Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
019 - A211 - PROPOSED FLOOR PLAN - MAIN LEVEL
DN DN A4112 A411 1 A412 2 A412 1 VINTAGE STOVE (OFCI) VINTAGE STOVE (OFCI) PROP. GATE (VEHICULAR TRAVEL) PROP. RAISED PLANTER PROP. ENTRY STAIR & HR & GUARDRAIL PROP. WDW IN (E) OPENING PROP. RAISED PLANTER PROP. WDW IN (E) OPENING PROP. WDW IN (E) OPENING PROP. ADA PLATFORM LIFT REPAIR (E) BRICK AS REQUIRED, TYP. PREP. WALL FOR PAINT. PAINT COLOR PER SPECIFICATIONS PROP. BALCONY PROP. 50/50 DR IN ENLARGED (E) OPENING PROP. DR IN (N) OPENING PROP. OH DR IN (E) OPENING PROP. WDW IN ENLARGED (E) OPENING REPAIR (E) BRICK AS REQUIRED, TYP. PREP. WALL FOR PAINT. PAINT COLOR PER SPECIFICATIONS PROP. WDW IN (E) OPENING PROP. WDW IN (E) OPENING PROP. EGRESS WDW WELL W/ LADDER PROP. EGRESS WDW WELL W/ LADDER PROP. WDW IN (E) OPENING PROP. STAIR AND HR PROP. GATE (PEDESTRIAN TRAVEL) PROP. DR IN (E) ENLARGED OPENING PROP. ENTRY DR IN ENLARGED (E) OPENINGSV.I.F.37' - 11 1/2"81' - 10 1/2" 1' - 6" LINE OF ROOF OVERHANG 2' - 5 3/4"V.I.F. 81' - 10 1/2"10' - 3 1/4"1' - 0"4' - 2 1/4"103 102 101101 109108103112111104 107106 110 104 105 114PROP. GATE KP AND KNOX BOX 1 A302 1 A302 1 A301 1 A301 2 A301 2 A301 1 A303 1 A303 2 A302 2 A302 2 A303 2 A303 105 CAST IRON ELECTRIC RADIATOR, TYP. CAST IRON ELECTRIC RADIATOR, TYP. CAST IRON ELECTRIC RADIATOR, TYP. KITCHEN 02 OFFICE/DINING/LIVING 03 BATHROOM 06 STORAGE 05 TOILET 08 SHOWER 07 ADA RESTROOM 09 SCULLERY 12 NORTH ENTRY 01 STORAGE 10 WEST ENTRY 11 W1 W1 W1W1 W1W2 W1 W2 W5 W7 W7 W7 W7 W5 W5 12' - 11 1/8"5' - 5 1/2"5' - 7 1/8"5' - 8 5/8"25' - 1 3/4"16' - 10"7' - 8 3/4"1 1/2"1 1/2"7' - 2 3/8"5' - 7 1/2"10' - 4 3/8"4' - 9 7/8"7' - 7 3/8"1 1/2"18' - 4"1' - 10"8' - 11 3/4"1' - 9 3/4"8' - 9"3' - 8 7/8"3' - 0 5/8"7' - 4 3/4" 1' - 6 5/8" 6' - 0"1 1/2"14' - 3 1/4"4' - 10 1/2"4' - 11 3/4"13' - 10 1/8"1 1/2"5' - 4 3/8"3' - 11 3/4"3' - 6 3/4"5' - 2"3' - 1 1/4"1 1/2"3' - 0 1/4"6' - 0"9' - 0"3' - 4 1/8"1 1/2"4' - 5 1/2"1' - 10 1/8"2' - 6"1' - 6"3' - 7 1/8"2' - 5 1/2"4' - 7"4' - 2" 7' - 9 1/2" 1 1/2" 5' - 11"8' - 9" 3' - 8 7/8" 3' - 0 5/8"2' - 3"2' - 11 1/8"3' - 6 7/8"2' - 6" 4 1/8" 1' - 8 1/4"4' - 6 1/4" 119 120 W2 A6018 9 A601 10 11 A601 12 W9 W5 W5 W5 W53' - 5 1/4"10' - 11 1/4"W2 BEDROOM 04 5' - 1" R @0' -6"6 R @ 0' -6"6 R @ 0' -6 219/256"7 PLAN NOTES 1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 2. THE CONTRACTOR SHALL NOT CONSIDER CONSTRUCTION NOTES TO BE ALL-INCLUSIVE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA AND TO FULFILL THE INTENT OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL COORDINATE ARCHITECTURAL CONSTRUCTION DRAWING AND NOTES WITH CIVIL, STRUCTURAL AND MECHANICAL, ELECTRICAL & PLUMBING NOTES AND DRAWINGS. 3. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS PRIOR TO COMMENCING WORK. 4. ALL FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED TO ENSURE A UNIFORM APPEARANCE AND SEAMLESS TRANSITION. 5. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES; COORDINATE LOCATIONS. 6. ALL DIMENSIONS ARE FROM STRUCTURAL GRIDLINES OR UNFINISHED FACE OF STUD, UNLESS OTHERWISE NOTED. 7. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING CONSTRUCTION. 8. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL INCONSISTENCIES IN FLOOR ELEVATIONS. 9. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE SUBSTRATE FOR FINISHES. 10. LOCATE THE HINGE SIDE JAMB OF DOORS 4 1/2" FROM ADJACENT PERPENDICULAR WALL, UNLESS NOTED OTHERWISE. 125 NORTH WALLACE AVE. BOZEMAN, MT 59715 DATE ISSUED: CURRENT REVISION #: CURRENT REVISION DATE: PROJECT NUMBER: A211 FLOOR PLAN - MAIN LEVEL 2207PROJ. #2207702 EAST MAIN702 EAST MAIN STREETBOZEMAN, MONTANA 59715SP/CCOA11/22/2023 1/4" = 1'-0"1 PROPOSED MAIN LEVEL FLOOR PLAN 0'2'4'8'16'N