Loading...
HomeMy WebLinkAbout026 - T01 NARRATIVE AND COVER SHEET1T.01COVER SHEET + NARRATIVE2215 WHEAT DRIVEBOZEMAN, MT 59715ECHO SUITESM-1 ZONING MANDEVILLE LANE B-2 ZONING WHEAT DRIVE WHEAT DRIVE "OTHER" BLOCK FRONTAGE PROJECT LOCATION Project Overview PROJECT NARRATIVE Project Echo is an extended stay hotel. The project consists of a single 4-story hotel structures, with 124 guest rooms and a trash enclosure to serve the hotel. Echo is located at the northwest corner of the Mandeville Lane and Wheat Drive intersection in Bozeman, Montana. The hotel is on leased state property as part of Phase 1 of the North Park Development and is being developed in partnership with Trax Partners, LLC. Zoning: -M-1 industrial zoning. -“Other”block frontage on Wheat and Mandeville. -Determined in prior planning effort for the North Park Development. -2.22 acre / 96,805 ft^2 effective total “lot”area. Setbacks / Easements: -North: 20’Right-of-Way easement. -East: 10’front setback. -South: 10’front setback. -West: 3’rear setback. Project Information Area figures: -12,760 ft^2 building footprint. -4 levels: -Level 1 –12,760 ft^2 -Level 2 –12,970 ft^2 -Level 3 –12,970 ft^2 -Level 4 –12,970 ft^2 -51,670 ft^2 total building area. -53.3% FAR -51,670 ft^2 building area / 96,805 ft^2 lot area. Structure PROJECT ECHO AN EXTENDED STAY HOTEL 2215 WHEAT DRIVE, BOZEMAN, MT 59715 continued... CITY OF BOZEMAN SITE PLAN SUBMITTAL APPLICABLE BUILDING CODES BUILDING: MECHANICAL: PLUMBING: ELECTRICAL: FIRE: ACCESSIBILITY: ENERGY: SCOPE OF WORK: NUMBER OF FLOORS: ALLOWED NUMBER OF FLOORS: CONSTRUCTION TYPE: OCCUPANCY CLASSIFICATION: SPRINKLERED: FAR: SITE COVERAGE: 2021 INTERNATIONAL BUILDING CODE (IBC) + MT ARM RULE 24.301.146 2021 INTERNATIONAL MECHANICAL CODE (IMC) + MT ARM RULE 24.301.172 2021 INTERNATIONAL FUEL GAS CODE (IFGC) + MT ARM RULE 24.301.173 2021 UNIFORM PLUMBING CODE (UPC) (IAPMO) + MT ARM ARM RULE 24.301.301 2020 NATIONAL ELECTRIC CODE (NEC) +MT ARM RULE 24.301.401 2021 INTERNATIONAL FIRE CODE +MT ARM RULE 243.12.601 ADMIN ORDER 2023-04 ADOPTION OF 2021 FIRE CODE ICC A117.1-2017 STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES +2021 ANSI ICC A117.1 2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) + MT ARM RULE 24.301.161 NEW 124 KEY EXTENDED STAY HOTEL 4 4 V-A RESIDENTIAL GROUP R YES (NFPA 13) 53.3% LOT AREA = 96,805 /12,760 FOOTPRINT 32 COB SP #23100 ADOPTED CODES 2021 IBC Basic Design Criteria Deck Live (snow) Load: 46 psf (Pg) ASCE 7 Table 7.2-4 for Montana Ground Snow Load: 46 psf (Pg) Roof Snow Load: 41 psf (Pm) Frost Depth 48" (inches) minimum bottom of the footing Wind Speed: 115 mph Seismic Design Category: D Determine the (soil) site class in accordance with ASCE 7 Site-specific Geotechnical Analysis Required at permit application. THIS INFORMATION WILL BE PROVIDED BY THE ENGINEER OF RECORD AND THE SOILS ENGINEER FOR THE PROJECT. 33 COB SP #23100 DESIGN CRITERIA 23100 North Park Wyndham SP Review (003) Thu Jan 11, 2024