083_CP3.0 - Plumbing Schedules
NOTES: 1.FIXTURES INDICATED AS ADA MUST COMPLY WITH ICC/ANSI A117.1. VERIFY EXACT NUMBERS, FIXTURES, DESIGNATIONS, LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS WITH ARCHITECTURAL PLANS. 2.ALL HW PIPING AND DRAIN LINES BENEATH ADA COMPLIANT LAVATORIES MUST BE INSULATED TO PREVENT BURNS. REF ARCHITECTURAL PLANS. INSULATE WITH MOLDED CLOSED CELL VINYL INSULATION -TRUEBRO OR EQUAL. 3.ALL ACCESS PANELS AND WALL BOXES SHALL BE RATED TO MATCH ASSEMBLY RATING. EQUIVALENT MANUFACTURERS: ENAMEL CAST IRON, VITREOUS CHINA, ACRYLIC: KOHLER, AMERICAN STANDARD, ELJER, CRANE, ZURN WARE, BEST BATH,LASCO, AQUAGLASS STAINLESS STEEL SINKS: ELKAY, JUST, DAYTON, KOHLER SERVICE SINKS: FIAT, BRADLEY, ACORN, STERN & WILLIAMS, E.L. MUSTEE FAUCETS: DELTA HDF, ELKAY, JUST, KOHLER, ZURN, AMERICAN STANDARD SHOWER VALVES, MIXING VALVES: POWERS, LEONARD, SYMMONS, MOEN TOILET SEATS: CHURCH, OSLONITE, BEMIS, SMITH ROOF DRAINS, FLOOR SINKS, FLOOR DRAINS, AND TRAPS: WATTS, ZURN, WADE, JOSAM WATTS BACKFLOW PREVENTION DEVICES, PRESSURE REDUCING VALVES: WILKENS, FEBCO, APOLLO/CONBRA CO TRAP PRIMERS AND SHOCK ABSORBERS: PPP, SIOUX CHEIF, SMITH ALTERNATE MANUFACTURERS: AO SMITH, BRADFORD WHITE, RHEEM/RUDD, STATE, LOCHINVAR NOTES: 1.PROVIDE WITH 3 YEAR WARRANTY AND 1 YEAR PARTS WARRANTY. 2.SIZE INTAKE AND EXHAUST PER MANUFACTURER'S RECOMMENDATIONS. ALTERNATE MANUFACTURERS: AO SMITH, BRADFORD WHITE, RHEEM/RUDD, STATE NOTES: 1.PROVIDE WITH 10 YEAR WARRANTY AND 1 YEAR PARTS WARRANTY. ALTERNATE MANUFACTURERS: B & G, GRUNDFOS, TACO NOTES: 1.PROVIDE ALL ANCILLARY COMPONENTS REQUIRED FOR A FULL INSTALLATION. WATER CALCULATIONS (Based on 2021 UPC Code) 23MIN02 - Lumberyard Flats Clubhouse CODE FIXTURE UNITS PER FIXTURE (COLD WATER) WATER CALC # OF FIXTURES MIN. FIXTURE BRANCH PIPE SIZE PRIVATE PUBLIC ASSEMBLY TOTAL FIXTURE UNITS FIXTURE bathtub or comb bath/shower (Pet Tub)private 0.0 1/2" 4.0 0.0 public 1.0 4.0 4.0 drinking fountain or water cooler public 0.0 1/2" 0.5 0.0 public 2.0 0.5 1.0 hose bibb private 0.0 1/2" 2.5 0.0 public 2.0 2.5 5.0 additional hose bibb private 0.0 1/2" 1.0 0.0 public 2.0 1.0 2.0 lavatory private 0.0 1/2" 1.0 0.0 public 4.0 1.0 4.0 Sinks: kitchen, domestic private 0.0 1/2" 1.5 0.0 public 1.0 1.5 1.5 Sinks: service or mop basin private 0.0 1/2" 1.5 0.0 public 1.0 3.0 3.0 water closet, greater than 1.6 gpf flushometer valve private 0.0 1" 7.0 0.0 public 4.0 8.0 32.0 