HomeMy WebLinkAbout005 - A030 - TYPICAL DETAILS - ADA CLEARANCECL CL CL CLCL CL CLCL CL CL CL CL CL CL CL CL Landing Ramp Run Landing Ramp Run Landing Ramp RunFig. 405.7 Edge Protection and Handrail Extensions (a) Straight (b) Change in Direction Lavatories and Mirrors Fig. 602.5 Drinking Fountain Spout Location (b) ElevationANSI 606 + 1002.11.2.2 Side Mirror per 603.3 Lever Hardware per 309.4 Bowl Depth shall be 6 1/2" Min. per 606.5 Exposed Pipes shall be Insulated or otherwise Configured to protect against contact per 606.6 Knee and Toe clearances per 306.3 (a) Plan WheelchairAccessibleStandingPersonsReinforced Areas for installation of Grab Bars and Seat Control Wall Transfer-Type Shower Control Area per 608.5 Shower Spray Unit shall be Provided w/ a Hose 59" Long Min. and can be Used as a Fixed or Hand-Held Shower 36" Adjustable Shower Bar shall not Obstruct the use of Grab Bars The Control shall be located 10" from the Center to the Open Side of the Bathtub and 43" above the Bathroom Floor Reinforced Areas for installation of Grab Bars and Seat Reinforced Areas for installation of Grab Bars and Seat Reinforced Areas for installation of Grab Bars and Seat Reinforced Areas for installation of Grab Bars and Seat Back Wall Seat per 610.3 Note: Grab Bar not Req'd at Time of Construction where reinforment has been provided per 1002.11.1 Note: Grab Bar not Req'd at Time of Construction where reinforment has been provided per 1002.11.1 Seat Wall The Control shall be located 10" from the Center to the Open Side of the Bathtub and 43" above the Bathroom Floor Shower Spray Unit shall be Provided w/ a Hose 59" Long Min. and can be Used as a Fixed or Hand-Held Shower 36" Adjustable Shower Bar shall not Obstruct the use of Grab Bars Control Area per 608.5 Note: Grab Bar not Req'd at Time of Construction where reinforment has been provided per 1002.11.1 Control Wal Roll-in Type Shower ANSI 608 + 1002.11.2 ANSI 608 + 1002.11.2 Back Wall Note: Grab Bar not Req'd at Time of Construction where reinforment has been provided per 1002.11.1 Note: Removeable In-tub Seat not Req'd per 1002.11.6 Head End WallFoot End Wall ANSI 607 + 1002.11.2 Control Area per 608.5 Tub/Shower Spray Unit shall be Provided w/ a Hose 59" Long Min. and can be Used as a Fixed or Hand-Held Shower The Control shall be located 8" from the Center to the Open Side of the Bathtub and 24" above the Bathroom Floor Fig. 608.2.3 Alternative Roll-in Type Shower Compartment Size and Clearance Note: Inside Finished Dimensions Measure at the Center Points of the Opposing Sides Back Wall Control WallSeat Wall Fig. 608.2.1 Transfer-Type Shower Compartment Size and Clearance Fig. 610.3.2 L-Shape Shower Compartment Seat Fig. 608.4.3 Alternative Roll-in Type Shower Control and Hand Shower Location Fig. 608.2.2 Standard Roll-in Type Shower Compartment Size and Clearance Fig. 608.3.1 Grab Bars in Transfer-Type Showers Side Wall Side Wall Front Wall Back Wall Side Wall Side Wall Back Wall Control Wall Fig. 604.3 Size of Clerance for Water Closet Communication Features Intercom/Directory Directory Highest Control Lowest Control ANSI 702 + 1006 Note: Dwelling Unit Smoke Dectector