HomeMy WebLinkAbout030 - ES101 - ELECTRICAL SITE PLANMGENERAL NOTESA. COMPLY WITH LATEST ADOPTED NEC AND APPLICABLE CODES/STANDARDS.B. SHARED NEUTRALS ARE NOT ALLOWED FOR SINGLE PHASE BRANCH CIRCUITS.METER STACK 'A1' METER STACK 'A2' METER STACK 'B1' METER STACK 'B2'EXISTING UTILITY POWER POLEEXISTING UTILITY POWER POLEEXISTING UTILITY POWER POLEEXISTING UTILITY POWER POLEPROPOSED RELOCATED UTILITY POWER POLEPROPOSED RELOCATED UTILITY POWER POLEUTILITYXFMRPROPOSED RELOCATED UTILITY POWER POLEPROPOSED STREET LIGHT LOCATION MSB-CMSB292111UNITS IN THIS AREA ROUTE TO METER STACK A1UNITS IN THIS AREA ROUTE TO METER STACK A2UNITS IN THIS AREA ROUTE TO METER STACK B1UNITS IN THIS AREA ROUTE TO METER STACK B2PROPOSED STREET LIGHTING TRANSFORMER WITH SERVICE PEDESTAL/METERN. EIGHTH AVENUEASPEN STREET 111111111222222WP1EWP1EWP2+22' ABVGRADE(TYP)WP2WP2WP2WP2WRWREWREWRWRWRWR WR WRE WRE WR WREWP1EWP2E+15'AFF+8'6"AFF+8'-6"AFFWREWRWRWREWROCOCWPWPWPWPWPWP2WPWPWPWPWP2WP1+8'6"AFFGAS SERVICEENTRANCE+15'AFFOVERHEAD ELECTRICAL TERM PULL BOXLOCATION OF HOUSE PANELS ABOVELOW VOLTAGE DMARK LOCATIONMDFELEC & COMM ROOMCOMMERCIALSHELL117COMMERCIALSHELL116COMMERCIALSTORAGE122BIKE STORAGE /REPAIR107TENANT STORAGE106PET WASH112MAIL ROOM105VESTIBULE100ELEVATOR LOBBY101RESTROOM119RESTROOM118ENTRY VESTIBULE110NORTH ELEVATOREL2-1FIRE RISER115TRASHPROCESSING114RAMP109SKI STORAGE /TUNING108SOUTH ELEVATOREL1-1STAIR 2ST2-1SHARED OUTDOORSPACEOOS-NESHARED OUTDOORSPACEOOS-WMSB1P1BP1TENANT COLLAB120OFFICE102RESTROOM103PARCEL ROOM104BIKE STORAGE /REPAIR107VESTIBULE1203DFF4(TYP.)______________ES10121PROPOSED UTILITY POWER POLE BY NWEPROPOSED UTILITY PULL BOX BY NWEWP1EWP1111#KEYNOTES1. SCOPE OF WORK PROVIDED WITH INFRASTRUCTURE PLANS. SHOWN ON THESE DRAWINGS FOR REFERENCE ONLY.2. VEHICLE CHARGING STATION. UTILIZED CHARGEPOINT CT4000 SERIES, DUAL HEAD, STANDARD POWER SHARE, BOLLARD MOUNTED CHARGING STATION FOR BASIS OF DESIGN. CHARGING STATION TO BE SUPPLIED BY OTHERS, INSTALLED BY EC. EC TO CONFIRM CHARGING STATION TO BE UTILIZED PRIOR TO ROUGH IN. CONFIRM 208V POWER SHARE CONNECTION IS AVAILABLE NOTE, AN ADDITIONAL 1" CONDUIT MAY BE REQUIRED IF DEVICE REQUIRES LOW VOLTAGE COMMUNICATIONS WIRING.3. PROVIDE (1) 2" CONDUIT FROM MDF LOCATION TO 5' OUTSIDE OF BUILDING FOOTPRINT FOR SPECTRUM FIBER. SEE CIVIL PLANS FOR FURTHER REQUIREMENTS. 