TOTAL FIXTURE UNITS 52.5 GPM 53 INCOMING LINE SIZE 2" STREET PRESSURE 75 PSI LOSS THROUGH METER 5 PSI LOSS THROUGH BACKFLOW 10 PSI PRESSURE AT BUILDING 60 PSi PRESSURE AFTER ANY REQUIRED BOOSTING 60 PSI HIGHEST FIX IN FT 4 2 PSI PIPE LENGTH 270 L.F. FITTING LOSS 15 % PIPE LENGTH WITH FITTING LOSS 311 EQ. FT. LOSS THROUGH WATER SOFTENER 0 PSI ADDITIONAL LOSS 0 PSI REQUIRED PRESSURE FOR FARTHEST FIXTURE 20 PSI (20 psi flushvalve, 8 psi gravity) REMAINING PRESSURE 38 PSI PSI / 100 FT 12.33 NOTE: anticipated water meter size may vary as long as pressure loss through water meter does not exceed 5 psi WATER CALCULATIONS (Based on 2021 UPC Code) 23MIN02 - Lumberyard Flats Clubhouse CODE FIXTURE UNITS PER FIXTURE (COLD WATER) WATER CALC # OF FIXTURES MIN. FIXTURE BRANCH PIPE SIZE PRIVATE PUBLIC ASSEMBLY TOTAL FIXTURE UNITS FIXTURE bathtub or comb bath/shower (Pet Tub) private 0.0 1/2"4.0 0.0 public 1.0 4.0 4.0 drinking fountain or water cooler public 0.0 1/2" 0.5 0.0 public 2.0 0.5 1.0 hose bibb private 0.0 1/2" 2.5 0.0 public 2.0 2.5 5.0 additional hose bibb private 0.0 1/2" 1.0 0.0 public 2.0 1.0 2.0 lavatory private 0.0 1/2" 1.0 0.0 public 4.0 1.0 4.0 Sinks: kitchen, domestic private 0.0 1/2" 1.5 0.0 public 1.0 1.5 1.5 Sinks: service or mop basin private 0.0 1/2" 1.5 0.0 public 1.0 3.0 3.0 water closet, greater than 1.6 gpf flushometer valve private 0.0 1" 7.0 0.0 public 4.0 8.0 32.0 TOTAL FIXTURE UNITS 52.5 GPM 53 INCOMING LINE SIZE 2" STREET PRESSURE 75 PSI LOSS THROUGH METER 5 PSI LOSS THROUGH BACKFLOW 10 PSI PRESSURE AT BUILDING 60 PSi PRESSURE AFTER ANY REQUIRED BOOSTING 60 PSI HIGHEST FIX IN FT 4 2 PSI PIPE LENGTH 270 L.F. FITTING LOSS 15 % PIPE LENGTH WITH FITTING LOSS 311 EQ. FT. LOSS THROUGH WATER SOFTENER 0 PSI ADDITIONAL LOSS 0 PSI REQUIRED PRESSURE FOR FARTHEST FIXTURE 20 PSI (20 psi flushvalve, 8 psi gravity) REMAINING PRESSURE 38 PSI PSI / 100 FT 12.33 NOTE: anticipated water meter size may vary as long as pressure loss through water meter does not exceed 5 psi WASTE CALCULATIONS (Based on 2021 Uniform Plumbing Code) 23MIN02 - Lumberyard Flats Clubhouse CODE FIXTURE UNITS PER FIXTURE WASTE CALC # OF FIXTURES MIN. TRAP & TRAP ARM SIZE PRIVATE PUBLIC ASSEMBLY TOTAL FIXTURE UNITS FIXTURE bathtub or combination bath/shower private 0.0 1-1/2" 2.0 0.0 public 1.0 1-1/2" 2.0 2.0 drinking fountain, watercooler private 0.0 1-1/4" 0.5 0.0 public 1.0 1-1/4" 0.5 0.5 lavatory private 0.0 1-1/4" 