Loading...
HomeMy WebLinkAbout037 - T12 SITE LIGHTING PLAN1T.12SITE LIGHTING PLAN2215 WHEAT DRIVEBOZEMAN, MT 59715ECHO SUITESPROJECT NARRATIVE continued... SITE LIGHTING PLAN 1" = 40'-0" INTENSITY FALLS OFF TO <.3 FC BY 60' FROM BUILDING -WELL BEFORE EXTENT OF LOT BLDG. ENTRANCEBLDG. ENTRANCE BLDG. ENTRANCE BLDG. ENTRANCE ADJACENT NON-CITY OF BOZEMAN RESIDENTIAL / AG USAGE ADJACENT TRAIL EASEMENTTable 38.570.040-1: Security lighting standards. 38.570.040.A.T1 Parking Lot Lighting Average 5.0 maintained footcandles. 38.570.040.B Bldg. Ent. Lighting 38.570.040.B 38.570.040.B 040.G.2. Lighting fixtures are shielded such that no light is emitted above a horizontal plan passing through the lowest point of the light emitting element. 040.G.4. Glare control is achieved through the use of full cutoff fixtures. See: Site Lighting Specs 060.A.1-4. Site lighting is in compliance. 38.570.040.G.2-4 Cutoff Lighting Footcandles at the property line do not exceed 0.3 to adjacent properties. 38.570.040.G.5 Property Line 38.570.060.A.1-4 PERIMETER SITE / PARKING LIGHTING, TYP. -WALL MOUNTED FIXTURES -REF: SITE LIGHTING SPECS 23100 North Park Wyndham SP Review (003) Thu Jan 11, 2024