HomeMy WebLinkAbout012 - Utility PlanFSFS FS FS FS FS
FSFS
GM
E
E E EE E E
E EDYHSW 12''S
W
1
2
'
'SWSWSWGS GS GS GS GS GS
GS EEEEEEEEEEEEE
E
EE E E E EEEEEEEEEE
E E ESW
W 4''
SW 12''SW 12''SW 12''
8'-81
8"
10' UTILITY EASEMENT
10' UTILITY EASEMENT
13'-03
4">>>>>>>>>>>>>>>OHP OHP OHP OHP OHP OHP OHP OHP OHP OHT OHT OHT OHT OHT OHT OHT OHT OHT ES ES
ES
ES ES ES ES ES ES ES ES
ES
ES
EW EW EW EW EW EW EW
UGP UGP UGP UGP UGP FO OHTV OHTV OHTV FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO NG NG NG NG NG NG NG EW EW
EW
EW
EW
12 "WATER MAIN
EW UGP ES ES ES ~ * * * * * * * * ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ >>>>>>>>>>>>>>>>>>>>
>>
>>>
>>>>>>>>>>>>>>>>>>>
>>
>>>
>>>>>
>>>>>>>>>>>>>>TSEMEMEEMHSDYH WVEWWVWVWVWVDYH
EEEWVWVETTGWMEW EW EW EW EW
20' WIDE
RIGHT-OF-WAY
EASEMENT
PER DOC.
#2131522
25' WIDE
TRAIL
EASEMENT
20' DRAINAGE
EASEMENT10' UTILITY EASEMENT&
ENGINEERS
PLANNERS
SURVEYORS
DESIGNER
DRAWN
CHECKED
PROJ. NO.
DATE
SURVEYED
DESCRIPTIONDATEREVISION SHEET
OF
2/29/24 13:43 BRYANA.ZUIDERWEG F:\7348 NORTH PARK WYNDHAM HOTEL SITE PLAN\DRAWINGS\DWG\CIVIL\5 SHEET PRODUCTION\06 - UTILITY PLAN.DWG;226
---
DJ&A, P.C.
01/16/2024
7348
MR
BZ
BZ
UTILITY PLAN
BOZEMAN, MT
PROJECT ECHO
NORTH PARK WYNDHAM HOTEL NSCALE IN FEET
0 20 40
GENERAL NOTES
1.CONTRACTOR TO VERIFY EXISTING CONDITIONS
PRIOR TO COMMENCEMENT OF CIVIL-RELATED
WORK.
2.UTILITIES SHOWN ON THE PLANS ARE
APPROXIMATE. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO VERIFY LOCATIONS OF ALL
UTILITIES WITHIN THE PROJECT LIMITS.
3.CONTRACTOR TO VERIFY LOCATION, SIZE,
MATERIAL, AND ELEVATIONS AT CONNECTIONS
WITH EXISTING WATER AND SEWER MAINS.
4.SEE LANDSCAPING SHEETS FOR IRRIGATION
LINES.
5.ELECTRICAL IS SHOWN FOR SCHEMATIC
PURPOSES ONLY. SEE ELECTRICAL SHEETS.
6.SEE GRADING AND DRAINAGE SHEET FOR
STORMWATER DESIGN.
7.COORDINATE WATER AND SEWER CONNECTIONS
TO BUILDING WITH PLUMBING SHEETS.
PROPERTY LINE, TYP.
UNKNOWN UTILITY, CONTRACTOR TO VERIFY
PRIOR TO DEMOLITION, CONTRACTOR TO
PROCEED BASED OWNER DIRECTION
EXISTING 8" PVC SEWER LATERAL
EXISTING 8" DI WATER
MAIN EXTENSION
EXISTING 10" PVC
SEWER MAIN
EXISTING 12" DI WATER MAIN
KEY NOTES
4" WATER SERVICE CONNECTION (SEE CIVIL DETAILS)
4" FIRE SUPPRESSION CONNECTION
FIRE HYDRANT ASSEMBLY (SEE CIVIL DETAILS). CONNECT AND
REDUCE EX. 8" STUB TO 6" FIRE HYDRANT LATERAL
CONNECT 8" SANITARY SEWER LATERAL TO EXISTING 8" STUB
~241' 4" ZINC-COATED DUCTILE IRON WATER SERVICE LINE
~250' of 4" ZINC-COATED DUCTILE IRON FIRE SUPPRESSION MAIN
~85' of 8" PVC SDR 35 SANITARY SEWER LATERAL @ 3.5% SLOPE
EXISTING FIRE HYDRANT (PROTECT IN PLACE)
EXISTING POWER POLE AND APPURTENANCES TO BE
RELOCATED DURING MANDEVILLE LANE IMPROVEMENTS
EMERGENCY POWER OFF SWITCH (SEE ELECTRICAL PLAN)
FDC LOCATION
NWE TRANSFORMER
UNDERGROUND POWER, TYP. (SEE ELECTRICAL PLAN)
PARKING LOT LIGHTING, TYP. (SEE ELECTRICAL PLAN)
TYPICAL US-ORIENTED CLEANOUT (SEE CIVIL DETAILS)
TYPICAL DS-ORIENTED CLEANOUT (SEE CIVIL DETAILS)
1
2
3
4
5
6
7
8
9
10
11
12
2
5
6
7
8
9
4
12
16
GAS SERVICE
CONNECTION TO BE
COORDINATED
WITH NWE GAS SERVICE
METER
(SEE MEP PLANS)
ELECTRICAL ROOM
MECHANICAL ROOM
N
NPSSROF
E
OI
NOM AT A
AL E EEN GINRMICHAEL T.
RUSSELL
No. 59647PE
3
13
UNDERGROUND
POWER CONNECTION
3
1
13
10
14
14
14
14
14
14
13
FUTURE EV
CHARGERS (SEE
ELECTRICAL
PLAN)
14
11
15
16
15
WELL, CONTRACTOR TO VERIFY PRIOR TO
DEMOLITION, CONTRACTOR TO PROCEED
BASED OWNER DIRECTION
EXISTING PULLBOX. CONTRACTOR TO
ADJUST TO GRADE AND ENSURE
PULLBOX IS TRAFFIC-RATED.
20-FT PUBLIC
DRAINAGE
EASEMENT
PUBLIC
UTILITY
EASEMENT
10 FT FRONT
SETBACK/FUTURE
UTILITY EASEMENT,
TYP.