1.0 0.0 public 4.0 1-1/4" 1.0 4.0 sink, kitchen, domestic (with or without food waste grinder, diswasher, or both) private 0.0 1-1/2" 2.0 0.0 public 1.0 1-1/2" 2.0 2.0 sink, service or mop basin, 3" trap arm public 1.0 3" 3.0 3.0 water closet, 1.6 gpf flushometer valve private 0.0 3" 3.0 0.0 public 4.0 3" 4.0 16.0 other 0.0 1-1/4" 1.0 0.0 0.0 1-1/2" 3.0 0.0 0.0 2" 4.0 0.0 0.0 3" 6.0 0.0 0.0 4" 8.0 0.0 TOTAL FIXTURE UNITS 27.5 EXITING WASTE SIZE 6" SLOPE 1/8" ALENGIN EERNOISSEFORP FOET A TS I D A HO16594 NSE D ECIL AAR O N M .P R O U GHPROJECT # SHEET NUMBERREVISION:DATE 618 N. Wallace Ave. | Bozeman 59715This drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above. Consultant:971-319-6249 | www.minarikarch.comProject Status:© 2021 MINARIK Architecture, Inc ALL RIGHTS RESERVED These Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission. 10/06/2023 Phone:208.288.2181 Project:22MIN0111/10/2023 12:48:57 PM2303 CP3.0The Lumberyard Flats - ClubhouseVirga Venture 1 LLCTschache LaneBozeman, MTIssue Date PLUMBING SCHEDULESSchematic DesignPLUMBING FIXTURE SCHEDULE FIXTURE NO. DESCRIPTION MANUFACTURER & MODEL SIZE PIPING CONNECTIONS FEATURES & ACCESSORIESTRAP WASTE VENT C.W. H.W. BFP-1 REDUCED PRESSURE BACKFLOW PREVENTER WATTS LF009-QT-S LINE SIZE - - - LINE SIZE - PROVIDE WITH 1/4 TURN BALL VALVE AND STRAINER. PROVIDE MANUFACTURER'S AIR GAP FITTING AS REQUIRED. BFP-2 REDUCED PRESSURE BACKFLOW PREVENTER (IRRIGATION) WATTS LF009-QT-S LINE SIZE - - - LINE SIZE - PROVIDE WITH 1/4 TURN BALL VALVE AND STRAINER. PROVIDE MANUFACTURER'S AIR GAP FITTING AS REQUIRED. EWC-1 ELECTRIC WATER COOLER (ADA COMPLIANT HI-LO) ELKAY EZSTL8WSK W/PUSH BUTTON ACTIVATION 18-3/8"x19" EACH 1-1/4"x1-1/2 " 1-1/2" 1-1/2" 1/2" - BARRIER FREE BI-LEVEL ELECTRIC WATER COOLER, HIGH POLISHED STAINLESS STEEL DRINKING FOUNTAINS WITH BUBBLER HEADS, PUSH BUTTONS, WASTE STRAINERS, MATCHING BACK PANEL, ACCESS PANEL, VANDAL RESISTANT BOTTOM PLATES, AND COMPLETE MOUNTING SYSTEM. PROVIDE WITH EZH20 BOTTLE FILLING STATION. 115/1/60, 5.0 FLA, 370 RATED WATTS. DELIVERS 8.0 GAL CHILLED WATER PER HOUR. MOUNT PER ADA REQUIREMENTS. FCO-1 FLOOR CLEANOUT (FINISHED FLOOR) JAY R SMITH SERIES 4020S LINE SIZE (SEE PLANS) - - - - - ROUND, MEDIUM DUTY FINISHED FLOOR CLEANOUT. PROVIDE WITH ROUND ADJUSTABLE NICKEL BRONZE TOP, GASKET SEAL, & TAPERED ABS PLUG. 2" MINIMUM. FD-1 FLOOR DRAIN JAY R SMITH 2005Y--A05-NB 2"/3" 2"/3" 2" TRAP PRIME R - ROUND