HomeMy WebLinkAbout005 - A102 FLOOR PLANJEFFERY A.KANNING
BILLINGSMT
1482 ANMO
NT
A
STO F
ATE
AR C TIH TCEDSE
N
E
C
IL 1482
JEFFERY A.KANNING
BILLINGSMT
COPYRIGHT C
PREPARED FOR :PROJECT NUMBER:PROJECT ARCHITECT :
ISSUE DATES:CITY VINEYARD T.I.
2825 WEST MAIN STREET, BOZEMAN, MT 59718
BECKY RENO JEFF KANNING 2327
REV0 PERMIT SET
10/4/2023 - REV0 PERMIT SET
-
-
-
-
2023 A102
FLOOR PLAN
- C O L L A B O R A T I V ED E S I G N A R C H I T E C T S2327 - CITY VINEYARD T.I.2280 GRANT ROAD, SUITE C BILLINGS, MT 59102 406.248.3443www.cd-mt.comA R C H I T E C T S
THESE DOCUMENTS, IN PART OR IN WHOLE, AND THEDESIGN THEY REPRESENT ARE THE SOLE PROPERTY OFCOLLABORATIVE DESIGN ARCHITECTS. THESEDOCUMENTS ARE INTENDED FOR THE PROJECT ON THESITE INDICATED. ANY USE, REPRODUCTION,MODIFICATION OR ADAPTATION WITHOUT THE EXPRESSWRITTEN CONSENT OF COLLABORATIVE DESIGNARCHITECTS IS STRICTLY PROHIBITED.
DC E F GBA
111A
111B 106A107A
10
A706
4
A705
1
A701
2
A102
6'-31/2"5'-11"37'-4"8'-111/2"7'-7"9'-6"4'-2"2'-91/2"10'-11/2"5'-11"4'-0"OPENING7'-1"4'-7"
6'-4"7'-0"6'-10"6'-2"4'-0"13'-10"7'-0"3'-0"3'-10"6'-21/2"6'-0" OPENING71/2"16'-8"3'-4"10'-7"8'-21/2"4'-3"4'-1"2'-6"3'-0"2'-2"7'-0"1'-9"4'-11"3'-7"8'-3"3'-9"
43'-7"
26'-101/2"101/2"9'-7"5'-71/2"5'-11"5'-0"4'-11"7'-0"1
1
1 1
1
2 4 5
01
01
01
01
01
01
8
01
01
01
01
01
WH
ELEC.
AREA NOT IN SCOPE
RETAIL
110
EXISTING
MALL
102
EXISTING
R.R.
103
EXISTING
R.R.
104
EXISTING
EXTERIOR
PATIO
WORK
ROOM
111
1'-2"12'-6"
1
01
6
7
7
9
10
11
12
11
11
11
1111
11
11
11
11
11
13
14
3
01 7
15
16
M.S.
HALL
105
OFFICE106
WALK
IN
COOLER
107
BAR
105
EXISTING
VESTIBULE
100
LOUNGE
105
2
4
3
PLAN
WALL TYPE 01FLOOR PLAN KEYNOTES
1. LOCATION OF EXISTING STRUCTURAL COLUMN.
2. ELECTRICAL METER, PANELS & GEAR PER ELECTRICAL DRAWINGS.
3. GAS METER PER MECHANICAL DRAWINGS.
4. HOT WATER HEATER LOCATION. SEE PLUMBING.
5. LOCATION OF MOP SINK. SEE PLUMBING.
6. NEW STEEL COLUMN TO MATCH EXISTING COLUMN
7. SOFFIT ABOVE - SEE REFLECTED CEILING PLAN FOR MORE
INFORMATION.
8. PARTIAL WALL - SEE DETAIL 5 /A707 FOR MORE INFORMATION
9. OPENING IN CEILING ABOVE
10. BUILT-IN CUSTOM WINE RACK SYSTEM - BY TENANT
11. BUILT-IN CASEWORK
12. WALK IN COOLER - BY TENANT
13. STEEL RAILING SYSTEM - SEE DETAIL 2/A102
14. STEEL GATE SYSTEM
15. WALL WITH NO INSULATION AND SEE DETAIL 7/A701 FOR WALL HEIGHT
INFORMATION
16. SEE ELEVATION 2/A701. BAR WALL IS SUSPENDED FROM WALL AND
STARTS AT 3'-0" A.F.F.3'-0" TOP OF RAILING A.F.F.EXISTING
CONCRETE
PATIO
TUBE STEEL
RAILING SYSTEM
POWDER COAT
SHERWIN
WILLIAMS
URBANE BRONZE
HORIZONTAL
TUBE STEEL
RAILING SYSTEM
CONCRETE ANCHOR
- INSTALL PER
MANUFACTURER'S
RECOMMENDATIONS
STEEL BASEPLATE
- PER
ENGINEERING
REQUIREMENTS
INTERIOR WALL 01
1
COMPONENTNOTE
2
FIRE RESISTANCE RATING
N/ASTC RATING
ASSEMBLY THICKNESS 7 1/4"
3
4
INTERIOR SHEATHING:
STRUCTURE:
CAVITY INSULATION:
INTERIOR FINISH:
MATERIAL
N/A
6" 20 GA. STEEL STUD
5/8" TYPE 'X' GYP BOARD
LISTING
N/A
N/A
R-19 BATT INSULATION
1
A102
FLOOR PLAN
1/4" = 1'-0"
2
A102
RAILING DETAIL
1 1/2"= 1'-0"
4,247 SF LEASABLE AREA
FLOOR PLAN GENERAL NOTES:
1. ALL WALLS ARE DIMENSIONED TO EDGE OF STUD.
2. ALL INTERIOR WALLS EXTEND FROM SLAB TO B.O. DECK.
3. FIRE EXTINGUISHER CABINETS SHALL BE SEMI-RESSED IN WALLS.
4. ALL GLAZING IN DOORS & WINDOWS WITHIN 24 INCHES OF DOORS SHALL
BE SAFETY GLAZED OR TEMPERED.
5. ALL INTERIOR WALLS TO BE SOUND INSULATED. 6" WALLS TO BE R-19.
DESCRIPTIONGRAPHIC
PARTITION GRAPHIC LEGEND
1 HOUR FIRE/SMOKE PARTITION
EXISTING WALL
NEW WALL PARTITION