Loading...
HomeMy WebLinkAboutstruct coversheetA.B. ANCHOR BOLT B. FRM BRACE FRAME BLKG.BLOCKING B.O.BOTTOM OF BRG.BEARING BTM.BOTTOM B.U.BUILT-UP C-CHANNEL 'C'-SECTION CANT.CANTILEVER CJ COLD JOINT C.M.U.CONCRETE MASONRY UNIT COL.COLUMN CONC.CONCRETE CONT.CONTINUOUS CVR.COVER DBL.DOUBLE DIA.DIAMETER DIAPH.DIAPHRAGM DIM.DIMENSION DP.DEEP DTL DETAIL (E)EXISTING ELEV.ELEVATION EPXY. EPOXY EF EACH FACE E.W.EACH WAY EXP. EXPANSION F.B.M. FLOOR BEAM F.G. FULLY GROUTED F.J. FLOOR JOIST FND FOUNDATION FS FOOTING STEP FT. FEET FTG FOOTING GL GLU-LAMINATED GS GUNSTOCKED TO (2x6) HD HOLDOWN HDR. HEADER H.F.HEEL FACE HSS HOLLOW STRUCTURAL SECTION I.D.INSIDE DIAMETER I.F.INSIDE FACE IN.INCHES K.KNIFE K.KNEE WALL L-STEEL ANGLE 'L'-SECTION LVL LAMINATED VENEER LUMBER M.B.MACHINE BOLT M. FRM MOMENT FRAME MNFR.MANUFACTURER (N)NEW O.C.ON CENTER O.D.OUTSIDE DIAMETER O.F.OUTSIDE FACE O.H.OFF-HAND OSB ORIENTED STRAND BOARD P.A.F.POWER ACTUATED FASTENER P. ENG.PRE-ENGINEERED PL.PLACE/PLACES PLYWD PLYWOOD PSL PARALLEL STRAND LUMBER P.T.PRESERVATIVE-TREATED R.B.M.ROOF BEAM REINF.REINFORCING REV.REVISION S & G SCREW & GLUE SCHED.SCHEDULE SIM.SIMILAR SIMP.SIMPSON SJ SLAB JOINT S.O.G SLAB ON GRADE STFNR.STIFFENER STL STEEL STL. DKG. STEEL DECKING S.W. SHEAR WALL SYM. SYMMETRICAL THRD THREADED T.F.TOE FACE T.N. TOE NAIL T.O. TOP OF TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE VLY. VALLEY W-WIDE FLANGE BEAM w/ WITH WD WOOD WD. WIDE WS WALL STEP W.H.S.WELDED HEADED STUD W.T.S.WELDED THREADED STUD W.W.F. WELDED WIRE FABRIC F# GENERAL NOTES ACRONYMS SYMBOLS INDICATES FOOTING MARK (SEE FOOTING SCHEDULE FOR ADD'L INFO) C#INDICATES CONCRETE WALL (SEE CONC. WALL SCHED. FOR ADD'L INFO) X INDICATES SHEAR WALL, SEE SHEAR WALL SCHEDULE FOR ADD'L INFO. (SHEAR WALL MARK APPLIES TO ENTIRE WALL LINE) INDICATES COLUMN, SEE COLUMN SCHEDULE FOR ADD'L INFO. INDICATES HOLDOWN LOCATION, SEE HOLD DOWN SCHEDULE FOR ADD'L INFO SPOT ELEVATION SYMBOL ⌀DIAMETER ℄CENTERLINE Р PLATE FILLET WELD SQUARE GROOVE WELD FLARE BEVEL WELD BEVEL WELD INDICATES FIELD WELD INDICATES WELD ALL-AROUND x y@z x -INDICATES WELD LEG SIZE y -INDICATES WELD LENGTH z -INDICATES WELD SPACING (IN.) x x INDICATES DOWEL REINFORCING AND DIMENSIONS X X.X INDICATES CALLOUT MARKER X -INDICATES DETAIL # X.X -INDICATES SHEET LOCATION X X.X INDICATES WALL SECTION MARKER X -INDICATES DETAIL # X.X -INDICATES SHEET NUMBER X X.X INDICATES WALL ELEVATION MARKER X -INDICATES DETAIL # X.X -INDICATES SHEET NUMBER HATCHES CONCRETE STEEL (SECTION, PLAN) CMU PLYWOOD NON-SHRINK GROUT