Loading...
HomeMy WebLinkAbout054 Electrical Cover SheetCOMMUNICATION DEVICES FIRE ALARM DEVICES ESV F F M DSD S V PP J PP OS OS POWER DEVICES M T LIGHTING DEVICES V W R NA D ELECTRICAL ABBREVIATIONS ELECTRICAL LEGEND INTERIOR MOUNTING HEIGHTS AS F F F FACP LAA FS TS PS ARRP ARMP CB CO2 CO2 M JJ THERMOSTAT BY MC, ROUGH-IN BY EC PAD MOUNTED UTILITY TRANSFORMER CEILING MOUNTED SPEAKER COMBINATION WALL SPEAKER/ CLOCK UNIT MANUAL PULL STATION AUDIO/VISUAL HORN/STOBE DEVICE VISUAL STROBE DEVICE MAGNETIC DOOR HOLDER SMOKE DETECTOR HEAT DETECTOR CARBON MONOXIDE DETECTOR SPRINKLER CONNECTION, PRESSURE SWITCH SPRINKLER CONNECTION, TAMPER SWITCH SPRINKLER CONNECTION, FLOW SWITCH SPRINKLER CONNECTION, LOW AIR ALARM DUCT SMOKE DETECTOR FIRE SMOKE DAMPER FIRE ALARM CONTROL PANEL FIRE ALARM REMOTE ANNUNCIATOR ELEVATOR SHAFT VENT, CONNECT TO FIRE ALARM SYSTEM VOICE DEVICE JACK, BOX INDICATES FLOOR MOUNTING CABLE TV JACK INTERCOM JACK WALL MOUNTED SPEAKER WALL MOUNTED VOLUME CONTROLLER WALL CLOCK DUPLEX RECEPTACLE SUBSCRIPT INDICATES TYPE: DOUBLE DUPLEX RECEPTACLE, SUBSCRIPT ABOVE INDICATE TYPE DUPLEX RECEPTACLE IN FLOOR BOX DOUBLE DUPLEX RECEPTACLE IN FLOOR BOX SIMPLEX RECEPTACLE MOTOR CONNECTION VARIABLE FREQUENCY DRIVE MUSHROOM HEAD PUSH BUTTON SIMPLEX RECEPTACLE IN FLOOR BOX PHOTO CELL WALL MOUNTED CLOCK HANGER/ POWER RECEPTACLE CORNER WALL MOUNTED OCCUPANCY SENSOR CEILING MOUNTED OCCUPANCY SENSOR, STYLE 1 CEILING MOUNTED OCCUPANCY SENSOR, STYLE 2 CEILING MOUNTED OCCUPANCY SENSOR, STYLE 3 FUSED DISCONNECT SWITCH NON-FUSED DISCONNECT SWITCH COMBINATION STARTER/DISCONNECT SWITCH CO2 DETECTOR BY MC, ROUGH-IN BY EC CONTACTOR MANUAL MOTOR STARTER SINGLE POLE SWITCH, SUBSCRIPT INDICATES TYPE: LAY-IN OR RECESSED LIGHTING FIXTURE SURFACE MOUNTED LIGHTING FIXTURE DIRECT/ INDIRECT LIGHTING PENDANT MOUNTED FIXTURE. SURFACE MOUNTED OR CHAIN HUNG STRIP FIXTURE WALL BRACKET LIGHTING FIXTURE SURFACE MOUNTED CYLINDER FIXTURE WALL MOUNTED FIXTURE FILLED CENTER OR SLASH INDICATES FIXTURE IS AN EMERGENCY DEVICE WITH EMERGENCY BATTERY PACK OR CONNECTED TO EMERGENCY POWER. EXIT SIGN, BRACKET INDICATES WALL MOUNTING. NUMBER OF FACES AND DIRECTION INDICATED BY FILLED AREAS. DOUBLE HEAD WALL MOUNTED BATTERY PACK POWERED EGRESS FIXTURE. SQUARE HEAD POLE MOUNTED SITE LIGHT FIXTURE. ROUND HEAD POLE MOUNTED SITE LIGHT FIXTURE. RELAY 1'-6"FINISHED CEILING FINISHED FLOOR COD COD COD TOD 44"54"74" TO TOP OF TRIMBOD 80" MINIMUM TO BOTTOM84" AFF TO BOTTOM OF DEVICE OR 6"BELOW CEILING TO TOP OF DEVICE,WHICHEVER IS LOWER.WATT MISER WITH WATT(S) WIRE VESTIBULE VOLT(S) UNIT HEATER UNDERGROUND TELEPHONE UNDERGROUND ELECTRICAL UNDERGROUND TYPICAL TELEVISION TELEPHONE BACK BOARD SWITCH STORAGE STEEL STANDARD SPECIFICATIONS SWITCH, PILOT SOLID NEUTRAL SHEET SUPPLY FAN SERVICE RAPID START RESTROOMS ROOM(S) ROOM REQUIRED REFRIGERANT REFRIGERATOR RECEPTACLES RECEPTACLE RETURN AIR FAN