Loading...
HomeMy WebLinkAbout042 - Electric Site Photometric PlanWDWDWDSP2SP2LC1LC1SP1SP2SP2SP1SP2SP2SP2SP2SP2SP2SP2SP2SP2SP2SP2SP2SP1SP1SP1LC1LC1LC1LC1LC124"BELOW30"P124"MIN.3"3"34105678169216121411157"Z""Y""X"TYPEPOLEPOLE BASE DIMENSIONS"X""Y""Z"PLAN VIEWFINISHEDPAVEMENTOR GRADEKEYED NOTES:HANDHOLECHAMFEREDGESPOLESECTION VIEW13#6 AWG114POLE HEIGHT"Y" VALUE< 13'-0"4'-0"13'-0" - 20'-0"21'-0" - 30'-031'-0" - 40'-0"5'-0"6'-0"8'-0"MINIMAL SLOPE FOR DRAINAGE1. PROVIDE 1" MINIMUM SCHEDULE 40 ELECTRICAL PVC CONDUIT. BACKFILL WITH EXCAVATED OR BORROWED MATERIAL. MATERIAL SHALL BE FREE OF ROCKS 1" DIAMETER AND LARGER. COMPACT TO 90% IN MAX 8" LIFTS OF LOOSE SOIL.2. PROVIDE 3000# CONCRETE BASE (CLASS A FORMED SURFACE WHERE EXPOSED).3. GROUND LUG IN BASE BOLTED TO BASE PLATE WITH MIN. #6 AWG SOLID COPPER CONDUCTOR.4. BASE COVER OVER GALVANIZED STEEL WASHERS, NUTS & LOCKNUTS.5. GROUND CLAMP, IRREVERSIBLE SPLICE.6. 1/2" SCHEDULE 40 ELECTRICAL PVC FOR GROUND WIRE.7. PROVIDE MINIMUM OF FOUR ANCHOR BOLTS, GALVANIZED STEEL.8. PROVIDE #4 TIE LOOPS AT 3" FROM TOP AND BOTTOM AND +/- 12" C/C BETWEEN LOOPS.9. (6) #6 VERTICAL REBARS - TIE VERTICAL BARS TO TIE LOOPS.10. FOR BASES FLUSH WITH PAVEMENT, DO NOT PROVIDE CHAMFER. SEAL THE PERIMETER OF THE BASE TOP INSTEAD.11. PROVIDE 24" MINIMUM RADIUS; EXTEND 3/4" MAXIMUM ABOVE FOUNDATION WITH NUMBER OF CONDUITS AS NEEDED, 1" MIN.12. PROVIDE DIAMETER BOLT CIRCLE PER LUMINAIRE MANUFACTURER.13. "X" AND "Y" DIMENSIONS ARE MINIMUM LENGTHS FROM THIS LINE. WHERE GRADE OR PAVEMENT IS SLOPED, "Y" IS FROM THE LOW SIDE OF THE SLOPE AND "X" IS FROM THE HIGH SIDE OF THE SLOPE.14. PROVIDE ROUND CONCRETE BASE.15. PROVIDE REBAR CAGE.16. PROVIDE 5/8" X 10' GROUND ROD.GENERAL PHOTOMETRIC PLAN NOTESA. PHOTOMETRIC REPORT: THIS PHOTOMETRIC REPORT REPRESENTS ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA (IES FILES). THIS LABORATORY DATA IS TAKEN UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH THE ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED METHODS. ACTUAL PERFORMANCE OF ANY MANUFACTURER'S LUMINAIRES MAY VARY SOMEWHAT DUE TO VARIATION IN ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS, AND OTHER VARIABLE FIELD CONDITIONS.B. ILLUMINATION LEVELS: THE ILLUMINATION LEVELS SHOWN, MEASURED IN FOOTCANDLES, ARE BASED ON THE SPECIFIED CRITERIA. ANY SUBSTITUTIONS/DEVIATIONS IN LUMINAIRES OR MOUNTING HEIGHTS, OR ALTERATIONS TO THE LAYOUT, WILL AFFECT ILLUMINATION LEVELS SHOWN AND WILL NOT BE THE RESPONSIBILITY OF KLH ENGINEERS.C. ADJUSTMENTS: PROVIDE FINAL