OVERFRAMING, U.N.O. COMPACTED EARTH INDICATES FOOTING STEP INDICATES FOUNDATION WALL STEP F S W SC-##M#INDICATES MASONRY WALL (SEE MASONRY WALL SCHED. FOR ADD'L INFO) INDICATES CONCRETE PIER, SEE PIER SCHEDULE FOR ADD'L INFO.P##SHEAR WALL BEARING WALL INDICATES DIAPHRAGM (ARROW INDICATES SHEATHING SPAN DIRECTION) SEE DIAPHRAGM SCHEDULE FOR ADD'L INFO. X #B-#INDICATES BEAM, SEE BEAM SCHEDULE FOR ADD'L INFO. L-#INDICATES LEDGER, SEE LEDGER SCHEDULE FOR ADD'L INFO. HD# GENERAL THIS PROJECT IS TO CONFORM TO THE 2021 EDITION OF THE INTERNATIONAL RESIDENTIAL/BUILDING CODE AND ANY LOCAL AMENDMENTS TO THIS CODE. USE DETAILS MARKED "TYPICAL" WHEREVER THEY APPLY. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AT THE SITE BEFORE PROCEEDING. CHANGES, OMISSIONS OR SUBSTITUTIONS ARE NOT PERMITTED WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT AND STRUCTURAL ENGINEER. THESE DRAWINGS INDICATE THE FINISHED PRODUCT. ANY TEMPORARY BRACING, SHORING, OR PRE-LOADING REQUIRED DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING CONSTRUCTION LOADS TO 20 PSF. (STRUCTURAL DRAWINGS ARE INTENDED TO BE USED WITH DRAWINGS FROM OTHER DISCIPLINES. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE REQUIREMENTS OF EACH DISCIPLINE IN THE WORK AND SHOP DRAWINGS.) SHOP DRAWINGS SHOP DRAWINGS TO BE CHECKED AND APPROVED BY THE GENERAL CONTRACTOR PRIOR TO SUBMITTING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW. DESIGN LOADS GRAVITY ROOF DEAD LOAD =20 PSF FLOOR DEAD LOAD =20 PSF WALL DEAD LOAD =15 PSF ROOF LIVE LOAD =20 PSF FLOOR LIVE LOAD =40 PSF STAIR LIVE LOAD =40 PSF; 300 LB CONCENTRATED LOAD GROUND SNOW LOAD =46 PSF ROOF SNOW LOAD =41 PSF OBSTRUCTED (8:12) FOUNDATIONS FOOTING BEARING PRESSURES ARE LIMITED TO 1500 PSF AS A RESULT OF NO GEOTECH REPORT. FOOTINGS AROUND THE PERIMETER OR IN UNHEATED AREAS ARE TO BEAR A MINIMUM OF 48" BELOW FINISH GRADE UNLESS OTHERWISE SHOWN ON THE DRAWINGS. BOTTOM OF ALL FOOTINGS TO BEAR ON NATIVE, INORGANIC, UNDISTURBED SOIL A MINIMUM OF 1'-0" BELOW EXISTING GRADE OR ON SELECT, COMPACTED, STRUCTURAL FILL. SEE SOILS REPORT FOR REQUIREMENTS. BACKFILL UNDER SLABS ON GRADE AND SIDEWALKS IS TO CONSIST OF GRANULAR SOIL MATERIAL AND COMPACTED TO MIN. OF 95% OF ITS MAXIMUM DENSITY (ASTM D698). CAST-IN-PLACE CONCRETE ATTAIN A MINIMUM 28 DAY COMPRESSION STRENGTH OF 4000 PSI FOR FOOTINGS, 4000 PSI FOR SLABS, WALLS, BEAMS, AND COLUMNS, AND 3500 PSI FOR PORCHES, CARPORT SLABS, STEPS EXPOSED TO WEATHER, AND GARAGE FLOOR SLABS. PROVIDE MAXIMUM SLUMPS AS FOLLOWS: 3" FOR SLABS AND FOOTINGS; 4" FOR WALLS, BEAMS