NICKEL BRONZE STRAINER; PROVIDE WATERLESS TRAP SEAL, SURESEAL, OR APPROVED EQUAL. FS-1 FLOOR SINK JAY R SMITH 3440Y--C-P-12 12"x12" 10" DEEP 2"/3" 2"/3" 2" TRAP PRIME R - ACID RESISTANT COATED CAST IRON, 12" SQUARE, 10" DEEP WITH A. R. COATED CAST IRON STRAINER, NO-HUB OUTLET, HALF GRATE COVER. PROVIDE WATERLESS TRAP SEAL, SURESEAL, OR APPROVED EQUAL. GCO-1 GRADE CLEANOUT JAY R. SMITH 4220S LINE SIZE (SEE PLANS) - - - - - CAST IRON TOP, ABS PLUG WITH GASKET SEAL. SIZE TO MATCH WASTE PIPING. HB-1 HOSE BIBB (FREEZE-PROOF) WOODFORD 67 - - - 3/4" - ANTI-SIPHON, AUTOMATIC DRAINING WITH ONE REMOVABLE OPERATING KEY TO BE FURNISHED WITH EACH HYDRANT. FLUSH MOUNT AT 18" ABOVE FINISHED GRADE. L-1 LAVATORY-PUBLIC (COUNTER MOUNT, ADA COMPLIANT) KOHLER K-2196-4 W/MOEN L4621 FAUCET 20"x17" 1-1/4" 1-1/2" 1-1/2" 1/2" 1/2" VITREOUS CHINA, OVAL COUNTERTOP; 0.5 GPM VANDAL RESISTANT AERATOR. PROVIDE WITH K-8999 TRAP AND K-7131-A OFFSET GRID DRAIN ASSEMBLY FOR WHEELCHAIR. PROVIDE 1/2" X 3/8" ANGLE STOPS. PROVIDE WITH WATTS LFMMV THERMOSTATIC MIXING VALVE. SET MIXING VALVE TEMP. PER THE CURRENT ADOPTED VERSION OF THE ADA STANDARDS, PLUMBING CODE, AND LOCAL AHJ. PROVIDE ADA INSULATION KIT. S-1 SINK (SINGLE COMPARTMENT, SELF RIM COUNTERTOP, ADA COMPLIANT) ELKAY CELEBRITY GECR-2521 W/DELTA 100LF-WF FAUCET 25"x21"x 5-3/8" 1-1/2" 2" 1-1/2" 1/2" 1/2" 20 GAUGE STAINLESS STEEL; PUNCHED TO ACCOMMODATE FAUCET. 1/2" x 3/8" ANGLE STOP WITH OVAL HANDLE AND FLEXIBLE RISERS; 17 GAUGE TRAP. ELKAY LKJ-35 DRAIN (REAR PUNCH); 17 GA. CONTINUOUS DRAIN ASSEMBLY. PROVIDE "PASCO" AIR GAP FITTING FOR DISHWASHER CONNECTION. PROVIDE WITH IN-SINK-ERATOR BADGER I DISPOSAL, WITH POWER CORD, 1/3 HP, 120V 1PH. OFFSET GRID DRAIN ASSEMBLY FOR WHEELCHAIR; PROVIDE ADA INSULATION KIT. PROVIDE WITH WALL CLEANOUT (WCO-1). SH-1 SHOWER LASCO 1363CM WITH MOEN 62320 PRESS. BALANCED VALVE 36"x36"x 73-1/4"H 2" 2" 1-1/2" 1/2" 1/2" GELCOAT WITH INTEGRAL DRAIN; PROVIDE 2.5 GPM FLOW RESTRICTOR. PROVIDE WITH SHOWER CURTAIN, MOEN 3901 HEAD, ARM AND FLANGE. PLUMBING CONTRACTOR TO PROVIDE SAND/GROUT SHOWER PAN SUPPORT SH-2 SHOWER (ADA COMPLIANT) LASCO 6036-BFSC W/MOEN 8346 HAND HELD SHOWER SYSTEM 63"x34"x72"H 2" 2" 1-1/2" 1/2" 1/2" GELCOAT WITH INTEGRAL DRAIN; PROVIDE 2.5 GPM FLOW RESTRICTOR. PROVIDE MOEN 8346 SINGLE HANDLE PRESSURE BALANCING SHOWER VALVE WITH HAND HELD SHOWER SYSTEM, HOSE VACUUM BREAKER AND SLIDE BAR, SHOWER CURTAIN, FOLDING TEAKWOOD