ADJUSTMENTS TO AIMING ANGLE(S) OF LUMINAIRES IF OR AS REQUIRED TO ELIMINATE LIGHT TRESPASS OR GLARE ONTO ADJACENT PROPERTIES AND/OR ROADWAYS.D. LUMINAIRE SCHEDULE: REFER TO LUMINAIRE SCHEDULE FOR LUMINAIRE AND POLE INFORMATION. THE LUMINAIRE SCHEDULE INCLUDED ON THIS SHEET IS FOR PHOTOMETRIC REVIEW REFERENCE ONLY.E. ADJACENT CONTRIBUTIONS: CONTRIBUTIONS FROM ADJACENT STREET LIGHTING, ADJACENT PROPERTIES, AND BUILDING OR POLE MOUNTED LUMINAIRES NOT WITHIN THIS PROJECT SCOPE ARE NOT REFLECTED IN THIS PHOTOMETRIC REPORT.F. CRITERIA: FOOTCANDLE LEVELS SHOWN ARE MAINTAINED AND CALCULATED AT GRADE BASED ON SPECIFIED MOUNTING HEIGHT FOR POLE-MOUNTED FIXTURES.DRAWN BY:PROJ. NO:ADDRESS:SHEET SIZE:30" x 42"#DATEDESCRIPTIONSHEET TITLE & NUMBERCHECKED BY:PROJECT INFORMATIONCopyright 2021 PROJECT REVISIONSISSUED:REVISED:SEALARCHITECTCLIENTCONSULTANTSTRUCTURALM.E.P.PROJECTCIVILA11BCDEFGHJ234567891011234567891011ABCDEFGHJ12128/23/2023 10:20:11 AME103ELECTRIC SITEPHOTOMETRIC PLANJJL95275Valley Center RD,Bozeman, MT 5971503/21/23TIDAL WAVETHORSON BAKER + ASSOCIATES2055 READING ROAD, SUITE 280CINCINNATI, OH 45202513.579.8200KLH ENGINEERS1538 ALEXANDRIA PIKE STE 11FORT THOMAS, KY 41075614.603.2662TIDAL WAVE AUTO SPAValley Center RD,Bozeman, MT 59715NEW POTATO CREEK HOLDINGS, LLC124 E. THOMPSON STREETTOMASTON, GA 30286REZTARK DESIGN STUDIO, LLC601 MAIN STREET, SUITE 200CINCINNATI, OH 45202513.233.3333REZTARK DESIGN STUDIO, LLC(UNDER SEPARATE OWNER CONTRACT)MADISON ENGINEERINGBOZEMAN, MT 59718460.586.0262LGFAUTO SPA1/16" = 1'-0"1ELECTRIC SITE PHOTOMETRIC PLANSCALE: NONE265100.00-08 - LIGHT POLE BASE DETAIL - ROUNDGENERAL NOTES:A. REFER TO DRAWINGS FOR MOUNTING TYPE, NUMBER OF FACES AND ARROWS OF EXIT SIGNS. VERIFY IN FIELD PRIOR TO INSTALLATION.B. VERIFY COMPATIBILITY WITH VOLTAGE, CONTROLS, ETC. FOR ALL LUMINAIRE COMPONENTSC. COORDINATE EACH LUMINAIRE LOCATION WITH THE ARCHITECTURAL REFLECTED CEILING PLANS, CEILING INSTALLERS, ETC. AND PROVIDE APPROPRIATE MOUNTING SYSTEM REQUIRED FOR EACHLUMINAIRE. ALSO, PROVIDE PLASTER FRAMES, WALL BRACKETS, SUPPORTS, OR OTHER APPURTENANCES AS REQUIRED FOR PROPER AND COMPLETE INSTALLATIONS.D. WEAR CLEAN WHITE COTTON GLOVES WHEN HANDLING EXPOSED REFLECTIVE LUMINAIRE SURFACES. REMOVE PLASTIC SHIPPING BAGS ONLY AFTER INTERIOR WORK IS COMPLETE, AND CLEAN ALLSURFACES WITH CLEAN DRY CHEESECLOTH.E. MOUNTING HEIGHTS INDICATED ARE TO THE BOTTOM OF THE LUMINAIRE, UNLESS OTHERWISE NOTED.F. PRODUCTS: PROVIDE PRODUCTS INDICATED ON DRAWINGS AND SCHEDULES. WHERE MULTIPLE MANUFACTURER