Loading...
HomeMy WebLinkAbout022_L2.0IrrigationScheduleSYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY PSI HUNTER MP STRIP PROS-04-PRS40-CV TURF ROTATOR, 4" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. LST=IVORY LEFT STRIP, SST=BROWN SIDE STRIP, RST=COPPER RIGHT STRIP. 8 40 HUNTER MP1000 PROS-04-PRS40-CV TURF ROTATOR, 4" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC. 4 40 HUNTER MP2000 PROS-04-PRS40-CV TURF ROTATOR, 4" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC. 6 40 SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY HUNTER ICZ-101-25 DRIP CONTROL ZONE KIT. 1" ICV GLOBE VALVE WITH 1" HY100 FILTER SYSTEM. PRESSURE REGULATION: 25PSI. FLOW RANGE: 2 GPM TO 20 GPM. 150 MESH STAINLESS STEEL SCREEN. 5 AREA TO RECEIVE DRIP EMITTERS HUNTER RZWS-18 18" LONG RZWS WITH INSTALLED .25 GPM OR .50 GPM BUBBLER OPTIONS, 1/2" SWING JOINT FOR CONNECTION TO 1/2" PIPE 324.8 S.F. 25 emitters (2 assigned to each 1-1/2" MIN. CAL. plant)26 AREA TO RECEIVE DRIP EMITTERS RAIN BIRD XB-PC SINGLE OUTLET, PRESSURE COMPENSATING DRIP EMITTERS. FLOW RATES OF 0.5 GPH=BLUE, 1.0 GPH=BLACK, AND 2.0 GPH=RED. COMES WITH A SELF-PIERCING BARB INLET X BARB OUTLET. 5,561 S.F. 05PC emitters (1 assigned to each 4" POT plant)29 10PC emitters (1 assigned to each 1 GAL. plant)241 20PC emitters (3 assigned to each 1-1/2" MIN. CAL. plant)24 20PC emitters (1 assigned to each 2 GAL. plant)58 20PC emitters (1 assigned to each 5 GAL. plant)151 SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY HUNTER ICV-G 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC REMOTE CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT THREADED INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE. 2 FEBCO 850 1" DOUBLE CHECK BACKFLOW PREVENTION, 1/2" TO 2"1 HUNTER IC-1200-M MODULAR CONTROLLER, 12 STATIONS, OUTDOOR MODEL, METAL CABINET. COMMERCIAL USE. WITH ONE ICM-600 MODULE INCLUDED. 1 POINT OF CONNECTION 1 IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 1,559 L.F. IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 547.7 L.F. C1 NUMBER MODEL SIZE TYPE GPM DESIGN PSI PSI PSI @ POC PRECIP 1 Hunter ICZ-101-25 1"Area for Drip Emitters 2.32 10 13.2 0.8 in/h 2 Hunter ICZ-101-25 1"Area for Drip Emitters 4.5 25 30.5 0.16 in/h 3 Hunter ICZ-101-25 1"Area for Drip Emitters 3.11 10 13.8 0.38 in/h 4 Hunter ICV-G 1"Turf Rotary 5.78 40 42.9 0.34 in/h 5 Hunter ICZ-101-25 1"Area for Drip Emitters 5.28 10 15.3 0.31 in/h 6 Hunter ICV-G 1"Turf Rotary 0.89 40 42.0 0.27 in/h 7 Hunter ICZ-101-25 1"Area for Drip Emitters 2.5 25 28.4 0.06 in/h SP SUBMITTALFILE:PROJECT NO:CAD:QUALITY ASSURANCE:DRAWING HISTORYDATE DESCRIPTION----IRRIGATION SCHEDULE & NOTESMAIN STREET HOTELCONSTRUCTION PLANSBOZEMAN, MTL2.0 RPEBOZ_07022_01_LS_IRRIGATION.DWGDME5/24/20221ST SITE PLAN SUBMITTAL8/15/202211/3/2023----COVER SHEET REVISION2ND SITE PLAN SUBMITTAL------BOZ-07022.01KAAJMCIRRI*ATION S&HE'ULE ESTIMATE' :ATER &ONSUMPTION IRRI*ATION NOTES 1.THIS SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 55 PSI, AT A MAXIMUM DISCHARGE OF 15 GPM AT THE 1" POINT-OF-CONNECTION. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. 2.THE IRRIGATION SYSTEM POINT-OF-CONNECTION SHALL BE IN MECHANICAL ROOM IN BUILDING AT SOURCE PROVIDED APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION/ANTI SIPHON ASSEMBLY PER CITY & STATE BUILDING CODES. VERIFY EXACT LOCATION OF P.O.C. WITH OWNERS REPRESENTATIVE. 