4. UNIT FEEDER CONDUCTORS TO ROUTE FROM BACK OF METER, INSIDE OF WALL CAVITY, TO SECOND FLOOR CEILING SPACE. EXTERIOR CONDUITS ON FACE OF BUILDING NOT ALLOWED, WITH THE EXCEPTION OF CONDUITS HEADED UNDERGROUND. TRASHPROCESSING114REVISIONS3/28/2024 9:15:52 PMELECTRICAL SITEPLANES101 | Project# 8ASPEN_MFCD | L:\8ASPEN_MFCD\BIMCAD\Revit03/01/2024© 2024 | ALL RIGHTS RESERVEDDESIGNDEVELOPMENT8TH AND ASPENMIDTOWN 8TH LLCMIXED-USE BUILDINGPROJ# | 8ASPEN_MFCDDESIGNED BY | SCHRENKDRAWN BY | KAUFMANREVIEWED BY | MAEHL1" = 20'-0"ES1011ELECTRICAL SITE PLANNOTES:1) PROVIDE TRANSFORMER AND MOUNTING HARDWARE AS REQUIRED FOR COMPLETE SYSTEM.9) ONBOARD MOTION DETECTION AND AUTO DIM TO MEET IECC REQUIREMENTS.10) PROVIDE SHADE-HT-BK-BK-8 AND REQUIRED ACCESSORIES TO ELIMINATE UP-LIGHT.LIGHTING FIXTURE SCHEDULETYPEFIXTURELIGHT SOURCE OPTIONSNOTESDESCRIPTION MANUFACTURERCATALOG NUMBERMOUNTINGVOLTAGE VALAMPTYPENUMBEROF LAMPSLUMENS EMERGENCYLOCATION TYPE HEIGHTA3 LED DISK LIGHT - 1400 LUMEN PORTER LIGHTING PTDLSM R121 22W 3CCT CEILING CEILING MOUNTED - 120 V 22.00 LED 1400 lm NOTE 11,12HR HANDRAIL LIGHTING KILK LP SQ 27K A 12 HANDRAIL RECESSED - 120 V 2.00 LAMP TYPE 1 145 lm NOTE 13OC EXTERIOR CATENARY STRING LIGHT TIVOLI LSL B 12 S 19 C 12 CEILING SUSPENDED 120 V 12.0040 lm NOTE 1,10WP1 EXTERIOR WALL PACK GARDCO GWM-A06-830-T4M-UNV-PCB-BK- MW30-CS50 WALL SURFACE SEE PLAN 120 V 16.00 LED <varies> NOTE 9WP1E EXTERIOR WALL PACK EM GARDCO GWM-A06-830-T4M-UNV-PCB-EM-BK WALL SURFACE SEE PLAN 120 V 16.00 LED <varies> XWP2 EXTERIOR PARKING LOT FLOOD GARDCO GWM-A08-830-T4M-120-PCB-BK-MW30-CS50 WALL SURFACE SEE PLAN 120 V 30.00 LED 4440 lm NOTE 9WP2E EXTERIOR WALL PACK EM LUMARK GWM-A08-830-T4M-120-PCB-BK-EM WALL SURFACE SEE PLAN 120 V 30.00 LED 4440 lm XWR EXTERIOR RECESSED LINEAR DIRECTWET LOCATIONPAL ML3WL66D MO K30 80 4 (x) LOH F10 (xx) 120 CWD CANOPY RECESSED 120 V 17.001713 lmWRE EXTERIOR RECESSED LINEAR DIRECTWET LOCATION EMPAL ML3WL66D MO K30 80 4 (x) LOH F10 (xx) 120 CWDEBPHSTCANOPY RECESSED 120 V 17.001713 lm XWS1 EXTERIOR BALCONY STEP LIGHT LUMASCAPE LS1260 08 D 827 F SQ MD 090 PA XXX, LS6332 WALL SURFACE 0'18"AFF 120 V 8.00 LED 600 lm NOTE 12NORTH REF1/8" = 1'-0"ES1012TRASH PROCESSING SNOW MELT ENLARGED VIEW111 03.27.2024 SITE PLAN 0111