Loading...
HomeMy WebLinkAbout082_CP2.3 - Plumbing Water & Gas Plan - First FloorINSTALLATION REQUIREMENTS: 1. WATER SERVICE LINE INSTALLATIONS SHALL CONFORM TO THE REQUIREMENTS OF THE CITY OF BOZEMAN WATER SUPERINTENDANT. 2. SERVICE LINES SHALL BE TYPE K COPPER FOR 3/4", 1", 1-1/2", AND 2" SERVICES. SEE STANDARD DRAWING NO. 02660-12 FOR 4" AND LARGER DOMESTIC SERVICE LINES. SERVICE LINES BETWEEN 2" AND 4" ARE NOT ALLOWED. 3. STRAIGHT COPPER TUBING SHALL BE USED FOR 1-1/2" AND 2" SERVICES. 4. SERVICE LINES SHALL BE BEDDED 3" UNDER AND OVER THE PIPE WITH SAND. NATIVE MATERIAL MAY BE USED AS BEDDING IF IT CONFORMS TO THE REQUIREMENTS OF MONTANA PUBLIC WORKS STANDARD DRAWING 02221-2 AND DOES NOT CONTAIN ANY MATERIAL LARGER THAN 3/4". 5. PROVIDE FLEXIBLE, WATER TIGHT CONNECTION FOR ALL WALL OR FLOOR PIPE PENETRATIONS. 6. METERS SHALL BE INSTALLED BY THE CITY WATER DEPARTMENT AT CUSTOMERS' EXPENSE. 7. NO SERVICE LINE SHALL BE BACKFILLED UNTIL IT HAS BEN INSPECTED AND APPROVED BY THE WATER DEPARTMENT. 8. CONTACT CITY OF BOZEMAN WATER DEPARTMENT FOR APPROVED LIST OF COPPER CONNECTIONS. 9. WATER SERVICE LINE MAY BE REDUCED TO A SMALLER SIZE THAN THE WATER SERVICE STUB. REDUCTION MUST BE MADE WITHIN 18" OF CURB STOP. 10. METER, BACKFLOW PROTECTION, AND INCOMING SERVICE LINE MUST ALL BE THE SAME SIZE. DOWNSTREAM SHUTOFF TO DOMESTIC FIXTURES BACKFLOW PREVENTION ASSEMBLY (AS REQUIRED) METER ANGLE STOP 1' MIN./2' MAX1' MIN. FOUNDATION WALL QUARTER-BEND COUPLING (1-1/2" & 2" SERVICES ONLY) NOTE: METER SIZED SAME AS INCOMING LINE - NO EXCEPTIONS. 1 1 A A B B C C D D 2 2 6 6 5 5 4 4 3 3 4' - 10" 2BFP-1 2 P2.3 2" CW 1 3 Work Room 117 Work Room 118 JC 119 Co-Working Area 114 Work Room 116 Work Room 115 Conference Room 113 Lounge 112 Property Managment Office 110 View Room 109 Entry + Reception 101 Mailroom 103 Leasing Office 102 Staff Room 104 Oversize Packages 106 Package Lockers 105 Pet Wash 108 Maintenance and Storage 107 Pump Room 126 Fitness 125 Restroom 124 Restroom 123 Utility Room 121 West Entry / Cooridor 120 WH 142 P4.0 PT-1 WC-1WC-1 WC-1WC-1 L-1 L-1 SH-1 L-1 L-1 SH-1 BFP-2 5 P4.0 PLUMBING GENERAL NOTES: CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER-FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER-FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. CONTRACTOR TO VERIFY INVERTS OF MANHOLES AND DOCUMENT WHETHER BACKCHECK VALVE IS REQUIRED. PROVIDE ISOLATION VALVES ON ALL PLUMBING FIXTURES AND EQUIPMENT FOR SERVICE. PROVIDE PIPING INSULATION WITHIN BUILDING ENVELOPE, ON THE INTERIOR SIDE OF THE INSULATION. PROVIDE CLEANOUTS ON ALL BRANCH PIPING OVER 8' IN LENGTH AND CHANGES IN DIRECTION OF 135 DEGREES OR MORE. 1. 2. 3. 4. 5. 6. PLUMBING KEYNOTES: EXTEND 5'-0" FROM BUILDING AND CONNECT TO SITE UTILITIES. 2" CW SHALL RISE FROM BELOW SLAB. SEE 1/P4.0 FOR SPECIFIC BOZEMAN WATER ENTRY REQUIREMENTS. AFTER BUILDING BACKFLOW, TAP OFF 1-1/2" CW FOR IRRIGATION CONNECTION. PROVIDE BACKFLOW, BFP-2 AND ISOLATION VALVE IN ACCESSIBLE LOCATION. CAP FOR FUTURE CONNECTION. COORDINATE EXACT LOCATION WITH GENERAL CONTRACTOR PRIOR TO INSTALL. ROUTE 3/4" CW & HW DOWN TO WATER HEATER. ROUTE 3/4" CW DOWN IN WALL TO HOSE BIBB. PROVIDE WITH ACCESSIBLE ISOLATION VALVE. COORDINATE EXACT LOCATION WITH GENERAL CONTRACTOR PRIOR TO INSTALL. 1. 2. 3. 4. 5. # ALENGIN EERNOISSEFORP FOET A TS I D A HO16594 NSE D ECIL AAR O N M .P R O U GHPROJECT # SHEET NUMBERREVISION:DATE 618 N. Wallace Ave. | Bozeman 59715This drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above. Consultant:971-319-6249 | www.minarikarch.comProject Status:© 2021 MINARIK Architecture, Inc ALL RIGHTS RESERVED These Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission. 10/06/2023 Phone:208.288.2181 Project:22MIN0111/10/2023 12:48:54 PM2303 CP2.3The Lumberyard Flats - ClubhouseVirga Venture 1 LLCTschache LaneBozeman, MTIssue Date PLUMBING WATER & GAS PLAN - FIRST FLOORSchematic DesignSCALE: 1/8" = 1'-0" WATER AND GAS PLAN - FIRST FLOOR1 REVISIONDATEREASON FOR ISSUESCALE: NTS2BOZEMAN DOMESTIC WATER ENTRY (2" & SMALLER) DETAIL