3.CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE. FINAL LOCATION TO BE APPROVED BY OWNERS REPRESENTATIVE. 4.COORDINATE UTILITY LOCATES OF ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 5.COORDINATE SLEEVING PRIOR TO ALL HARDSCAPE INSTALLATION. 6.DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE CONSIDERED IN THE DESIGN PROCESS. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 7.DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: A.ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE OF PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE, WIRING, VALVES, ETC. IN LANDSCAPED AREAS AND WITH PROPERTY LINES. B.TREE AND SHRUB LOCATION SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. C.USE ONLY STANDARD TEES AND ELBOW FITTINGS. 7.PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: A.TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES AND CONTROLLERS. 8.THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. IRRIGATION CONTRACTOR TO COORDINATE WITH SITE CONTRACTOR FOR TIME OF INSTALLATION AND LOCATION OF ANY SLEEVE AND/OR CONDUIT INSTALLATION. 9.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10.ALL PLANT MATERIAL NOT LOCATED IN LAWN AREAS SHALL BE DRIP IRRIGATED BY AUTOMATIC CONTROLLED SYSTEM. HUNTER EQUIPMENT OR EQUAL. A COMPLETE LIST OF EQUIPMENT, SHOP DRAWING CATALOG CUTS, LAYOUT PERFORMANCE AND MAINTENANCE WARRANTY INFORMATION SHALL BE SUBMITTED TO THE OWNERS REPRESENTATIVE FOR APPROVAL PRIOR TO COMMENCING WORK. SAID INFORMATION SHALL BE COMPILED ALONG WITH AS-BUILT DRAWINGS AND MAINTENANCE INSTRUCTION AND SUBMITTED TO OWNER'S REPRESENTATIVE FOR APPROVAL AT FINAL COMPLETION. CONTRACTOR SHALL DEMONSTRATE COMPLETE OPERATING SYSTEM AND MAINTENANCE TO OWNER'S REPRESENTATIVE AND OWNER'S MAINTENANCE AND OPERATING PERSONNEL. 11.CONTRACTOR SHALL BE REQUIRED TO START UP AND WINTERIZE SYSTEM FOR THE WARRANTY PERIOD, ONE YEAR FROM FINAL COMPLETION, AND MAKE ALL ADJUSTMENTS AND REPAIRS REQUIRED TO INSURE EFFICIENT OPERATION. 12.CONTRACTOR SHALL PROVIDE ALL REQUIRED IRRIGATION WATER CONTROL, FILTRATION PRESSURE REGULATION, WASTE AND DRAINAGE REQUIREMENTS OF A COMPLETE MAINTENANCE SYSTEM. 13.CONTRACTOR SHALL PROVIDE 2- ROOT ZONE WATERING SYSTEMS TO EACH TREE IN TREE WELL, 3 EACH 2 G.P.H. EMITTERS TO EACH TREE, 2 EACH 1 G.P.H. EMITTERS TO EACH 2 GALLON AND 5 GALLON SHRUB, VINE OR HERBACEOUS PLANT AND 1 EACH 1 G.P.H. EMITTERS TO EACH 1 GALLON AND 4" POT SHRUB, VINE OR HERBACEOUS PLANT. ALL EQUIPMENT SHALL BE CONCEALED OR OTHERWISE PROTECTED UNDER SPECIFIED MULCHES AND IN VALVE BOXES WHERE ACCESS IS REQUIRED. 9AL9E S&HE'ULE NUMBER MODEL TYPE PRECIP IN./WEEK MIN./WEEK GAL./WEEK GAL./DAY ACRE FEET/YEAR 1 HUNTER ICZ-101-25 AREA FOR DRIP EMITTERS 0.8004 1 75.0 173.8 57.9 2 HUNTER ICZ-101-25 AREA FOR DRIP EMITTERS 0.1587 1 378.1 1701.3 567.1 3 HUNTER ICZ-101-25 AREA FOR DRIP EMITTERS 0.3817 1 157.2 488.6 162.9 4 HUNTER ICV-G TURF ROTARY 0.3426 1.5 262.7 1518.1 506.0 5 HUNTER ICZ-101-25 AREA FOR DRIP EMITTERS 0.3144 1 190.8 1007.5 335.8 6 HUNTER ICV-G TURF ROTARY 0.2748 1.5 327.5 291.2 97.1 7 HUNTER ICZ-101-25 AREA FOR DRIP EMITTERS 0.0638 1 940.4 2351.1 783.7 TOTALS:2331.7 7531.6 2510.5 0.42 TOTALS BASED ON 18 WATERING WEEKS A YEAR. 4 4