Loading...
HomeMy WebLinkAbout018 SHEET-C-2-UTILITIES — —— = ! --- - - - - - - - - - - - - --------------------------———--- ----------------- __________ __ __ 1=—===__ _ ----------- ----- -----___---__ -- Su —SD 15"RCP FS 15"RCPS^ S Sr Sn 15•'RCP INSTALLNEWS 15"COPPER S S^u S FALLON ST-37'TBC TO TBC EXISTING 8" WATERSERVICE EXISTING 8" SEWER MAIN SEWER MAIN u 8"PVC S S y EXISTING 12" 8"PVC INSTALL NEW O mq D.I.WATER 4"D.I.FIRE INSTALL NEW WW W 12"WATER MAIN W W SERVICE 4"PVC SEWER W W ERI E _ \_\ -- r 111 SM— SMi CONNECTT ROPERTY BOUNDARY -1o'sETBncK ? EXISTING 4" _�VCSF-WER SEWCE————— LP-- — —i2'-RUE=— ———_— - _——_ _ II - - --------------- 3 t DESIGNATION AS PER I FINAL PLAT(J-231) 1 u o 1 I III O a jj j rn INSTALL 1-- O INSTALL NEW TX 6'CONC.PAD I - 0 n In 4"PVC SEWER INSTALL SEWER FOR MAILBOXES III j m j } SERVICE CLEANOUTS j ; (MANS YePERFN I III jjj 3 a M ti III O 1 P1 OFFICE I -_ � III i x _ BUILDING(1) II I I II V) 0 IL I � METERS GAS&POWER IS I II I III III -5 -HT -bu o I I N jIII - 2 0 1�I I III j3 III H I p l l u j I P2 OFFICE L-3-8 � L-1-1 I III III -3-4 BUILDING(3) 0 \ III METERS (L \ \ \ GAS&POWER \ I C) STALL "EL C \ INSTALL BUILDING \ ��60 DUITS-3' OVE LIGHTS FOR \ PARKING LOT ILLUMINATION \\\ v I I NOTES: ° A\ �\ \ i� �� 23 _ I \� IN TALL NE \ 1 1. ALL NEW WATER AND SEWER MAIN DESIGN AND PLANS WILL / \\ \ DRY U ITIES TO \\\\ \ I I I BE SUBMITTED AS INFRASTRUCTURE PLANS AND SHALL GO / B LOIN G 30 \ \ \\ \ CO NECTTO I THROUGH CITY ENGINEERING AND MDEQ REVIEW. \\ \ TRAM FORMER \p E STING / I I I I 2. INFRASTRUCTURE PLANS WILL BE SUBMITTED ON A \ FOR B ILDING 3 e\ OPPE AT i P1 STORAGE SERVI LP-1 I PARALLEL TRACT WITH SITEPLAN REVIEW. \ \\\ L-2-2I, BUILDING(2) I 3. ALL WATER METERS AND SHUT OFF VAVLES ARE LOCATED IN MECHNICAL ROOMS OF EACH BUILDING. EXISTINGMAIN / SEWER M IN qq \ �C`N To METERS ALL NEV1f' R \\ / \ ExISTJNG 4"D.I. GAS&POWER 4. CURBSTOPS AND CLEANOUTS SHALL BE LOCATED IN \\ \\\� d IRELIN 10'SETBACK ciz( UTILITIEISTO SIDEWALK AS SHOWN. ILDINGS 1&2 INSTALL 2-4"ELEC _ ___ ———————— 5. ALL UTILITY EASEMENTS WILL BE DRAFTED AND EXECUTED �V A\ �w 5� v�wv �� CONDUITS-TCOVER TRANSFORMER SIMULTANEOUSLY WITH SITE PLAN APPROVAL. v O� v� �_ 3 D FOR BUILDINGS 1&2 L=j — \ �� —�� ( INSTALL NEW INSTALL NEW_4PVC SFW€R _ \\ \ \\ w ——— —— —— -— ——— 4.5"COPPER — \ Su S PEEF�E WATER SERVICE \ ���$$$ uwaov SS LEGEND NEWCOB 15"RCP 15" P 7 STALL NEW Su V �A\ \V f COM.ACCESS 4"D.I.FIRE �V A ,i05TING 8" 0 - 8"PVC SERVICE �\ D I.wATER LARAMIESDR-37'TBC TOSTBC S S�I S S ------T------ TELEPHONE OR COMMUNICATIONS ' ExIsrlNc 8" ------G------ BURIED GAS �\ W H W W SEWER MAIN W W W W T =_------ -- ---- ---- v--I--- ------E------- BURIED ELECTRICAL / �\ � ��� ? -----__ -- - -- --fxlsrlN�:r --z = GRAPHIC scAr.x —_ _ _ _ WATER T o / 4o q 10 20 1 ----OVH----- OVER HEAD POWER / / � ---- - - - (1N FEET) ------W------ WATER MAIN ---—- nch ------S------- SEWER MAIN / 11 XI7 20 1L VERIFY SCALE REVISIONS DRAWN BY:CMW PROJECT NUMBER THESE PRINTS MAY BE NO. DESCRIPTION DATE BY CHK'D.BY:CMW CURRENT LANDING,LLC OFFICES&OUTDOOR REC FACILITIES 1154.004 REDUCED.L1NE BELOW NCH ON CHRISTOPHER APPR.BY: MT Q16 LOT 2,BILK 1 -PARKWAY PLAZA SUB SHEET NUMBER MEASURES ONE I e ORIGINAL DRAWING. Erlglnee.R BOZEMAN Des gng N.1 Ave. PE = Bozeze man,MTT 59715 'ttt DATE:2/5/23 DRAWING NUMBER NESIS MODIFY SCALE ACCORDINGLY g Phon.:(406)581-3319 e E ` Plannin q u Q.A.REVIEW NGINEERING, INC ms,`GHSTe"�cBY, CIVIL-UTILITIES C-2 HM 154\004\ACAD\SHEETS\SHEET-C-2-UTILITIES.dwg Plotted by Chris wasia on 10/2/2023 5:16 PM -'ht® inns OtAinnimA o a Xew StaaardofCommitment COPYRIGHT®GENESIS ENGINEERING,INC.2023 ONAI DATE: