HomeMy WebLinkAbout024_L2.2IrrigationDetailsSP SUBMITTALFILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION----IRRIGATION DETAILSMAIN STREET HOTELCONSTRUCTION PLANSBOZEMAN, MTL2.2 RPEBOZ_07022_01_LS_DETAILS.DWGDME5/24/20221ST SITE PLAN SUBMITTAL8/15/202211/3/2023----COVER SHEET REVISION2ND SITE PLAN SUBMITTAL------BOZ-07022.01ALMJMCFROM WATER
SOURCE
TO IRRIGATION
SYSTEM
GROUND LEVEL
BACKFLOW PREVENTOR
METER
BLOWOUT TEE WITH CAP
COPPER PIPE
MAIN LINE
(PVC PIPE)
COPPER PIPE 1.5' MINPIPE STRAP
INTERIOR WALL
INTERIOR POINT OF CONNECTION
N.T.S.
NOTES:
1.SEE MECHANICAL FOR INTERIOR CONNECTION.
1
12"
NOTES:
1.USE TEFLON TAPE FOR ALL THREADED PIPE
CONNECTIONS.
2.ALL WIRES TO BE INSTALLED AS PER LOCAL CODES. NO
''IN-LINE'' WIRE SPLICES WILL BE ALLOWED.24"PVC MALE ADAPTOR & LATERAL LINE
FINISHED GRADE
12" STANDARD VALVE BOX
DRAIN GRAVEL
1 CU. FOOT
SCH.80 UNION
CENTER VALVE IN BOX
SCH.80 NIPPLE
SCH.40 PVC SXT 90\
CLASS 200 PVC PIPE
CONTROL WIRES
SCH.40 PVC TEE OR 90
ANGLE TO DIRECT
LATERAL IN TRENCH
SUCH THAT PIPE IS NOT
CURVED OR OTHERWISE
STRESSED.DOUBLE VALVE BOXES
BOLTED BACK TO BACK
ELECTRIC CONTROL VALVE
N.T.S.2
18"
PLANS
SECTIONS
DIRECT BURY PLAN
DIRECT BURY SECTION
TAPE & BUNDLE ALL WIRING AT 10' INTERVALS.
USE 6" WIDE MARKING TAPE 6" ABOVE ALL
DIRECT BURIAL WIRING.
ALL SPLICES SHALL BE MADE IN VALVE BOXES
AND LOCATED ON AS-BUILT PLANS (ALL 120 V).
WIRING SHALL BE IN CONDUIT WITH MARKER
TAPE AS ABOVE.
ALL WIRING UNDER PAVEMENT & THROUGH
SLEEVES SHALL BE IN CONDUIT. TIE A LOOSE 20
INCH LOOP IN WIRING AT ALL CHANGES IN
DIRECTION GREATER THAN 30 DEGREES. UNTIE
ALL LOOPS AFTER MAKING CONNECTIONS.
18"
CONDUIT SECTION
CONDUIT PLAN
24" 36" 24" 36"
LATERAL PIPE IN
TRENCH SNAKE ALL
FINISHED GRADE
MARKING TAPE
LOOP
TIES
FINISHED GRADE
LATERAL
MAIN LINE
BEDDING
LOW VOLTAGE WIRE OR 120V WIRE IN CONDUIT
LATERAL
TRENCHING DETAILS
N.T.S.3
1
2
3
4
1
2
3
NOTES:
1.MOUNT CONTROLLER LCD SCREEN AT EYE
LEVEL, CONTROLLER SHALL BE HARD-WIRED
TO GROUNDED 110 VAC POWER SOURCE
4
LEGEND:
4
IRRIGATION CONTROLLER
IRRIGATION CONTROL WIRE IN CONDUIT
SIZE AND TYPE PER LOCAL CODES
ELECTRICAL SUPPLY CONDUIT
CONNECT TO POWER SOURCE, J-BOX INSIDE
CONTROLLER
ADJACENT SURFACE TO MOUNT CONTROLLER PER
PLAN
CONTROLLER - WALL MOUNT
N.T.S.
RIGHT ELEVATION
FRONT ELEVATION
4
NOTES:
1.COVER DRIP LATERAL AND EMITTER DISTRIBUTION TUBING WITH
MULCH, ALL PLANTING BEDS.
2.BURY TUBING AT 6" DEPTH IN OPEN AREAS.
'RAINBIRD EMITTER, INLINE OR
XB-10,AT BASE OF EACH
PLANTING
RAINBIRD XT-700 1/2" DRIP
TUBING
6" STL. STAPLE AT 6' O.C. MAXIMUM
ALONG DRIP LATERAL; NOT REQUIRED
WHERE DRIP LATERAL IS BURIED
FINISH GRADE
WEED BARRIER LANDSCAPE FABRIC, TYP.
SECTION
DRIP EMITTER
N.T.S.6 POP-UP SPRAY HEAD
N.T.S.
4"
FINISH GRADE
POP-UP SPRINKLER BODY.
SEE SPECIFICATION FOR
TYPE.
WALK/CURB
(3) MARLEX STREET ELLS
FLEXIBLE PIPE
SCH. 40 P.V.C. TEE
NOTES:
1. NIPPLE AND STREET ELL DIAMETERS SHALL EQUAL INLET
SIZE SPRAY BODY.
7
3"
FINISHED GRADE
PVC SCH 40 ELL
PVC SCH 80 NIPPLE (LENGTH AS REQUIRED)
30" LINEAR LENGTH OF WIRE, COILED
WATERPROOF CONNECTION: SPLICE-1 (1 OF 2)
ID TAG
VALVE BOX WITH COVER
PVC SCH 40 FEMALE ADAPTER
LATERAL PIPE
BRICK (1 OF 4)
3" MINIMUM DEPTH OF 3/4" PEA GRAVEL
CONTROL ZONE KIT: (INCLUDES 1" VALVE, BACK FLUSH
PRESSURE REGULATING FILTER, DUCK BILL BOOT).
PVC SCH 80 NIPPLE (2-INCH LENGTH,
HIDDEN) AND PVC SCH 40 ELL
PVC SCH 40 TEE OR ELL
PVC MAINLINE
1" DRIP ZONE KIT
N.T.S.5
P:\BOZ_07022_01_Main_Street_Hotel_Bozeman_Civil\CADD_C3D\PRODUCTION_DWG\BOZ_07022_01_LS_DETAILS.dwg, IRRIGATION DETAILS, 11/3/2023 2:28:24 PM, amartoncik, 1:1