AND COLUMNS. CONSTRUCTION TO BE IN ACCORDANCE WITH ACI 318 "PART 2 -STANDARDS FOR TESTS AND MATERIALS" AND "PART 3 -CONSTRUCTION REQUIREMENTS". CONCRETE ADHESIVE SHALL BE "HILTI HIT HY-200V3" (ICC-ES NO. 4868) OR APPROVED EQUAL. INSTALL ADHESIVE ANCHORS PER MANUFACTURER'S RECOMMENDATIONS. REINFORCEMENT USE DEFORMED STEEL BARS CONFORMING TO ASTM A615 GRADE 60 TYPICAL EXCEPT AS FOLLOWS: -IF #3 BARS, STIRRUPS, TIES, AND FIELD BENT DOWELS, DEFORMED STEEL BARS SHALL BE GRADE 40. -IF WELDING STEEL BARS TO STRUCTURAL SHAPES, PLATES, ANGLES AND CHANNELS, DEFORMED STEEL BARS SHALL BE CONFORMING TO ASTM A706 GRADE 60 -WELDED WIRE FABRIC SHALL CONFORM TO ASTM A82 OR A185 AND SHALL BE PROVIDED IN FLAT SHEETS. REINFORCING IS TO BE SUPPORTED ON CHAIRS OR CONCRETE BRICKS AND SECURELY TIED IN PLACE. PROVIDE CLEAR COVER AS SHOWN ON PLANS OR AS FOLLOWS: 1.CONCRETE POURED DIRECTLY AGAINST SOIL (i.e. BOTTOM OF FOOTINGS): 3" COVER 2.FORMED CONCRETE IN CONTACT WITH SOIL (i.e. FOUNDATION WALLS, PIERS): 2" COVER 3.INTERIOR COLUMNS AND BEAMS: 1 1/2" COVER 4.WALLS EXPOSED TO WEATHER: 2" COVER 5.WALLS NOT EXPOSED TO WEATHER: 1 1/2" COVER 6.SLABS-ON-GRADE: 2" COVER (EXTERIOR), 1 1/2" COVER (INTERIOR) 7.ELEVATED SLAB: PER SLAB SPECIFICATIONS REINFORCING STEEL SHALL NOT BE WELDED UNLESS PRIOR WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. SUBMIT SHOP DRAWINGS OF REINFORCING STEEL FOR REVIEW BY THE ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO FABRICATION. OPTION: USE "CAPROLAN-RC" CONFORMING TO ASTM C-1116 OR APPROVED EQUAL 100% VIRGIN MONOFILAMENT FIBERS, AT A RATE OF 1 POUND PER CUBIC YARD OF CONCRETE AT SLABS ON GRADE UNLESS NOTED OTHERWISE. COORDINATE WITH E.O.R. IF THIS OPTION IS REQUESTED IN LIEU OF SPECIFIED REINFORCEMENT. STRUCTURAL STEEL STRUCTURAL SHAPES TO CONFORM TO ASTM A992/A572-50, FY = 50 KSI. STRUCTURAL TUBING: ASTM A500, FY = 46 KSI; STEEL PIPE: ASTM A53 OR A501, FY = 35 KSI. MISCELLANEOUS CONNECTION PLATES, ANGLES AND CHANNELS TO CONFORM TO ASTM A36, FY = 36 KSI MINIMUM. STEEL IS TO BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC "SPECIFICATIONS FOR DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL BUILDINGS". ALL WELDING IS TO BE PERFORMED BY AWS CERTIFIED WELDERS USING E70XX ELECTRODES. BOLTS: ASTM A325 HIGH STRENGTH BOLTS (H.S.B.). UNLESS NOTED AS ASTM A307 (M.B.); ANCHOR BOLTS (A.B.): F1154 GR 36 (OR GR. 55), EXPANSION BOLTS IN CONCRETE (E.B.): "HILTI KB-TZ2" (ICC-ES REPORT NO. 4266) OR APPROVED EQUAL. POWDER ACTUATED FASTENERS (P.A.F.) "HILTI DX POWDER ACTUATED FASTENERS TYPE X-DN1" OR