PROVIDE & INSTALL PRODUCE PREPARATION PANEL PHASE OVERHEAD OFFICE OVERCURRENT PROTECTION NUMBER NOT IN CONTRACT LIGHT WHITE LIGHTS KILOWATT(S) KILIVOLT AMPERE(S) KITCHEN WM W/ W W VEST V UH UGT UGE UG TYP TV TBD SW STOR STL STD SPECS SP SN SHT SF SER RS RR RMS RM REQD REFR REF RECPTS RECP RAF P/I PROD PREP PNL P OH OFF OCP NO NIC LW LTS KW KVA KIT JUNCTION BOX INCORPORATED HERTZ HOT WATER HEATER HEATERS HOT WATER HEIGHT HIGH INTENSITY DISCHARGE HIGH PRESSURE SODIUM HORSEPOWER GROUND FAULT CIRCUIT INTERRUPTER FOOT FULL LOAD AMPS FIXTURE FACILITY FIRE ALARM EXTERIOR ELECTRIC WATER COOLER ETCETERA ENGINEER EMERGENCY ESTIMATED MAXIMUM DEMAND ELECTRIC EXHAUST FAN COOL WHITE CABLE TELEVISION COPPER CONTRACTOR CONDENSER COMPRESSOR COMMISSARY CIRCUIT CABINET UNIT HEATER CUBIC FEET PER MINUTE CIRCUIT BREAKER CONDUIT BRITISH THERMAL UNIT/HOUR BREAKER BUILDING APPROXIMATE APPLIANCE AMPERE(S) AIR HANDLING UNIT ABOVE FINISH FLOOR ADMINISTRATION ADJUSTABLE AIR CONDITIONING UNIT AIR CONDITIONING CONDENSING UNIT AMP(S) J-BOX INC HZ HWH HTRS HW HT HID HPS HP GFCI FT FLA FIX FAC FA EXT EWC ETC ENGR EMER EMD ELEC EF CW CTV CU CONTR COND COMP COMM CCT CUH CFM CB C BTU/HR BRK BLDG APPROX APPL AMP AHU AFF ADMIN ADJ ACU ACCU A ALUMINUMAL VOLT AMPERESVA ATS AUTOMATIC TRANSFER SWITCH CWP COLD WATER PUMP HWP HOT WATER PUMP SDP SUB DISTRIBUTION PANEL KILOHERTZKHZ CCTV CLOSED CIRCUIT TELEVISION COM COMMUNICATION FACP FIRE ALARM CONTROL PANEL RA REMOTE ANNUNCIATOR GFI GROUND FAULT INTERRUPTER EC ELECTRICAL CONTRACTOR GENERAL CONTRACTORGC XFMR TRANSFORMER SPST SWITCH, SINGLE POLE- SINGLE THROW 48"COD AQUASTAT BY PLUMBING CONTRACTOR, WIRED BY EC. SITE GROUND MOUNTED FLOOD FIXTURE REMOTE DOUBLE HEAD EGRESS FIXTURE AREA OF RESCUE ASSISTANCE -REMOTE STATION AREA OF RESCUE ASSISTANCE -MASTER STATION WALL SCONCE FIXTURE COD 36"AUDIO SPEAKER DEVICE CEILING MOUNTED AUDIO/VISUAL SPEAKER/STROBE DEVICE CEILING MOUNTED AUDIO SPEAKER DEVICE ADDRESSABLE INTERFACE DEVICE BY EC FOR FIRE/SMOKE DAMPERS DUPLEX RECEPTACLE, CEILING MOUNTED. DEVICE AND COVER SHALL MATCH CEILING FINISH SPECIAL PURPOSE CONNECTION, BRACKET INDICATES WALL MOUNTING, BOX INDICATES FLOOR MOUNTING COMBINATION VOICE/ DATA DEVICE JACKS, BOX INDICATES FLOOR MOUNTING 208V SINGLE PHASE RECEPTACLE, CONFIGURATION NOTED ON PLANS 208V THREE PHASE RECEPTACLE, CONFIGURATION NOTED ON PLANS OCCUPANCY SENSOR POWER PACK, BOX INDICATES WALL MOUNTING JUNCTION BOX, BRACKET INDICATES WALL MOUNTING, BOX INDICATES FLOOR MOUNTING ELECTRICAL PANEL - SEE PANEL SCHEDULES FOR MOUNTING CONFIGURATION RECESSED DOWN LIGHT, HALF MOON INDICATES WALL WASH TRIM AND DIRECTION. S C SSC C FSD FAA OS OS 1 2 3 VFD SD HD CO F C R C AC = MINIMUM 4" ABOVE BACKSPLASH TO BOTTOM OF DEVICE. SWITCHED DUPLEX RECEPTACLE, BOX INDICATES DEVICE LOCATED IN FLOOR BOX PC SECURITY SYSTEM DEVICES MS MS KP CCTV MS MRX CLOSED CIRCUIT CAMERA KEY PAD CEILING MOUNTED MOTION