Loading...
HomeMy WebLinkAboutZMA Tech Memo-Combined 1 | P a g e Technical Memorandum Date: 3/7/2024 Project: 24024 1920 W Babcock ZMA RE: Response to Plan Review – Review Comments Report (Engineering) 3/4/2024 Narrative: The following memo is to address comments provided by Suzanne Ryan (City of Bozeman Engineering) on 2/6/2024. The subject ZMA is to change the existing zoning from Residential Office (R-O) to Community Business District-Mixed (B-2M). The legal description of the ZMA is: A portion of land being Lot 10, Block 1 of the Kirk Subdivision (Plat F-1), and the adjoining 30 feet of Right-of-Way for West Babcock Street and South 20th Ave., located in Sec. 11, T. 2 S., R. 5 E., City of Bozeman, Gallatin County, Montana, containing 18,322 square feet or 0.421 acres. Lot 10, Block 1 of the Kirk Subdivision (Plat F-1) which is the parcel that will actually be re- developed contains 10,843 square feet or 0.248 acres. The subject ZMA area was previously used as an Allstate Insurance Agency. The business was in a structure that was originally a single-family home that was converted to commercial use. The previous structure has since been demolished and Lot 10 is vacant. The number of employees and customers that occupied the demolished insurance agency building is unknown and the insurance agent has since passed away. The proposed building to be constructed on Lot 10 is a 5-plex residential structure that will have (3) 2- bedroom units and (2) 3-bedroom units. The estimated population of the building is (5 units x 2.11 people/unit) 10.55 people. Being the previous building has been demolished and the employee and customer occupancy is unknown these calculations use the original single-family occupancy of the building in comparing existing and proposed zoning water, wastewater and traffic demands. Water Demand: Proposed Zoning (B2-M) Fire-Flow -- The building construction type for the proposed 5-plex residential structure is Type V-B, building area is 6,580 sq-ft. The structure will be equipped with an automatic fire sprinkler system. Based on Table B105.1, Appendix B, IFC, the required fire-flow is 2,250 gpm for 2 hours. Being the building is equipped with an automated fire sprinkler system, the fire-flow is reduced to 1,500 gpm for 2 hours. Domestic / Irrigation Use -- (Based Section V. of the COB Design Standards) Average Daily Usage = 10.55 People x 170 gpd/person = 1,793.50 gpd Maximum Day = Average Day x 2.3 = 4,125.00 gpd 2 | P a g e Max Hour = (Average Day x 3.0)/24 = 224.2 gph Peak Instantaneous = 19 GPM (see attached AWWA M22) Existing Zoning (R-O) Fire-Flow – Being the previous building on the site has been demolished and was originally a single-family home we assume s fire-flow of 1,500 gpm for 2 hours. Domestic / Irrigation Use (Based Section V. of the COB Design Standards) assumes the previous now demolished structure had a water use equivalent to one single family home which was the original use of the structure. Average Daily Usage = 2.11 People x 170 gpd/person = 358.70 gpd Maximum Day = Average Day x 2.3 = 825.00 Max Hour = (Average Day x 3.0)/24 = 44.84 gph Peak Instantaneous = 24 GPM (see attached AWWA M22) Comparison Existing (R-O) to Proposed Zoning (B2-M) Peak Instantaneous + Fire Flow Existing (R-O) = 1519 Proposed (B2-M) = 1524 Peak Hour Water Demand Existing (R-O) = 45 gpd Proposed (B2-M) = 224 gpd Wastewater Demand: Proposed Zoning (B2-M) – Based on 5 dwelling units Wastewater Flow -- (Based Section B. of the COB Design Standards) Average Daily Usage = 10.55 People x 89 gpd/person = 939 gpd Infiltration = 0.421 ac. x 150 gallons/ac./day = 63 gpd Total Average Daily Usage = 1,002 gpd Maximum Day = Average Day x 2.3 = 2,305 gpd Max Hour = (Average Day x 3.0)/24 = 3,006 gph Existing Zoning (R-O) – Based on 1 dwelling units Wastewater Flow -- (Based Section B. of the COB Design Standards) Average Daily Usage = 2.11 People x 89 gpd/person = 188 gpd 3 | P a g e Infiltration = 0.421 ac. x 150 gallons/ac./day = 63 gpd Total Average Daily Usage = 251 gpd Maximum Day = Average Day x 2.3 = 577 gpd Max Hour = (Average Day x 3.0)/24 = 753 gph Traffic: Proposed Zoning (B2-M) – Based on ITE Code 220 and 5 dwelling units Average Daily Trips = 34 Trips Peak AM (7-9) = 2 Trips Peak PM (4-6) = 3 Trips Existing Zoning (R-O) – Based on 1 dwelling units Average Daily Trips = 9.4 Trips Peak AM (7-9) = 1 Trips Peak PM (4-6) = 1 Trips Prepared by Clint Litle, PE Facility Name Building address or number Residential or Non-Residential Minimum Pressure (psi) Fixture Value Number of Subtotal Fixture or Appliance (at 60 psi)Fixtures Fixture Value Toilet (Flushometer Tank) 1.3 2 2.6 Toilet (flush valve)0 0 Urinal (Flushometer Valve) 2 0 0 Urinal (flush valve)0 0 Bidet 0 0 Shower (single head)2 2 4 Sink (lavatory)1 2 2 Kitchen Sink 1.5 1 1.5 Utility Sink 1.5 1 1.5 Dishwasher 1.5 1 1.5 Bathtub 0 0 Clothes Washer 6 1 6 Hose connections (with 50 ft of hose) 1/2 in. 2.5 2 5 5/8 in. 9 0 0 3/4 in. 12 0 0 Miscellaneous Bedpan washers 10 0 Drinking fountains 2 0 0 Dental units 2 0 Combined Fixture Value 24.1 Demand (gpm)19 Pressure Adjustment Factor 1 Total Adjusted demand (gpm)19 Water Demand Estimate Using Fixture Values (Based on AWWA M22 Manual, Second Edition) Ex. RO Zoning - 1920 W. Babcock ZMA Note: Fixture count based on City of Bozeman Water Service Calculation Worksheet - Commercial (2018 IBC), UPC Table 610.3 Standard Design Water Supply Fixture Units Facility Name Building address or number Residential or Non-Residential Minimum Pressure (psi) Fixture Value Number of Subtotal Fixture or Appliance (at 60 psi)Fixtures Fixture Value Toilet (Flushometer Tank) 1.3 10 13 Toilet (flush valve)0 0 Urinal (Flushometer Valve) 2 0 0 Urinal (flush valve)0 0 Bidet 0 0 Shower (single head)2 10 20 Sink (lavatory)1 10 10 Kitchen Sink 1.5 5 7.5 Utility Sink 1.5 5 7.5 Dishwasher 1.5 5 7.5 Bathtub 0 0 Clothes Washer 6 5 30 Hose connections (with 50 ft of hose) 1/2 in. 2.5 4 10 5/8 in. 9 0 0 3/4 in. 12 0 0 Miscellaneous Bedpan washers 10 0 Drinking fountains 2 0 0 Dental units 2 0 Combined Fixture Value 105.5 Demand (gpm)24 Pressure Adjustment Factor 1 Total Adjusted demand (gpm)24 Water Demand Estimate Using Fixture Values (Based on AWWA M22 Manual, Second Edition) Proposed B-2M Zoning - 1920 W. Babcock ZMA Note: Fixture count based on City of Bozeman Water Service Calculation Worksheet - Commercial (2018 IBC), UPC Table 610.3 Standard Design Water Supply Fixture Units