APPROVED EQUAL. INSTALL EXPANSION BOLTS, ADHESIVE ANCHORS, AND POWDER ACTUATED FASTENERS PER MANUFACTURER'S RECOMMENDATIONS. ALL COLUMNS AND BEAMS TO BE FROM UNSPLICED LENGTHS UNLESS OTHERWISE NOTED ON THE DRAWINGS. SUBMIT SHOP DRAWINGS SHOWING SIZES, DIMENSIONS AND REQUIRED CONNECTION DETAILS FOR REVIEW BY THE ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO FABRICATION. WOOD 1.SAWN LUMBER, PER WWPA GRADING RULES A.BEAMS, HEADERS, STUDS, BUILT-UP COLUMNS: DOUGLAS FIR-LARCH #2 (DF-L #2), OR BETTER B.COLUMNS (NOT BUILT-UP): DOUGLAS FIR-LARCH #1 (DF-L #1), OR BETTER 2.RLT (RECLAIMED TIMBER) HAVE BEEN SIZED ACCORDING TO THE FOLLOWING MATERIAL PROPERTIES (EQUIVALENT TO HEM-FIR #2) A.2" TO 4" THICK MEMBERS: Fb=850 psi, Ft=525 psi, Fv=150 psi, Fc,PERP.=405 psi, Fc,PARALLEL=1300 psi, E=1300 ksi B.BEAMS & STRINGERS: Fb=675 psi, Ft=350 psi, Fv=140 psi, Fc,PERP.=405 psi, E=1100 ksi C.POSTS & COLUMNS: Fb=575 psi, Ft=375 psi, Fv=140 psi, Fc,PERP.=405 psi, Fc,PARALLEL=575 psi, E=1100 ksi 3.GLU-LAMS (GLUE-LAMINATED SOFTWOOD TIMBERS): A.SIMPLE SPAN BEAMS: DF/DF 24F-V4 B.CONTINUOUS OR CANTILEVERED BEAMS: DF/DF 24F-V8 4.PSL (PARALLEL STRAND LUMBER): A.HEADERS AND BEAMS: TRUS JOIST MACMILLAN 2.0E PARALLAM PSL, Fb=2900 psi B.COLUMNS AND POSTS: TRUS JOIST MACMILLAN 1.8E PARALLAM PSL, Fb=2400 psi 5.LVL (LAMINATED VENEER LUMBER): A.HEADERS AND BEAMS: TRUS JOIST MACMILLAN 2.0E MICROLAM LVL, Fb=2600 psi 6.PLYWOOD WEB JOISTS: TRUS JOIST MACMILLAN "TJI", SIZE AND SERIES AS INDICATED IN FRAMING PLANS. ALL PLYWOOD WEB JOISTS SHALL HAVE LOAD CARRYING CAPACITY IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED LOAD TABLES. INSTALL ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. PRODUCTS MAY BE SUBSTITUTED UPON REVIEW BY THE ARCHITECT AND STRUCTURAL ENGINEER. SUBMIT SHOP DRAWINGS OF LAYOUT AND REQUIRED CONNECTION DETAILS FOR REVIEW BY THE ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO FABRICATION. 7.RIM JOISTS: TRUS JOIST MACMILLAN 1.3E TIMBERSTRAND LSL, Fc,PERP.=710 psi 8.PLYWOOD SHEATHING: C-D, INT-APA WITH EXTERIOR GLUE. PLYWOOD/OSB SHEATHING: APA STRUCTURAL I, SHEATHING GRADE WITH EXTERIOR GLUE. 9.WOOD FRAMING ANCHORS AND CONNECTORS: "SIMPSON" OR APPROVED EQUAL AS INDICATED ON DRAWINGS. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. FOR NAILING NOT SHOWN ON THE DRAWINGS, USE I.B.C. NAILING SCHEDULE, TABLE NO. 2304.91. 