SERIES/MODEL NUMBERS ARE LISTED FOR A SINGLE LUMINAIRE, PROVIDE ONE OFTHOSE LISTED. WHERE A SPECIFIC MANUFACTURER SERIES/MODEL NUMBER IS LISTED AS BASIS-OF-DESIGN, AND WHERE IT IS STATED THAT EQUIVALENTS WILL BE CONSIDERED, ANY PROPOSEDNON-LISTED LUMINAIRES ARE SUBJECT TO REVIEW BY DESIGN PROFESSIONAL(S), SUBMITTALS FOR WHICH SHALL BE FURNISHED AT LEAST (10) DAYS PRIOR TO BID DUE DATE OR THEY WILL NOT BECONSIDERED. THESE PRE-BID SUBMITTALS SHALL CLEARLY STATE EXACTLY WHAT IS BEING PROPOSED AND SHALL DEMONSTRATE COMPLIANT EQUIVALENCY. SIMILAR REQUESTS FOR PROPOSEDSUBSTITUTIONS MAY BE MADE ONLY AFTER BIDS ARE RECEIVED, AND ONLY IF OWNER CHOOSES TO CONSIDER SUBSTITUTION REQUESTS. DESIGN PROFESSIONAL(S) AND OWNER RESERVE THE RIGHTTO REJECT ALL PRODUCTS THAT ARE NOT DEEMED TO BE FULLY EQUIVALENT TO THE BASIS-OF-DESIGN LISTING(S). SUBMIT ALL REQUESTS AND QUESTIONS THROUGH THE FORMALLY-ESTABLISHEDBIDDING PROCESS, NOT DIRECTLY TO ENGINEER.EXTERIOR LUMINAIRE SCHEDULETYPE DESCRIPTION MANUFACTURER / SERIES HOUSING / MOUNTING MATERIALLAMPQTYLAMP TYPE COMMENTS FIXTURE LOAD VOLTAGEP1 AREA LIGHTINGPOLETBD - POLE AND FINISH TOBE SELECTED BY ARCHITECTBASEWET LISTED 0 VA 0 VSP1 AREA LIGHTINGLUMINAIREU.S. ARCHITECTURALLIGHTINGRZR-M-PLED-IV-FT-24LED-525MA-CW-HSPOLE CAST BLACKPAINTED FINNEDMETAL HOUSING1 LED 4000K WET LISTED 42 VA 277 VSP2 AREA LIGHTINGLUMINAIREU.S. ARCHITECTURALLIGHTINGRZR-M-PLED-II-24LED-350MA-CW-HSPOLE CAST BLACKPAINTED FINNEDMETAL HOUSING1 LED 4000K WET LISTED 28 VA 277 VWD LED WEDGE WALLMOUNT LIGHTLITHONIA WDG2 LED P2 40K70CRI TFTM E10WHSURFACE WALL - MOUNT AT11' AFFALUMINUM 1 LED, 4000K, 70CRIWET LISTED, INTEGRAL PHOTOCELL,PROVIDE 90 MIN BATTERY BACK UP.23 VA 277 VALL FIELDS LEFT BLANK IN THE SCHEDULE BELOW ARE TBD BY POLE MANUFACTURER. MANUFACTURER IS RESPONSIBLE FOR PERFORMING CALCULATIONS AND FURNISHING A POLE THAT MEETS EPA REQUIREMENTS FOR THE PROJECTLOCATION AND THE SELECTED POLE MOUNTED LUMINAIRES. REFER TO SITE LIGHTING PLAN FOR OTHER ITEMS THAT MAY BE INSTALLED ON POLE, SUCH AS SECURITY EQUIPMENT, AND ACCOUNT FOR THIS IN THE CALCULATIONS.ELECTRIC LUMINAIRE POLE SCHEDULETYPE DESCRIPTION MANUFACTURER / SERIES MATERIAL SIZE GAUGE HEIGHT EPA MOUNTING ACCESSORIES FINISH COMMENTSP1 POLE TBD17' - 6" MINIMUM 0.5 POLE BASEILLUMINANCE RESULTSCalculation Points Name Average Maximum Minimum Avg/MinMax/MinPAY STATION 0.0 fc 0.0 fc 0.0 fc 0.0 0.0VACUUM CANOPY 0.0 fc 0.0 fc 0.0 fc 0.0 0.0PARKING AND DRIVERAISLE0.0 fc 0.0 fc 0.0 fc 0.0 0.0PROPERTY LINE 0.0 fc 0.0 fc 0.0 fc 0.0 0.0