SEAT. PLUMBING CONTRACTOR TO PROVIDE SAND/GROUT SHOWER PAN SUPPORT AND REQUIRED GRAB BAR BLOCKING. SH-3 SHOWER (ADA COMPLIANT) LASCO 1483-TSTH W/MOEN 8346 HAND HELD SHOWER SYSTEM 48"x35"x73"H 2" 2" 1-1/2" 1/2" 1/2" GELCOAT WITH INTEGRAL DRAIN; PROVIDE 2.5 GPM FLOW RESTRICTOR. PROVIDE MOEN 8346 SINGLE HANDLE PRESSURE BALANCING SHOWER VALVE WITH HAND HELD SHOWER SYSTEM, HOSE VACUUM BREAKER AND SLIDE BAR, SHOWER CURTAIN, MOLDED SEAT. PROVIDE SAND/GROUT SHOWER PAN SUPPORT AND REQUIRED GRAB BAR BLOCKING. SS-1 SERVICE SINK FIAT MSB-2424 W/FIAT 830-AA FAUCET 24"x24"x12" 3" 3" 1-1/2" 1/2" 1/2" MOLDED STONE; FLOOR MOUNTED, SQUARE. INTEGRAL DRAIN. STOPS IN SHANK. CAST IRON TRAP.832-AA HOSE AND WALL HOOK, 889-CC STAINLESS STEEL MOP HANGER AND MSG-2424 STAINLESS STEEL SPLASH PANELS. PROVIDE WITH WALL CLEANOUT (WCO-1). WC-1 WATER CLOSET (PRESSURE ASSISTED TANK TYPE) KOHLER K-3505 SEAT K-4713 SUPPLY K-7637 ELONGATED BOWL - 3" 2" 1/2" - VITREOUS CHINA; FLOOR MOUNTED. PROVIDE VITREOUS CHINA TANK AND TANK COVER, POLISHED CHROME TRIP LEVER, BOLT CAPS, CLOSET SWEEP, SEAT FLANGE AND GASKET. OPEN FRONT SEAT, WHITE, WITHOUT COVER. PROVIDE 1/2"x3/8" ANGLE STOP WITH OVAL HANDLE AND FLEXIBLE RISERS. PROVIDE WITH MANUFACTURER'S PRESSURE ASSISTED FLUSHING SYSTEM. WC-2 WATER CLOSET (PRESSURE ASSISTED TANK TYPE, ADA COMPLIANT) KOHLER K-3493 SEAT K-4670C SUPPLY K-7637 ELONGATED BOWL - 3" 2" 1/2" - VITREOUS CHINA; FLOOR MOUNTED. PROVIDE VITREOUS CHINA TANK AND TANK COVER, POLISHED CHROME TRIP LEVER, BOLT CAPS, CLOSET SWEEP, SEAT FLANGE AND GASKET. OPEN FRONT SEAT, WHITE, WITHOUT COVER. PROVIDE 1/2" x 3/8" ANGLE STOP WITH OVAL HANDLE AND FLEXIBLE RISERS. PROVIDE WITH MANUFACTURER'S PRESSURE ASSISTED FLUSHING SYSTEM. MOUNT PER ADA; TRIP LEVER ON WIDE SIDE. WCO-1 WALL CLEANOUT JAY R. SMITH 4472 - - - - - TAPERED BRONZE PLUG AND STAINLESS STEEL COVER. SIZE TO MATCH WASTE PIPING, 2" MINIMUM. GAS FIRED WATER HEATER SCHEDULE EQUIPMENT NO.MANUFACTURER MODEL TYPE VOLUME (GAL) RECOVERY (GPH)FUEL INPUT (MBH) OUTPUT (MBH) FLUE SIZE VOLT/PH/CY WEIGHT NOTES INSTANTANEOUS ELECTRIC WATER HEATER EQUIPMENT NO.MANUFACTURER MODEL MINIMUM FLOW (GPM) MAXIMUM FLOW (GPM) ELECTRICAL NOTESVOLT/PH/CY AMPS KW PUMP SCHEDULE EQUIPMENT NO.AREA SERVED PUMP LOCATION STYLE/CONST. FLUID TYPE RPM FLOW RATE (GPM) HEAD (FT) INLET SIZE (INCH) DISCH SIZE (INCH) IMPELLER DIA (INCH) ELECTRIC WEIGHT MANUFACTURER MODEL NOTESHP VOLT.-PH.-CY.REVISIONDATEREASON FOR ISSUE