10.DECAY PROTECTION: WHERE STRUCTURAL WOOD FRAMING ELEMENTS (NOT LIMITED TO SILL PLATES, WALL STUDS, POSTS, BEAMS, AND WALL SHEATHING) ARE NOT A MINIMUM 6" ABOVE FINISH GRADE, PRESERVATIVE TREATED FRAMING MATERIALS AND CORRESPONDING PROTECTED FASTENERS SHALL BE USED UNLESS APPORVED WATERPOOFING DETAIL IS USED (WATERPROOFING BY OTHER) GENERAL CONSTRUCTION NOTES GENERAL CONSTRUCTION NOTES CONT... PRESERVATIVE TREATED WOOD PRESERVATIVE TREATED WOOD SHALL BE USED IN THE FOLLOWING CONDITIONS; IN CONTACT WITH CONCRETE (i.e. FOUNDATION WALLS, SLABS, ETC.), MASONRY EXTERIOR-WET CONDITIONS (i.e. HIGH MOISTURE AND RAINFALL ENVIRONMENTS), OR IN CONTACT WITH SOIL. ALL SIMPSON HANGERS/FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. NOTE: FASTENER TYPE/COATING SHALL MATCH HANGER TYPE/COATING (e.g. USE G90 GALVANIZED FASTENERS WITH G90 GALVANIZED HANGERS), USE TABLE 1, 'CONNECTOR COATING RECOMMENDATION-STRUCTURAL APPLICATIONS.' BELOW TO SELECT REQUIRED COATING: LOW = USE STANDARD PAINTED AND G90 GALVANIZED CONNECTORS, OR SIMPSON STRONG-TIE STRONG DRIVE SCREWS (SDS) WITH THE DOUBLE-BARRIER COATING, AS A MINIMUM MED = USE ZMAX/HDG GALVANIZED CONNECTORS AS A MINIMUM. USE HDG FASTENERS WHICH MEET THE SPECIFICATIONS OF ASTM A153 OR SIMPSON STRONG-TIE STRONG DRIVE SCREWS (SDS) WITH DOUBLE-BARRIER COATING. HIGH '6' = USE TYPE 303, 304, 305 OR 316 STAINLESS-STEEL CONNECTORS AND FASTENERS. TABLE 1: CONNECTOR COATING RECOMMENDATION - STRUCTURAL APPLICATIONS ENVIRONMENT UNTREATED WOOD SBX/DOT & ZINC BORATE MCQ ACQ-C, ACQ-D (CARBONATE). CA-B, CA-C & CBA-A NO AMMONIA WITH AMMONIA HIGHER CHEMICAL CONTENT1 ACZA OTHER OR UNCERTAIN INTERIOR -DRY NOT NEEDED LOW LOW5 MED5 MED HIGH HIGH HIGH EXTERIOR -DRY LOW N/A2 MED MED HIGH HIGH HIGH HIGH EXTERIOR -WET MED MED3,4 MED3,4 HIGH HIGH HIGH HIGH EXPOSURE HIGH HIGH HIGH HIGH HIGH HIGH UNCERTAIN HIGH HIGH HIGH HIGH HIGH HIGH N/A2 N/A2 N/A2 HIGH HIGH HIGH 1.WOODS WITH ACTUAL RETENTION LEVELS GREATED THAN 0.40 PCF FOR ACQ AND MCQ, 0.41 PCF FOR CBA-A, OR 0.21 PCF FOR CA-B (GROUND CONTACT LEVEL). 2.BORATE TREATED WOODS ARE NOT APPROPRIATE FOR OUTDOOR USE. 3.TEST RESULTS INDICATE THAT ZMAX/HDG AND SDS DOUBLE-BARRIER COATING WILL PERFORM ADEQUATELY, SUBJECT TO REGULAR MAINTENANCE AND PERIODIC INSPECTION. HOWEVER, THE NATIONALLY-APPROVED TEST METHOD USED, AWPA E12-94 IS AN ACCELERATED TEST, SO DATA OVER AN EXTENDED PERIOD OF TIME IS NOT AVAILABLE. IF UNCERTAIN, USE STAINLESS STEEL. 4.SOME TREATED WOOD MAY HAVE EXCESS SURFACE CHEMICALS MAKING IT POTENTIALLY MORE CORROSIVE. IF YOU SUSPECT THIS OR ARE UNCERTAIN, USE STAINLESS STEEL. 5.WHERE NOTED IN THE TABLE, APPLICATIONS WHERE THE WOOD IS DRY (MOISTURE CONTENT LESS THAN 19%) WHEN INSTALLED AND WILL REMAIN DRY IN-SERVICE MAY USE MINIMUM COATING RECOMMENDATION OF "LOW". 