HomeMy WebLinkAbout31_C 3.15_WATER DETAILS (CONT.)PARTDESCRIPTION53FIRE HYDRANTFIRE HYDRANTFIRE HYDRANT LEAD PIPEGATE VALVE & VALVE BOXFIRE HYDRANT SPECFIRE HYDRANT LOCATION SPECNOTES:CoBOZEMAN MOD'S TO MPWSS, DRAWING NO. 02660-05CoBOZEMAN MOD'S TO MPWSS, DRAWING NO. 02660-046" GATE VALVE W/ VALVE BOX6" DI CLASS 51MUELLER SUPER CENTURION 250PARTDESCRIPTION52WATER SERVICEDISTANCE FROM PROPERTY LINEMIN BURY DEPTHCURB STOP VALVECURB STOP VALVE BOXCOMPRESSION CONNECTIONWATER SERVICE LINENOTES:1" TYPE K ANNEALED COPPER PIPE1" MUELLER (MODEL H-15403)MULLER H10388 CURB BOX 1 ¼” WITH A 2 ½” BASE TAPPING1" MUELLER BALL VALVE (MODEL B-25155)6.5'VARIESPARTDESCRIPTION54CORPORATION STOPCORPORATION STOP1" MULLER B-25008SERVICE SADDLE1" MUELLER BR 2 B SERIES1" WATER SERVICE LINE1" TYPE K ANNEALED COPPER PIPE1.5" WATER SERVICE1.5" TYPE K ANNEALED COPPER2" WATER SERVICE 2" TYPE K ANNEALED COPPERNOTES:PARTDESCRIPTION58BLOWOFF-HYDRANTBLOW OFF HYDRANTMUELLER H-15428 O.A.E.WATER SERVICE LINE1" TYPE K ANNEALED COPPER PIPE SERVICE SADDLE2" MUELLER BR 2 B SERIESNOTES:PARTDESCRIPTION56GATE VALVEGATE VALVEVALVE BOXNOTES:EJIW 8560 SERIES MUELLER 2360 PARTDESCRIPTION51UTILITY TRENCHTRENCH WIDTHOUTSIDE Ø OF PIPE(S) + 3'PIPE BEDDING MATERIALTYPE 1MINIMUM DEPTH OF COVER4'INSULATION1" = 1'DETECTABLE WARNING TAPE DEPTH1.5' MINIMUM, 2' MAXIMUM BELOW GROUND SURFACEHORIZ. SEPERATION DIST. FROM SEWER10' MINIMUMVERTICAL SEPERATION DISTANCE1.5' MINIMUMNOTES:NOTES: ALL SPEC'S O.A.E. VIA CoBOZEMAN MOD'S TO MPWSSHIGH DENSITY RIGID FOAM INSULATION1" = 1' BURY DEPTH, 4' WIDE SHEETSPARTDETAILSTYPICAL INSULATION SCHEDULE57SCALE: N.T.S.59DIRECTIONAL DRILL CASING SPACERCARRIERPIPE6'-8' BETWEEN SPACERS(PER MANUFACTURER)14" Ø SCH 40A53 STEEL PIPECASINGID= 13.13"CASINGSPACERS(TYP.)C900 PVCCARRIER PIPEOD= 9.05"CARRIER PIPEBELL ODNOTES:1.CASING SPACERS SHALL BE CCI POLYETHELENE CASING SPACER MODELCSPB08-1.50. ALTERNATE CASING SPACERS MAY BE USED WITH PRIORAPPROVAL FROM THE ENGINEER.2.INSTALL END SEALS AT BEGINNING AND END OF CASING PIPE.3.CASING SPACERS AND END SEALS SHALL BE INSTALLED PERMANUFACTURERS SPECIFICATIONS. USE A "CENTERED" CONFIGURATIONAND PROVIDE THE MANUFACTURER WITH CARRIER PIPE OD, CASING PIPEID, AND CASING LENGTH.C3.15AS NOTEDWATER DETAILS (CONT.)MALHEC Nov 20, 2023 - 9:17pmCAD FILE: M:\203430\Drawings\PHASE 2\CONSTRUCTION DRAWINGS\3.10 - WATR DETAILS.dwg REVISIONSDATEPROJECT NUMBERHYALITE Engineers, PLLC2304 N 7th Ave. Ste. LBozeman, MT 59715Tel: (406) 587.2781w w w . hyaliteeng. comFax: (406) 522.92252018URBAN + FARM BOZEMAN, MT11.17.2023203430PRELIMINARY 22x34 ORIGINALSSCALESHEET TITLEDESIGN BYLAUREL PARKWAY LLC11 LONE PEAK DRIVEBIG SKY, MT 59716PHASE 2 MONTANABRETT C.No. 29106 PEMEGAARDPEFORSOILNASREN I G ENE P R E L I M I N A R Y