shall include Audible Notification complying with NFPA 72 Wall Alarm w/ Smoke Detector Wall Alarm (a) Fig. 604.9.2 Wheelchair Accessible Compartments (b) (b) Floor Mounted Water Closet - Wall Hung(b) Wall Hung Water Closet Clear Floor Space Dispenser SideFront ANSI 604 + 609 ANSI 609 + 1002.11.2 SideFront Dispenser Toilet Controls to be on Open Side • • Note: Grab Bar not Req'd at Time of Construction where reinforment has been provided per 1002.11.1 Grab bar to be installed 33"- 36" AFF measured to top of bar per ANSI 2009: Sect 604.5.1 Fig. 505.10.3 Bottom Handrail Extensions at Stairs Note: X+ Tread Depth (a) Fig. 505.10.1 Top and Bottom Handrail Extensions at Ramps 4" to 6 1/4" Perimeter (a) (a) (b) Circular Cross Section Non-Circular Cross Section Radius 1/2" Max. (c) Curved Nosing (d) Beveled Nosing (a) Radius of Tread Edge (Typical for all Profile) (d) Beveled Nosing Fig. 504.2 Treads and Riser for Accessible Stairways (a) Stairs Fig. 504.5 Stair Nosing Fig. 505.4 Handrail Height (b) Ramps (c) Walking Surfaces Fig. 505.5 Handrail Clearance Handrail height should be measured to the top of the gripping surface ANSI 2009: Sect 505.4, Typical. The bottom of reinforcement for the horizontal grab bar should be positioned no higher than 30" above the finish floorto accommodate adequate installation of grab bars required by ANSI positioned at 33" AFF. • Note: Bottom edge to be at 27" max. to avoid being a protruding object Per (ANSI 2009 Section 307.2) Accessible threshold 1/2" max. Provide sufficient reinforcement. Allowable stresses shall not be exceeded for materials used where a vertical or horizontal force of 250 pounds is applied at any point on the seat, fastener mounting device, or supporting structure. ANSI 2009: Sect 610.4 60" Min. 60" Min. 60" Min.60" Min.At Least asWide as Ramp RunTo Bottom of Reflecting Surface40" Max.27" Min.34" Min.5" Max. 15" Min.36" Max.38" - 43" 36" Min.18" Min.15" Min.43".48".1'-6" Min. 15" - 16" 2 1/2" Max. 36" Min 3/8"9/32" 36" Min. 36" Min. 15".18".48".43".60" Min. 1/8" 1/8"30" to 36"48".27" Max. 15" - 16" 12" Max. 24" Max.9".17" - 19"33" - 36" 12" Min. 4" Max.18".4".24" - 36" 36" Min.36" Min.52" Min.36" Min. 36" Min. 36" Min. 2 1/2" Max. 15"-16" 22"-23"1 1/2" Max.14"-15"3" Max.6" Max.6" Max 6" Max. 60" Min.30" Min.30" Min.18".4" Max.70" Max.4"-12"80"-96"60" Min.56" Min.18" Min.66" Min.60" Min. 60" Min 56" Min.18". 4" Max.12" Min.52" Min.59" Min.36" Min.6" Max. 60" min 42" Min. 16"-18"7"-9"15" Min.33"-36"18" Min.33"-36"12" Max. 39"-41" 54" Min.17"-19"33"-36"12" Min. 24" Min. 36" Min.17"-19"12" Min.24" Min. 36" Min. 7"-9"15" Min.33" to 36"1 1/2" Min.54" Min. 12" Max. 12" Min. 12" Min. X X 2" Max. 1 1/4" Min.2 1/4" Max.4" - 7" 3 0 ° Max. 1 1/2" Max.1 1/2" Max.34" to 38"1 1/2" Min.1 1/2" Min.34" to 38"34" to 38"30" max38" min30" max38" min38" min6" max38" min30" max27" Max27" Max30" Max38" Max30" max38" Min30" max38" Min125 NORTH WALLACE AVE. BOZEMAN, MT 59715 DATE ISSUED: CURRENT REVISION #: CURRENT REVISION DATE: PROJECT NUMBER: A030 TYPICAL DETAILS - ADA CLEARANCE DETAILS 2207PROJ. #2207702 EAST MAIN702 EAST MAIN STREETBOZEMAN, MONTANA 59715SP/CCOA11/22/2023 ADA CLEARANCE DETAILS