6.TYPE 316 STAINLESS-STEEL CONNECTORS AND FASTENERS ARE THE MINIMUM RECOMMENDATION FOR OCEAN-SALT AIR AND OTHER CHLORIDE ENVIRONMENTS. ALL HANGERS/FASTENERS IN CONTACT WITH PRESERVATIVE TREATED WOOD BUT WITH VYCOR DECK PROTECTOR BARRIER MEMBRANE (NOTE: THIS IS CONTRACTORS OPTION) INSTALLED BETWEEN THE CONNECTOR AND TREATED WOOD MAY USE TABLE 2. 'CONNECTOR COATING RECOMMENDATION WHEN USING A BARRIER MEMBRANE -STRUCTURAL APPLICATIONS.' BELOW TO SELECT REQUIRED COATING. LOW = USE STANDARD PAINTED AND G90 GALVANIZED CONNECTORS, OR SIMPSON STRONG-TIE STRONG DRIVE SCREWS (SDS) WITH THE DOUBLE-BARRIER COATING, AS A MINIMUM MED = USE ZMAX/HDG GALVANIZED CONNECTORS AS A MINIMUM. USE HDG FASTENERS WHICH MEET THE SPECIFICATIONS OF ASTM A153 OR SIMPSON STRONG-TIE STRONG DRIVE SCREWS (SDS) WITH DOUBLE-BARRIER COATING. HIGH '6' = USE TYPE 303, 304, 305 OR 316 STAINLESS-STEEL CONNECTORS AND FASTENERS. TABLE 2: CONNECTOR COATING RECOMMENDATION WHEN USING A BARRIER MEMBRANE - STRUCTURAL APPLICATIONS ENVIRONMENT UNTREATED WOOD MCQ ACQ-C, ACQ-D (CARBONATE). CA-B, CA-C & CBA-A NO AMMONIA WITH AMMONIA HIGHER CHEMICAL CONTENT1 ACZA OTHER OR UNCERTAIN INTERIOR -DRY NOT NEEDED LOW LOW HIGH HIGH HIGH HIGH EXTERIOR -DRY N/A2 HIGH HIGH HIGH HIGH EXTERIOR -WET HIGH HIGH HIGH HIGH EXPOSURE HIGH HIGH HIGH HIGH UNCERTAIN HIGH HIGH HIGH HIGH N/A2 N/A2 N/A2 HIGH HIGH HIGH MED2,4 MED2,4 HIGH HIGH MED2,4 MED2,4 1.WOODS WITH ACTUAL RETENTION LEVELS GREATER THAN 0.40 PCF FOR ACQ AND MCQ, 0.41 PCF FOR CBA-A, OR 0.21 PCF FOR CA-B (GROUND CONTACT LEVEL). 2.BORATE TREATED WOODS ARE NOT APPROPRIATE FOR OUT DOOR USE. 3.TEST RESULTS INDACTE THAT ZMAX/HDG AND SDS DOUBLE-BARRIER COATING WILL PERFORM ADEQUATELY, SUBJECT TO REGULAR MAINTENANCE AND PERIODIC INSPECTION. HOWEVER, THE NATIONALLY-APPROVED TEST METHOD USED, AWPA E12-94IS AN ACCELERATED TEST, SO DATA OVER AN EXTENDED PERIOD OF TIME IS NOT AVAILABLE. IF UNCERTAIN, USE STAINLESS STEEL. 4.SOME TREATED WOOD MAY HAVE EXCESS SURFACE CHEMICALS MAKING IT POTENTIALLY MORE CORROSIVE. IF YOU SUSPECT THIS OR ARE UNCERTAIN, USE STAINLESS STEEL. 5.ZINC BORATE IS A PERSERVATIVE TREATMENT FOR WOOD COMPOSITES. 6.SBX/DOT SODIUM BORATE AND ZINC BORATE ARE LESS CORROSIVE THAN CCA-C. THERE USING G90 GALVANIZED CONNECTORS WITHOUT A BARRIER IS APPROPRIATE. 