SENSOR CORNER MOUNTED MOTION SENSOR WALL MOUNTED MOTION SENSOR MOTION REQUEST TO EXIT SENSOR CR CARD READER DOOR POWER SUPPLY DISCONNECT DIAMETER DPS DISC DIA DRAWINGDWG MFG MANUFACTURER MOUNTED MAIN PANEL MAIN LUGS ONLY MINIMUM MECHANICAL MAIN CIRCUIT BREAKER MTD MP MLO MIN MECH MCB MAIN DISTRIBUTION PANELMDP MFA MINIMUM FEEDER AMPACITY MC MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPSMCA MAXIMUM OVERCURRENT PROTECTION MOCP MOMENTARY CONTACTMOC AC GFCI IG TR U WP WR ABOVE COUNTER GROUND FAULT CIRCUIT INTERRUPTER ISOLATED GROUND TAMPER RESISTANT USB WEATHERPROOF WEATHER-RESISTANT FILLED CENTER INDICATES GFCI DEVICE 2 3 4 D K LV MC OS P T 2-POLE 3-WAY 4-WAY DIMMER KEYED LOW VOLTAGE MOMENTARY CONTAC OCCUPANCY SENSOR PILOT LIGHT TIMER - 1 HOUR TIMER, MOTOR RATED FOR EXHAUST FANS EL ELECTRIC LOCK ES ELECTRIC STRIKE CM ADDRESSABLE CONTROL MODULE MM ADDRESSABLE MONITORING MODULE PRX PUSHBUTTON REQUEST TO EXIT SENSOR T F B FF MISCELLANEOUS LEGEND NORMAL CIRCUIT CONCEALED IN WALL OR EXPOSED UNDERGROUND OR BURIED CIRCUIT HOMERUN TO ELECTRICAL PANEL NUMBER OF HASH MARKS INDICATES NUMBER OF CURRENT CARRYING CONDUCTORS. NO MARKS INDICATES TWO. GROUNDING CONDUCTOR NOT SHOWN BUT SHALL BE INCLUDED IN ALL CONDUITS. W/ WITH AC ABOVE COUNTER EC ELECTRICAL CONTRACTOR (E) EXISTING (R)RELOCATED (N)NEW DEVICE C BFG BELOW FINISHED GRADE UC UNDER COUNTER WP WEATHER PROOF MC MECHANICAL CONTRACTOR REFER TO ELECTRICAL NOTES AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE WM WIRE MOLD GC GENERAL CONTRACTOR GND GROUND UG UNDER GROUND BOD BOTTOM OF DEVICE TOD TOP OF DEVICE COD CENTER OF DEVICE BOF BOTTOM OF FIXTURE PC PLUMBING CONTRACTOR CONDUIT 1 ACE JOB 23HL5778 3060 CABERNET DR. SUITE 3 HELENA, MT 59601 406-204-2400 N S SHEET NO.: TITLE: COPYRIGHT 2023 SMA, P.C. REVISIONS: KEYMAP: ARCHITECT/ENGINEER SEAL: PROJECT: PROJECT LOCATION: PREPARED FOR: OWNER LOGO: CONSULTANT LOGO/CONTACT: PROJECT NUMBER: DRAWN BY: CHECKED BY: TEAM: PHASE: DATE: SMA PROJECT NUMBER:Plot Date:NOT FOR CONSTRUCTION AHJ APPROVAL: HELENA P: 406-442-4933 BOZEMAN P: 406-219-2216 www.sma.design 11/21/2023 2:24:06 PME0.00 22-099 2023-11-21 ELECTRICAL COVER SHEET NP DV 811 WEST MENDENHALL APARTMENTS 22-099 811 West Mendenhall Street Bozeman, MT 59175 Arel Capital / Boundary Development SPR FIRST CYCLE RESPONSES NO.DATE REVISION DESCRIPTION ELECTRICAL SHEET LIST E0.00 ELECTRICAL COVER SHEET E1.00 ELECTRICAL PHOTOMETRIC SITE PLAN E1.01 PHOTOMETRIC ELEVATIONS E1.02 ELECTRICAL SITE PLAN E1.03 PHOTOMETRIC ROOF PLAN E1.04 SPR LUMINAIRE CUTSHEETS E3.60 ROOF LIGHTING PLAN - NORTH E3.61 ROOF LIGHTING PLAN - SOUTH LUMINAIRE SCHEDULE CALLOUT MANUFACTURER MODEL MOUNTING LAMP ELECTRICAL DATA DESCRIPTION C3 PORTFOLIO LDS4C 15 90 30 D010 S 0 ** RECESSED LED 120 V/1-16 VA COORDINATE FINISH WITH ARCHITECT. W2 LUMIERE 9003 W1 RW LED3090 W M BK L2 UNIV RSM WALL LED 120 V/1-20 VA SITE PLAN REVIEW