HomeMy WebLinkAboutnorth south elevationsELEV. 100'-0"
T.O. SLAB
ELEV. 99'-10"
T.O. GRADE
ELEV. 123'-8"
T.O. RIDGE
ELEV. 109'-7"
T.O. 2ND LVL. SUBFLOOR
ELEV. 115'-7"
T.O. PLATE
8
12
4
12
ELEV. 122'-7"
T.O. DORMER RIDGE
ELEV. 124'-0"
T.O. RIDGE (HOUSE)
ASPHALT SHINGLES OVER
ROOFING MEMBRANE OVER
3/4" PLYWOOD OVER
2X10 WOOD RAFTERS OVER
5/8" GYP BOARD
FASCIA / SOFFIT / RAKE TO MATCH
EXISTING HOUSE DETAIL
LAP SIDING TO MATCH EXISTING HOME OVER
5/8" PLYWOOD OVER
2X6 WOOD FRAMING OVER
BATT INSULATION OVER
5/8" GYP BOARD
4" CONCRETE SLAB ON GRADE FOUNDATION
W/ THICKENED EDGE OVER
4" GRAVEL (REF. STRUCTURAL)
VELUX SKYLIGHT
(MODEL FS C04 2004)
ALUMINUM CLAD WOOD WINDOW
OPERABLE STEEL
FURNITURE LIFT (SEE DET. XXX)
GABLE TO MATCH DORMER ENDS
ON EXISTING HOUSE DETAIL
DARK SKY COMPLIANT EXT. FIXTURE (TYP.)
A
102
CCC
D
4
12
ELEV. 100'-0"
T.O. SLAB
ELEV. 99'-10"
T.O. GRADE
ELEV. 123'-8"
T.O. RIDGE
ELEV. 109'-7"
T.O. 2ND LVL. SUBFLOOR
ELEV. 115'-7"
T.O. PLATE
8
12
ELEV. 122'-7"
T.O. DORMER RIDGE
ELEV. 124'-0"
T.O. RIDGE (HOUSE)
4
12
ASPHALT SHINGLES OVER
ROOFING MEMBRANE OVER
3/4" PLYWOOD OVER
2X10 WOOD RAFTERS OVER
5/8" GYP BOARD
FASCIA / SOFFIT / RAKE TO MATCH
EXISTING HOUSE DETAIL
LAP SIDING TO MATCH EXISTING HOME OVER
5/8" PLYWOOD OVER
2X6 WOOD FRAMING OVER
BATT INSULATION OVER
5/8" GYP BOARD
4" CONCRETE SLAB ON GRADE FOUNDATION
W/ THICKENED EDGE OVER
4" GRAVEL (REF. STRUCTURAL)
VELUX SKYLIGHT
(MODEL FS C06 2004)
ALUMINUM CLAD WOOD WINDOW
GABLE TO MATCH DORMER ENDS
ON EXISTING HOUSE DETAIL
OPERABLE STEEL
FURNITURE LIFT (SEE DET. XXX)
DARK SKY COMPLIANT EXT. FIXTURE (TYP.)
C
E
A A
ISSUE DATE:
Scale: 1/4" = 1'-0"
GARAGE NORTH ELEVATION1
A 3.02
EXTERIOR ELEV.
www.orlandopiva.com
406.580.3981
Scale: 1/4" = 1'-0"
GARAGE SOUTH ELEVATION2
XX/XX/XX1
305 SOUTH 5TH STREETBOZEMAN, MT. 59715Project: 305 S. 5TH
REMODELNEW GARAGE / ADU