7.TYPE 316 STAINLESS-STEEL CONNECTORS ARE THE MINIMUM RECOMMENDATION FOR OCEAN-SALT AIR AND OTHER CHLORIDE ENVIRONMENTS. IF THE PRESERVATIVE USED TO TREAT THE WOOD IS NOT LISTED IN THE TABLE ABOVE, CONTRACTOR SHALL USE STAINLESS STEEL HANGERS/FASTENERS OR SUBMIT SPECIFICATIONS TO ARCHITECT/ENGINEER FOR FURTHER REVIEW. LATERAL BASIC WIND SPEED (3 SECOND GUST)=120 MPH (ULT) EXPOSURE CATEGORY = C SEISMIC LOADING (E.L.F. PROCEDURE) SEISMIC DESIGN CATEGORY, SDC = D IMPORTANCE FACTOR, I = 1.0 SITE CLASS = D MAPPED SPECTRAL RESPONSE ACCEL., S1 = 0.18g DESIGN SPECTRAL RESPONSE ACCEL., SD1 = 0.48g;SDS = 0.66g RESPONSE MODIFICATION FACTOR, R = 6.5 (TYPE A.15) BACKFILL 1.DO NOT COMPLETE BACKFILL AGAINST FOUNDATIONS UNTIL FLOOR FRAMING IS IN PLACE 2.DO NOT BACKFILL AGAINST FOUNDATIONS UNTIL MOISTURE BARRIER HAS BEEN APPLIED AND INSPECTED 3.DO NOT BACKFILL AGAINST FOUNDATIONS UNTIL CONCRETE HAS CURED FOR 28 DAYS WITHOUT PRIOR APPROVAL FROM E.O.R. 4.ALL BACKFILL SHALL BE FREE FROM DEBRIS AND SHALL NOT DAMAGE THE MOISTURE BARRIER 5.BACKFILL SHALL NOT CONTAIN ROCKS OR DEBRIS LARGER THAN 2" IN DIAMETER 6.ALL SITE FILL AND BACKFILL SHALL BE PLACED IN 8" LIFTS AND COMPACTED TO 90% OF MAXIMUM DENSITY AFTER EACH LAYER INSPECTIONS (I.R.C.) INSPECTIONS SHALL BE PERFORMED BY AN APPROVED ENTITY RETAINED BY THE OWNER AND SHALL BE PERFORMED AS REQUIRED BY I.R.C. SECTION R109 OR AS OTHERWISE DICTATED BY THE BUILDING OFFICIAL DURING CONSTRUCTION OF THE FOLLOWING TYPES OF WORK: 1.FOUNDATION INSPECTION: A.INSPECTION OF THE FOUNDATION SHALL BE MADE AFTER POLES OR PIERS ARE SET OR TRENCHES OR BASEMENT AREAS ARE EXCAVATED AND ANY REQUIRED FORMS ERECTED AND ANY REQUIRED REINFORCING STEEL IS IN PLACE AND SUPPORTED PRIOR TO THE PLACING OF CONCRETE. THE FOUNDATION INSPECTION SHALL INCLUDE EXCAVATIONS FOR THICKENED SLABS INTENDED FOR THE SUPPORT OF BEARING WALLS, PARTITIONS, STRUCTURAL SUPPORTS, OR EQUIPMENT AND SPECIAL REQUIREMENTS FOR WOOD FOUNDATIONS. 2.FRAMING AND MASONRY INSPECTION: A.INSPECTION OF FRAMING AND MASONRY CONSTRUCTION SHALL BE MADE AFTER THE ROOF, MASONRY, FRAMING, FIRESTOPPING, DRAFTSTOPPING AND BRACING ARE IN PLACE AND AFTER THE PLUMBING, MECHANICAL AND ELECTRICAL ROUGH INSPECTIONS ARE APPROVED. 3.FINAL INSPECTION: A.FINAL INSPECTION SHALL BE MADE AFTER THE PERMITTED WORK IS COMPLETE AND PRIOR TO OCCUPANCY. ISSUE DATE:910 Brooks Street, Suite 203Missoula, MT 59801406.542.2849www.aeg.designPROJECT NO:2/7/2024 3:40:55 PMIssue Date S0.1 GENERAL NOTES305 SOUTH 5th STREETBOZEMAN, MT. 59715NEW GARAGE / ADUPERMIT SET23-040 SHEET INDEX REV # SHEET NO.TITLE S0.1 GENERAL NOTES S0.2 MEMBER SCHEDULES S0.3 TYP. DETAILS S0.4 TYP. DETAILS S0.5 FRAMING SCHEDULES S2.0 STRUCTURAL PLAN S4.0 STRUCTURAL SECTIONS S4.1 STRUCTURAL SECTIONS REVISIONS DATE DESCRIPTION