HomeMy WebLinkAbout008_C4.2 - Civil DetailsSCALE: N.T.S.186" OUTLETNDS DURASLOPECATCH BASINDS-340NDS DURA SLOPETRENCH DRAINSECTION 114NDS DURA SLOPETRENCH DRAINSECTION 113TOP OF CONCRETENOTES:1. TRENCH DRAIN TO BE USED IS NDS DURA SLOPE OR EQUIVALENT EQUAL.2. NDS DURA SLOPE PRODUCTS TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS4'4'2'TRENCH DRAIN SECTIONNDS DURA SLOPETRENCH DRAINSECTION 112NDS DURA SLOPETRENCH DRAINSECTION 111NDS DURA SLOPETRENCH DRAINSECTION 110NDS DURA SLOPETRENCH DRAINSECTION 109NDS DURA SLOPETRENCH DRAINSECTION 1084'4'4'4'4'NDS DURA SLOPETRENCH DRAINSECTION 114NDS DURA SLOPETRENCH DRAINSECTION 113NDS DURA SLOPETRENCH DRAINSECTION 112NDS DURA SLOPETRENCH DRAINSECTION 111NDS DURA SLOPETRENCH DRAINSECTION 110NDS DURA SLOPETRENCH DRAINSECTION 109NDS DURA SLOPETRENCH DRAINSECTION 1084'4'4'4'4'4'4'58'13.5"
13.5"
11.5"
11.5"SCALE: N.T.S.19FIRE SERVICE RISEREL. = 4818.20'TOP of ADAPT./SPOOL (4")THRUST BLOCKEL. = 4819.204" F.S. LINEEL. = +/-4812.08'4" Ø CL. 51 D.I. 90° BENDTHRUST BLOCKINGw/ MJ FITTINGSFIRE SERVICE LINE GENERAL NOTES:1. THE FIRST FITTING INSIDE THE BUILDING SHALL BE A UL LISTED FLANGED OS&YVALVE THE SAME SIZE AS THE FIRE SERVICE LINE.2. HORIZONTAL INSTALLATIONS MUST BE A MINIMUM OF 2' ABOVE THE FINISHEDFLOOR.3. THE FIRE SERVICE RISER MUST BE A MINIMUM OF 2' CLEAR FROM ANY OUTSIDEWALL, AND A MINIMUM OF 1' CLEAR FROM ANY INTERIOR WALLS.4. THE INCOMING FIRE SERVICE LINE SHALL BE A MINIMUM 6.5', AND A MAXIMUMOF 7.5' BELOW THE FINISHED GRADE.5. ALL FIRE SERVICE LINE APPURTENANCES SHALL HAVE A MINIMUM PRESSURERATING OF 175 psi.6. ALL FIRE SERVICE LINES 4" OR LARGER SHALL BE CLASS 51 DUCTILE IRONPIPING.7. INSTALL THRUST BLOCKING PER COB STANDARD DETAIL No. 02660-1.8. INSTALL FIRE SERVICE LINE PER COB STANDARD DETAIL No. 02660-13. FIRESERVICE LINE CLASSIFICATION FOR BACKFLOW PREVENTION IS CLASS I9. PROVIDE FLEXIBLE, WATER-TIGHT CONNECTION FOR ALL WALL AND FLOORPIPE PENETRATIONS.10. SYSTEM IS A CLASS III SYSTEM.PROCESS PIPINGFLOOR SLABPIPE SLEEVE SCHEDULEPIPE SIZESLEEVE SIZE2"6"4"8"6"10"SCH 40 PVCPIPE SLEEVE -SEE SCHEDULECAULK SEALON BACKINGMATERIAL5/8" Ø REDI ROD. (TYP. OF 2).INSTALL FROM MJ 90° BENDTO FLANGE AT O.S.&Y. VALVE.INSTALL NON-ADJACENT AT 2OF THE 4 MJ BOLT HOLES.4" Ø CL. 51 D.I. PIPE.INSTALL PLUMB ANDLEVEL.BLDG. F.F. ELEVATIONTOP OF SLAB (VERIFY W/ ARCH)FLANGE TO BE THREADED ONSTANDPIPE. MJ TO FLANGEADAPTERS ARE NOT ACCEPTABLE.4" OSY VALVE (ENDTHIS PROJECT)4" FLANGED MUELLER O.S.&Y.RESILIENT WEDGE GATEVALVE. POSITION PARALLELWITH ADJACENT WALL.FIRE SUPRESSIONEQUIP. (BY OTHERS)EXISTING WATER MAINC4.2AS NOTEDCIVIL DETAILS CONT.MALHEC Nov 02, 2022 - 9:48amCAD FILE: M:\213611\Drawings\SITE PLAN\1 - Civil Details.dwg
REVISIONSDATEPROJECT NUMBERHYALITE Engineers, PLLC2304 N 7th Ave. Ste. LBozeman, MT 59715Tel: (406) 587.2781w w w . hyaliteeng. comFax: (406) 522.92252018812/818 BOZEMAN, MT05/27/2022213611PRELIMINARY DRAWING SET - 22x34 ORIGINALS WEST BABCOCKSCALESHEET TITLEDESIGN BYMONTANABRETT C.No. 29106 PEMEGAARDPEFORSOILNASREN
I
G
ENEPRELIM
INARY