
A301 ELEVATION - EXTERIOR EXISTING
A302 ELEVATION - EXTERIOR EXISTING
A303 ELEVATION - EXTERIOR EXISTING
A304 ELEVATION - EXTERIOR
A305 ELEVATION - EXTERIOR
The modification to our project will be to convert the
approximately 4,000 SF two story single family home built in
2003 into a single commercial daycare center operating on
both levels of the building, rather than the main level residence
with a group home daycare and a lower level commercial
daycare center as initially proposed. The building will have a
single occupancy classification of Group E for the daycare
center operation.
DESIGN CRITERIA
ADDRESS:
LEGAL DESCRIPTION:
ZONING:
130 Flanders Mill Road
Bozeman MT, 59718
S03, T02 S, R05 E, C.O.S. 2360,
PARCEL 1, ACRES 1.088
R-3
1.088 acres; 47,393 SF
15 FT
97'-1-1/4" FT (AT GARAGE - NO CHANGE)
5FT EA. SIDE
(NO CHANGE)
20 FT
(NO CHANGE)
46 FT w/ 8:12 ROOF PITCH
23'-2-1/2" (GRADE at FRONT to T.O. RIDGE - NO CHANGE)
LOT AREA:
REQUIRED FRONT SETBACK:
PROVIDED FRONT SETBACK:
REQUIRED SIDE SETBACK:
PROVIDED SIDE SETBACK:
REQUIRED REAR SETBACK:
PROVIDED REAR SETBACK:
ALLOWABLE HEIGHT:
EXISTING HEIGHT:
CITY OF BOZEMAN, GALLATIN COUNTY
MT ARM Amendments to adopted codes
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2021 INTERNATIONAL FUEL GAS CODE (IFGC)
2021 UNIFORM PLUMBING CODE (UPC) (IAPMO)
2020 NATIONAL ELECTRICAL CODE (NEC)
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2021 INTERNATIONAL FIRE CODE
ICC A117.1-2017 STANDARD FOR ACCESSIBLE AND USEABLE BUILDINGS
AND FACILITIES
PROJECT TEAM
410 WESTGATE AVE
BOZEMAN, MONTANA 59718
(E) lsp.bozeman@gmail.com
(P) 406.579.1443
ZONING ANALYSISPROJECT LOCATION
LITTLE SPANISH PRESCHOOL
BOZEMAN, MONTANA
DRAWING INDEX
MOD Application Set (dated 03.01.2024)
SCOPE OF WORK
NORTH
THRULINE PARTNERS, LLC
ARCHITECT212 SOUTH WALLACE AVENUE, SUITE 301
BOZEMAN, MONTANA 59715
(E) lotus@thrulinepartners.com
(P) 406.600.9677
CONTACT: Lotus Grenier, RA
SITE
EGRESS ASSESSMENT
1/8" = 1'-0"1 PLAN - EGRESS ASSESSMENTS
DESIGNATION # OF SPACES LOCATION
DAYCARE (1 PER 15) 3.9 ON-SITE PARKING PER PLAN
STAFF 8 ON-SITE PARKING PER PLAN & GARAGE
TOTAL REQ'D 11.9
PARKING REDUCTION - 1.19 BICYCLE SPACES IN LIEU OF PARKING
- 1.19 LANDSCAPING IN LIEU OF PARKING
TOTAL 9.52 SECTION BMC 38.540.050 - FRACTIONAL SPACES
TOTAL REQ'D 9
PARKING ASSESSMENT
**DESIGNATIONS PER BMC 38.540.050 AND OCCUPANCY CALCULATION ON PG. 2 OF PROJECT NARRATIVE
LEVEL/LOCATION AREA
DAYCARE (Main Level) 1767 SF
GARAGE (Main Level) 459 SF
DAYCARE (Lower Level) 1868 SF
SQUARE FOOTAGE
TOTAL 4,094 GROSS SQ FT
N
BIG SKY STRUCTURAL SOLUTIONS, PLLC
STRUCTURAL ENGINEERP.O. BOX 11658
BOZEMAN, MONTANA 59719
(E) bmay.bs3@gmail.com
(P) 412.722.3938
CONTACT: Brian May, PE
BYLA
LANDSCAPE ARCHITECT113 E. OAK ST. STE. 2C
BOZEMAN, MONTANA 59715
(E) brent@byla.us
(P) 406.312.9870
CONTACT: Brent Jacobsen, LA
L2.1 PLANTING PLAN
L3.0 IRRIGATION PLAN
A101 PLAN - SITE
A201 PLAN - LOWER LEVEL
A202 PLAN - MAIN LEVEL
A301 ELEVATION - EXTERIOR EXISTING
A302 ELEVATION - EXTERIOR EXISTING
A303 ELEVATION - EXTERIOR EXISTING
A304 ELEVATION - EXTERIOR
A305 ELEVATION - EXTERIOR
L3.0 IRRIGATION PLAN
A101 PLAN - SITE
A201 PLAN - LOWER LEVEL
A202 PLAN - MAIN LEVEL
A301 ELEVATION - EXTERIOR EXISTING
A302 ELEVATION - EXTERIOR EXISTING
A303 ELEVATION - EXTERIOR EXISTING
A304 ELEVATION - EXTERIOR
A305 ELEVATION - EXTERIOR
L3.0 IRRIGATION PLAN
A101 PLAN - SITE
A201 PLAN - LOWER LEVEL
A202 PLAN - MAIN LEVEL
A301 ELEVATION - EXTERIOR EXISTING
A302 ELEVATION - EXTERIOR EXISTING
A303 ELEVATION - EXTERIOR EXISTING
A304 ELEVATION - EXTERIOR
A305 ELEVATION - EXTERIOR