30"x24"30"x36"GENERATOR
COMMON AREA AIR
HANDLING UNIT
AHU
1 RESIDENTIAL CONDENSING UNITS
TYPICAL OF 27
CONDENSING UNITS
TYPICAL OF 27
AHU
130"x36"
3 0 "x 2 4 "
COMMON AREA AIR HANDLING UNIT
GENERATOR
ACE JOB 23HL5778
3060 CABERNET DR.
SUITE 3
HELENA, MT 59601
406-204-2400
N
S
SHEET NO.:
TITLE:
COPYRIGHT 2023 SMA, P.C.
REVISIONS:
KEYMAP:
ARCHITECT/ENGINEER SEAL:
PROJECT:
PROJECT LOCATION:
PREPARED FOR:
OWNER LOGO:
CONSULTANT LOGO/CONTACT:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
TEAM:
PHASE:
DATE:
SMA PROJECT NUMBER:Plot Date:NOT FOR CONSTRUCTION
AHJ APPROVAL:
HELENA
P: 406-442-4933
BOZEMAN
P: 406-219-2216
www.sma.design
7/28/2023 10:48:10 AMM2.61
22-099
2023-07-31
MECHANICAL ROOF PLAN -
SOUTH
LJ
RG
811 WEST MENDENHALL
APARTMENTS
22-099
811 West Mendenhall Street
Bozeman, MT 59175
Arel Capital / Boundary Development
SITE PLAN REVIEW
MECHANICAL KEYNOTES
MECHANICAL GENERAL NOTES
A GENERAL CONTRACTOR SHALL CUT ALL FLOORS, WALLS, CEILINGS, AND ROOF AS
REQUIRED TO PERFORM THE WORK DEPICTED IN THESE CONTRACT DOCUMENTS AND
SPECIFICATIONS. GENERAL CONTRACTOR SHALL PATCH ALL ASSOCIATED FLOORS,
WALLS, CEILINGS, AND ROOF AS REQUIRED TO THE SATISFACTION OF THE
ARCHITECT/ENGINEER.
B COORDINATE EXACT LOCATION OF DIFFUSERS AND GRILLES WITH REFLECTED CEILING
PLAN AND LIGHTING LAYOUT.
C FLEX DUCT RUN OUTS SHALL BE LIMITED TO 5'-0".
D COORDINATE HVAC AND PLUMBING EQUIPMENT WITH ALL OTHER TRADES AS
REQUIRED.
E ALL CEILING DIFFUSERS TO BE 4-WAY UNLESS OTHERWISE NOTED.
F DUCT PENETRATIONS THROUGH ROOF TO BE COORDINATED WITH JOIST LAYOUT.
G ALL DUCTS ABOVE CORRIDOR AREAS TO BE MINIMUM 24 GAUGE SHEET METAL.
H PROVIDE FLUSH CUP CONCEALED OPERATORS ON ALL HAND DAMPERS LOCATED ABOVE
HARD CEILINGS.
I LINE ALL SUPPLY AND RETURN DUCTS WITH 1" A.L. WITHIN 15' OF FANS.
J ALL DUCT DIMENSIONS SHOWN ON PLANS ARE CLEAR INTERIOR DIMENSIONS.
K PROVIDE LOCKING COVERS FOR ALL THERMOSTATS/SENSORS.
L PROGRAMMABLE THERMOSTATS SHALL BE PROVIDED WITH NEW BATTERIES AT TIME OF
SUBSTANTIAL COMPLETION.
M PROVIDE ACCESS PANELS FOR EACH FIRE DAMPER PER IMC STANDARDS/REQUIREMENTS.
N VERIFY EXACT LOCATION OF T-STATS WITH ARCHITECT PRIOR TO INSTALLATION.
O SEAL ALL MECHANICAL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES WITH
UL-APPROVED FIRE RATED SYSTEM.
N
1/8" = 1'-0"M2.61
1 MECHANICAL ROOF PLAN - SOUTH
NO.DATE REVISION DESCRIPTION
N
M2.61
2 ROOF MECHANICAL EQUIPMENT ISOMETRIC
SITE PLAN REVIEW