Loading...
HomeMy WebLinkAboutArchitect_002_070121 roof plan GENERAL NOTES STAMP 1. G.C.SHALL VERIFY LOCATION AND SIZE OF ALL ROOF OPENINGS AND EQUIPMENT PLATFORMS REQUIRED. 2. G.C.SHALL VERIFY HVAC UNITS,ELECTRICAL,GAS,AND CONDENSATE DTAIN PENETRATION WITH HVAC/REFRIGERATION MANUFACTURER CONNECTIONS. 3. G.C.SHALL PROVIDE FLASHING,COUNTER FLASHING AT ALL EQUIPMENT CURBS AND BENTS WHERE THEY OCCUR. 12 4. LOCATION OF MECHANICAL,ELECTRICAL,PLUMBING AND FIRE PROTECTION SYSTEMS ARE TO RELATE TO CEILING SYSTEM ELEMENTS. O 5. REFER TO PLUMBING DRAWINGS FOR PLUMBING VENTS AND PIPES THROUGH ROOF WHICH MAY NOT BE SHOWN ON THIS ROOF PLAN.PROVIDE FLASHING AND OS COUNTER FLASHING TO MECHANICAL EQUIPMENT CURBS AND ALL VENTS. TYP. KEYED NOTES 1 L 13 1. NEW 30"X36"ROOF HATCH WITH BILCO SAFETY POST#S-50;RE:STRUCTURALAND L 20 DETAILS I&4/A4.4 //-�� D Ol 2. ROOF PENETRATION,ROOF CURB FOR EXHAUST FAN,GRAVITY VENT,AC UNIT;RE: / ' U MECHANICAL PLANS&10/A4.4,STRUCTURAL PLANS FOR SUPPORT. iy W 3. REFRIGERATION EQUIPMENT&PLATFORM;RE:5/A4.4-AND STRUCTURAL PLANS. TYR. 4. CURBED ROOF OPEN'G W/RAINHOOD FOR REFRIGERATION LINES;ROOF PER PENETRATION,CURB&RAINHOOD ASSEMBLY BY G.C.;RE:STRUCTURAL& U REFRIGERATION PLANS&DETAIL 2/4.4. FT.MIN. L_ 1/4"PER 14 5. G.I.PARAPET COPING;PRE-FINISH TO MATCH"COOL GRAY 11C"BY PANTONE. m 20 FT.MIN. VERIFY COLOR WITH EXTERIOR ELEVATIONS ON A3.0. 06 6. G.C.TO PROVIDE POWER FOR ALL SIGNS INCLUDING,EXTERIOR J-BOXES, CONDUITS,CIRCUITS AND HOME RUNS AS REQUIRED.SIGNAGE UNDER SEPARATE PERMIT. 13 -_ - 7. DASHED LINE DENOTES FULL HEIGHT WALL OR CURTAIN WALL BELOW ROOF. 1STYP. 13 B. METAL'CANOPY AND FRAME,RE:A3.0 FOR MATERIALAND COLORS&DETAILS F- 21/A4.4&1/A4.1. 69CC�` �L-J 15 1 - - - - - - 9. NEW 60MIL SINGLE PLY TPO ROOFING 0/R20 RIGID INSULATION.RE:SPECIFICATIONS _ - MANUAL. 15 L 10 RECOMMENDATIONS. RDROHATCH GUARDRAIL.INSTALL PER MANUFACTURER'S 11. TRUCK DOCK,RE:SLAB PLAN AND FLOOR PLAN. RIDGE 18 OS 12. CMU SCREEN WALL AT TRUCK DOCK,RE:EXTERIOR ELEVATIONS. TYP. TVP. /� ix 13. DRAINAGE CRICKETS AT CURBED EQUIPMENT TYP.,PLACE SUCH THAT DRAINAGE V A WILL FLOW AROUND UNITS. 9 14. CONCRETE SIDEWALK BELOW1TT J FT.MIN. 15. ROOFTOP MECHANICAL UNIT,RE:MECHANICAL,ELECTRICAL,PLUMBING PLANS. W TVP. 09 16. REFRIGERATION CONDENSER UNIT,RE:REFRIGERATION&ELECTRICAL PLANS. W 17. HVAC CONDENSER UNIT,RE:5/A4.4&MEP DWGS. m 16 TYP 18. WALK PADS RE:SPECS. O 19. NOT USED. 20. BUILT UP INSULATION CRICKETS UNDER TPO ROOFING. 06 7-T 13 21. METAL CANOPY,RE:18/A4.4&EXTERIOR ELEVATION ON A3.0. U) W {� 22. OVERFLOW,RE:12/A4.4&21/A4.4. > 23. INTERIOR UNIT HEATER SHOWN FOR REFERENCE ONLY.REFER TO HVAC PLANS. 13 1 1 I 7 - �iL - 24. STEP IN CMU WALL,RE:A3.0 ,2 T LO 04 V T W RIDGE N LEGEND � z iy 13 OM\ Q LL W (99 WALK PADS RE:SPECS O O �ti 9 JQY 16 18 TYP. 1/4"PER O W Lezzo Fr. Z rr/•�� 03 14 O U � II I I `� it lien: �- 1/4"PER L J 15 15 IN. L J TERRAFORM COMPANIES 6770 S.900 E.,STE:102 RIDGE SALT LAKE CITY,UT 84047 Contact:ELLIOTT SMITH Tel.No.:(801)573-0444 A ZO 09 7YP. PER � REVISIONS No. Description Date 17 os TVP. 05 24 06 TYP. SHEET INFORMATION 14 roject No.: HS21-00 1q raven By: DJ evi-ed By: DJ ate: 06.29.21 Sheet Title: N PRELIMINARY ROOF PLAN Sheet#: A2.0 PRELIMINARY ROOF PLAN SCALE J