HomeMy WebLinkAbout001 - A0-1 Cover Sheet1 View Name
1/8" = 1'-0"SCALE
101A
5
A3-8
3
A5-2
A
0
0
Room name
101
BUILDING SECTIONS
SEE DRAWINGS
EX: SHEET A3-8, DETAIL 5
WALL SECTIONS
SEE DRAWINGS
EX: SHEET A5-2, DETAIL 3
EXTERIOR ELEVATION
SEE DRAWINGS
EX: SHEET A7-1, DETAIL 4
CONSTRUCTION DETAIL
SEE DRAWINGS
EX: SHEET A6-3, DETAIL 2
INTERIOR ELEVATION
SEE DRAWINGS
EX: SHEET A7-1, DETAIL 4 & 5
DOOR SYMBOL
SEE DOOR SCHEDULE
WINDOW SYMBOL
SEE WINDOW TYPES
ROOM SYMBOL
EX: 202 - SECOND FLOOR
GRID LINES:
LETTERS LEFT TO RIGHT
NUMBERS BOTTOM TO TOP
WALL/PARTITION TYPE SYMBOL
SEE WALL/PARTITION TYPES
BENCHMARK
REFERENCE SYMBOLS
sE2
5
A3-8
1
A101
SIM
A7-14
A7-14
5
A
1
Name
Elevation
THESE DRAWINGS WERE PREPARED BY HIP AND HUMBLE
ARCHITECTURE, LLC. FOR CONSTRUCTION OF THE BUILDING
DESCRIBED. AS SUCH, THEY ARE THE PROPERTY OF HIP AND
HUMBLE ARCHITECTURE, LLC. AND MAY NOT BE REPRODUCED,
COPIED OR USED IN ANY WAY WITHOUT PRIOR APPROVAL FROM
HIP AND HUMBLE ARCHITECTURE, LLC.
REQUIRED STRUCTURAL TESTS & SPECIAL INSPECTIONS
IN ADDITION TO REGULAR INSPECTIONS, THE FOLLOWING
ITEMS WILL ALSO REQUIRE STRUCTURAL TESTS & SPECIAL
INSPECTIONS IN ACCORDANCE WITH CHAPTER 17 OF THE 2006
INTERNATIONAL BUILDING CODE:
SPECIAL INSPECTIONS: (SECTION 1704)
INSPECTION OF FABRICATORS (1704.2)
STEEL CONSTRUCTION (1704.3)
CONCRETE CONSTRUCTION (1704.4)
MASONRY CONSTRUCTION (1704.5)
WOOD CONSTRUCTION (1704.6)
SOILS (1704.7)
PILE FOUNDATIONS (1704.8)
PIER FOUNDATIONS (1704.9)
SPRAYED FIRE-RESISTANT MATERIALS(1704.10)
MASTIC & INTUMESCENT FIRE-RESISTANT COATINGS (1704.11)
EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) (1704.12)
SPECIAL CASES (1704.13)
SPECIAL INSPECTION FOR SMOKE CONTROL (1704.14)
STATEMENT OF SPECIAL INSPECTIONS: (SECTION 1705)
CONTRACTOR RESPONSIBILITY (1706)
SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE: (SECTION 1707)
STRUCTURAL STEEL (1707.2)
STRUCTURAL WOOD (1707.3)
COLD-FORMED STEEL FRAMING (1707.4)
PIER FOUNDATIONS (1707.5)
STORAGE RACKS AND ACCESS FLOORS (1707.6)
ARCHITECTURAL COMPONENTS (1707.7)
MECHANICAL AND ELECTRICAL COMPONENTS (1707.8)
DESIGNATED SEISMIC SYSTEMS VERIFICATION (1707.9)
SEISMIC ISOLATION SYSTEM (1707.10)
STRUCTURAL TESTING FOR SEISMIC RESISTANCE: (SECTION 1708)
REINFORCING & PRESTRESSING STEEL (1708.3)
STRUCTURAL STEEL (1708.4)
MECHANICAL AND ELECTRICAL EQUIPMENT (1708.5)
SEISMICALLY ISOLATED STRUCTURES (1708.6)
PROJECT SPECIFIC NOTES
1. DIMENSIONS ARE SHOWN ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.
2. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NEW MATERIALS
(UNO) & QUALIFIED CRAFTPERSONS TO COMPLETE THE WORK.
3. CONSTRUCTION DOCUMENTS SHOW THE DESIGN INTENT OF THE PROJECT &
MAY NOT SHOW MINOR DETAILS OF PROPOSED INSTALLATION. THE INCLUSION
OF THESE MINOR DETAILS IS IMPLIED TO PROVIDE A COMPLETE PROJECT & ARE
TO BE INCLUDED AS A PART OF A BID.
4. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF FINISHED FLOOR (AFF)
UNLESS NOTED OTHERWISE.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT EXISTING CONDITIONS
PRIOR TO PROCEEDING WITH EACH INSTALLATION OR PART OF THE WORK.
DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING.
6. THE CONTRACTOR IS TO COORDINATE THE INSTALLATION OF MATERIALS &
WORK OF OTHERS WHO ARE NOT SUB-CONTRACTORS TO THE GC, YET ARE
REQUIRED IN PROVIDING A COMPLETED PROJECT. AREAS OF WORK REQUIRING
COORDINATION INCLUDE BUT ARE NOT LIMITED TO THOSE INDICATED AS NIC ON
THE CONSTRUCTION DOCUMENTS.
7. REFER TO STRUCTURAL, MECHANICAL & ELECTRICAL DRAWINGS FOR
COORDINATION OF WORK.
8. ALL DIMENSIONS ARE FROM FACE OF STUD UNLESS NOTED OTHERWISE. THE
CONTRACTOR SHALL VERIFY ALL DIMENSION CONDITIONS PRIOR TO
CONSTRUCTION.
9. IN THE CASE OF CONTRADICTIONS BETWEEN DRAWINGS OR BETWEEN
DRAWINGS & SPECIFICATIONS, ASSUME THE MORE COSTLY APPROACH FOR
BIDDING PURPOSES. BRING ALL CONTRADICTIONS TO THE ATTENTION OF THE
ARCHITECT
10. THE CONSTRUCTION DOCUMENTS CONSIST OF THE CONSTRUCTION
DRAWINGS & SPECIFICATIONS INCLUSIVELY. SOME ITEMS MAY BE SHOWN ONLY
ON THE DRAWINGS OR INDICATED ONLY IN THE SPECIFICATIONS. FOR EXAMPLE,
THE SPECIFICATIONS MAY SAY TO PAINT ALL EXPOSED STRUCTURAL STEEL,
BUT THIS WILL NOT BE CALLED OUT ON ALL OF THE DRAWINGS.
11. 3-D VIEWS MAY BE USED THROUGHOUT THE CONSTRUCTION DOCUMENTS. 3-
D VIEWS ARE SHOWN TO CLARIFY CONDITIONS THAT CANNOT BE SHOWN IN
OTHER VIEWS. 3-D VIEWS MAY NOT SHOW ALL DETAILS REQUIRED TO
COMPLETE THE AREA. REFER TO DETAILS AT ADJACENT AREAS AS NECESSARY
OR ASK THE ARCHITECT PRIOR TO BIDDING.
