HomeMy WebLinkAbout061 Roof Lighting Plan - SouthLV PP
OS
OS
nK
PP
11
11
G G
L L
F F
1
1
3
3
10
10
6
6
12
12
13
13
7
7
8
8
2
2
H H
K K
5
5
9
9
J J
4
4
UPPER
STAIR/ELEV
LOBBY
6002
STAIR
S-1
W2
H1-9
GENERATOR
W2
C1
C1 C1
C1 C1
C1
H2-10nP9
n
nP9 n
C1 C1 C1 C1 C1
C1
C1
ACE JOB 23HL5778
3060 CABERNET DR.
SUITE 3
HELENA, MT 59601
406-204-2400
N
S
SHEET NO.:
TITLE:
COPYRIGHT 2023 SMA, P.C.
REVISIONS:
KEYMAP:
ARCHITECT/ENGINEER SEAL:
PROJECT:
PROJECT LOCATION:
PREPARED FOR:
OWNER LOGO:
CONSULTANT LOGO/CONTACT:
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
TEAM:
PHASE:
DATE:
SMA PROJECT NUMBER:Plot Date:NOT FOR CONSTRUCTION
AHJ APPROVAL:
HELENA
P: 406-442-4933
BOZEMAN
P: 406-219-2216
www.sma.design
11/21/2023 2:24:20 PME3.61
22-099
2023-11-21
ROOF LIGHTING PLAN -
SOUTH
NP
DV
811 WEST MENDENHALL
APARTMENTS
22-099
811 West Mendenhall Street
Bozeman, MT 59175
Arel Capital / Boundary Development
SPR FIRST CYCLE RESPONSES
ELECTRICAL LIGHTING GENERAL NOTES
A REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL INFORMATION ON DEVICE
LOCATIONS, DIMENSIONS, ETC. CAREFULLY EXAMINE ARCHITECTURAL FLOOR PLANS,
CEILING PLANS, ELEVATIONS, ETC. FOR INFORMATION THAT AFFECTS ELECTRICAL
WORK. NOTIFY ARCHITECT/ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN
ARCHITECTURAL AND ELECTRICAL PLANS.
B ALL DARK ITEMS ARE NEW, UNLESS NOTED OTHERWISE. ALL SHADED ITEMS ARE EXISTING
TO REMAIN.
C ALL ITEMS DENOTED WITH AN (R) ARE RELOCATED OR REINSTALLED. ALL ITEMS
DENOTED WITH AN (E) ARE EXISTING TO REMAIN.
D MODIFY AND REUSE EXISTING CIRCUITS WHERE POSSIBLE. CIRCUITING SHALL BE AS
SHOWN BUT CIRCUIT NUMBERS MAY BE CHANGED TO MAKE USE OF EXISTING
AVAILABLE CIRCUITS. PROVIDE NEW BREAKERS AND WIRING AS NEED TO
ACCOMMODATE NEW CIRCUITING.
E CONNECT ALL LIGHTING FIXTURES TO EXISTING LIGHTING CIRCUITS UNLESS NOTED
OTHERWISE. VERIFY EXISTING LOAD PRIOR TO CONNECTING ADDITIONAL LIGHTING
FIXTURES.
F CONNECT ALL EXIT SIGNS AND EMERGENCY FIXTURES TO EXISTING EMERGENCY
CIRCUITS SUPPLYING AREA UNLESS NOTED OTHERWISE, WIRING NOT SHOWN.
G LOW VOLTAGE WIRING FOR OCCUPANCY SENSORS AND POWER PACKS NOT SHOWN.
PROVIDE POWER PACKS AND WIRING AS REQUIRED FOR ALL OCCUPANCY SENSORS.
H VERIFY VOLTAGE OF EXISTING LIGHTING CIRCUITS PRIOR TO SUBMITTALS. COORDINATE
ANY MODIFICATIONS TO LIGHTING CIRCUITS OR FIXTURES WITH ENGINEER.
I PROVIDE UNSWITCHED HOT CONDUCTOR FROM LOCAL LIGHTING CIRCUIT TO ALL
EMERGENCY AND EXIT FIXTURES.
J WHEN LIGHT SWITCHES ARE SHOWN LOCATED ON THE WALL THAT IS COMMON WITH
THE END OF THE DOOR SWING INTO A SPACE, DO NOT LOCATE THE SWITCHES BEHIND
THE DOOR BUT RATHER A MINIMUM OF 6” FROM THE END OF THE SWING. VERIFY EXACT
DOOR SWING PRIOR TO ROUGH-IN.
K FIRE SEAL ALL PENETRATIONS IN FIRE RATED WALLS. COORDINATE WITH
ARCHITECTURAL FOR LOCATIONS.
ELECTRICAL KEYNOTES
NO.DATE REVISION DESCRIPTION
N
1/8" = 1'-0"E3.61
1 ROOF LIGHTING PLAN - SOUTH
SITE PLAN REVIEW