THIS PROJECT SHALL COMPLY WITH THESE CODES, OR LATER
EDITIONS AS REQUIRED BY THE CITY OF BOZEMAN. CONFIRM
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 UNIFORM PLUMBING CODE
2020 NATIONAL ELECTRIC CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
NO HAZARDOUS MATERIALS EXCEEDING THE LIMITS STATED IN
THE 2021 INTERNATIONAL BUILDING CODE TABLES 414.2.4 &
414.5.1 WILL BE STORED IN THIS BUILDING.
CODE REQUIREMENTS
YET TO BE DETERMINED IF THESE BUILDINGS ARE TO BE
EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM IN
ACCORDANCE WITH APPLICABLE CODES.HIP AND HUMBLE ARCHITECTURE, LLC COPYRIGHT 2019418 South 5th Avenue
Bozeman, MT 59715
406.581.3832
Bob@hahaarchitect.com
PROJECT #:REVDESCDATEPHASEPRESDDDCDDATE1234HIP AND HUMBLE
ARCHITECTURE, LLC
A0-1
06.08.23COVER SHEETCURRENT LANDING, LLCOUTDOOR REC. FACILITYLOT 2 - PARKWAY PLAZAMASTER SITE PLAN2021------------CURRENT LANDING OFFICE BUILDING
BOZEMAN, MT
PHASE: MASTER SITE PLAN
DATE: 02.04.23
PROJECT TEAM
OWNER
CURRENT LANDING, LLC
P.O. BOX 1552
BOZEMAN, MT 59715
406.763.4465
CONTACT: BILL ZELL
ARCHITECTURAL
HIP AND HUMBLE ARCHITECTURE
418 SOUTH 5th AVENUE
BOZEMAN, MT 59715
406.581.3832
CONTACT: BOB MECHELS
STRUCTURAL MECHANICAL ELECTRICAL
SX-X XXXXXX
STRUCTURAL
MX-X XXXXXX
MECHANICAL
PX-X XXXXXX
PLUMBING
EX-X XXXXXX
ELECTRICAL
ARCHITECTURAL
A0-1 COVER SHEET
A2-1 SITE PLAN & PHASE INFORMATION
A3-1 FLOOR PLANS - PHASE 1 OFFICE BUILDING
A3-2 FIRST FLOOR PLAN - PHASE 2 OFFICE
A3-3 2ND FLOOR PH. 2 OFFICE - 1ST FLOOR PH. 1 STORAGE
A3-4 ROOF PLANS
A4-0 3D VIEWS
A4-1 EXTERIOR ELEVATIONS - PHASE 1 OFFICE BLDG
A4-2 EXTERIOR ELEVATIONS - PHASE 1 OFFICE BUILDING
A4-3 EXTERIOR ELEVATIONS - PHASE 1 STORAGE BUILDING
A4-4 EXTERIOR ELEVATIONS - PHASE 2 OFFICE BLDG
A4-5 EXTERIOR ELEVATIONS - PHASE 2 OFFICE BLDG
A5-1 BUILDING SECTIONS
SHEET INDEX
PROJECT INFORMATION
CODE INFORMATION:
- ZONING: BP (BUSINESS PARK)
- PERMITTED USES: RETAIL 0-5000 SF, RETAIL SALES 20% MAX., GENERAL SERVICE
ESTABLISHMENTS (INCL. GENERAL OFFICE SPACE), INDUSTRIAL AND WHOLESALE.
- MIN. LOT SIZE = 43,560SF (59,754 SF OR 1.372 ACRES PROVIDED)
- MIN. LOT WIDTH = 150' (APPROX. 267' X 234' PROVIDED)
- MAX. LOT COVERAGE = 60% (12.2% PROPOSED INCL. FUTURE)
- MAX. FLOOR AREA RATIO = 0.50 (0.19 PROPOSED INCL. FUTURE)
- MAX. BUILDING HEIGHT = 44' W/ ROOF SLOPE > 3/12 (PROPOSED BUILDING HEIGHTS; PH. 2
BLDG = 33'-1", 32' TO TOP OF BUS; PH. 1 BLDG = 31'-3"; STORAGE BLDG = 24'-10")
SETBACK INFORMATION:
- REAR = 20' MIN.
- SIDE = 15' MIN.
- ALLEY = 5' MIN.
- FRONT = SEE BLOCK FRONTAGE STANDARDS 38.510
ENTRANCE FACE A STREET, 60% OF FACADE TO BE GLAZING FROM 30" TO 10'
ABOVE GRADE, PARKING TO BE ON SIDE OR REAR OF BUILDING, SIDEWALK MIN. 12'
FROM CURB TO STOREFRONT, PARKING IN MULTI-BUILDING DEVELOPMENTS TO BE
50% OF STREET FRONTAGE MAX.
1 of 3 BOUNDARY INFORMATION
CIVIL / SURVEY
2 of 3 TOPOGRAPHICAL INFORMATION
3 of 3 AERIAL PHOTOGRAPH OVERLAY
SURVEY / CIVIL
MERIDIAN LAND SURVEY
610 PROFESSIONAL DR. STE. 3
BOZEMAN, MT 59718
PHONE: 406-624-6565
CONTACT: MICHAEL LAPP
GENESIS ENGINEERING
204 N. 11TH AVE.
BOZEMAN, MT 59715
PHONE: 406-581-3319
CONTACT: CHRIS WASIA
C-1 CIVIL - LAYOUT
C-2 CIVIL - UTILITIES
C-3 CIVIL - GRADING & DRAINAGE
C-4 CIVIL - DETAILS
C-5 CIVIL - DETAILS
VICINITY MAP
JOHNSON STRUCTURAL ENG.
440 N. GRAN AVENUE
BOZEMAN, MT 59715
406.5852939
CONTACT: LARRY JOHNSON
LEGAL DESCRIPTION:
- LOT 2, BLOCK 1 OF THE PARKWAY PLAZA SUBDIVISION AND
COMMERCIAL P.U.D.
ADA CERTIFICATION:
- THIS SITE HAS BEEN DESIGNED TO MEET ADA STANDARDS. SITE
CERTIFICATION IS ON SHEET C-1 IN THE UPPER LEFT CORNER.
- BUILDING ADA CERTIFICATION WILL BE SUBMITTED ON THE CITY
OF BOZEMAN STANDARD ACCESSIBILITY DISCLAIMER AS REQUIRED
FOR EACH INDIVIDUAL BUILDING.