Loading...
HomeMy WebLinkAbout079_P2.3 - Plumbing Water Plan - First FloorPRESSURE REDUCING VALVE BACKFLOW PREVENTION ASSY. SPOOLMETER & STRAINER SPOOL NO FITTINGS BETWEEN METER AND BACKFLOW PREVENTION. 90° BEND 1' MIN. TO INTERNAL WALL 2' MIN. TO EXTERNAL WALL 1' MIN. TO INTERNAL WALL2' MIN. TO EXTERNAL WALLAPPROX. 9'-4" [113"] SOV 2' MIN. CLEAR TO OTHER MECHANICAL LINES OS&Y VALVE INSTALL VALVE WITH STEM PARALLEL TO WALL NOTES: 1. A MINIMUM OF FOUR (4) PIPE DIAMETERS OF STRAIGHT RUN PIPE IS REQUIRED UPSTREAM AND DOWNSTREAM OF THE METER/STRAINER ASSEMBLY. 2. METER MUST BE INSTALLED HORIZONTAL. STRAINER IS REQUIRED. 3. BACKFLOW PREVENTION ASSEMBLIES MUST BE UL OR FM LISTED AND APPROVED BY USCFCCCHR. 4. ALL PIPE SHALL BE DUCTILE IRON UP TO PRESSURE REDUCING VALVE. PLAN VIEW 4" WATER SUPPLY (FROM SITE) 3" METER SIZE 3" WATER SUPPLY TO BUILDING 3121 3 Bed 416 Garage 246 Garage 247 Trash 415 Stair B 248 Bike/Ski 250 Garage 251 Garage 252 Garage 253 Garage 254 Garage 255 Garage 264 Garage 417 Garage 257 Riser 420 Lobby 419 2 Bed 2361 Bed 237 1 Bed 238 1 Bed 239 1 Bed 240 2 Bed 241 1 Bed 242 1 Bed 2433 Bed 244 9' - 4"3 BFP-1 2 P2.3 4 5 6 7 FP3 1 1/2" CW1 1/4" CW1 1/4" CW1 1/2" CW1 1/2" CW 1 1/2" CW 1 1/4" CW1 1/4" CW1 1/4" CW 1 1/4" CW 1 1/4" CW 1 1/2" CW 1 1/2" CW1 1/4" CW1 1/4" CW1 1/2" CW1 1/2" CW3" CW4" CW1 1/4" CW1 1/4" CW1 1/2" CW1 1/2" CW1 1/4" CW BFP-2 7 P4.0 3" CW3" CW 2 1/2" CW 2" CW2" CW2" CW 2 1/2" CW 2 1/2" CW 3" CWPLUMBING GENERAL NOTES: CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER-FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER-FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. CONTRACTOR TO VERIFY INVERTS OF MANHOLES AND DOCUMENT WHETHER BACKCHECK VALVE IS REQUIRED. PROVIDE ISOLATION VALVES ON ALL PLUMBING FIXTURES AND EQUIPMENT FOR SERVICE. PROVIDE PIPING INSULATION WITHIN BUILDING ENVELOPE, ON THE INTERIOR SIDE OF THE INSULATION. PROVIDE CLEANOUTS ON ALL BRANCH PIPING OVER 8' IN LENGTH AND CHANGES IN DIRECTION OF 135 DEGREES OR MORE. 1. 2. 3. 4. 5. 6. PLUMBING KEYNOTES: ROUTE 1" CW INTO UNIT. PROVIDE ISOLATION VALVE PRIOR TO ANY EQUIPMENT OR FIXTURE. SEE ENLARGED UNIT FOR CONTINUATION. ROUTE 1-1/4" CW RISER UP TO UNITS ABOVE. SEE 12/P4.0 FOR DETAIL. EXTEND 5'-0" FROM BUILDING AND CONNECT TO SITE UTILITIES. 4" CW SHALL RISE FROM BELOW SLAB 24" FROM EXTERIOR WALLS. BOTTOM OF RISER TO BE NO MORE THAN 24" AFF. PROVIDE FOR 24" CLEARANCE IN FRONT OF RISER AND 12" MIN. ON ENDS. LOCATE BUILDING SHUT-OFF AT THIS LOCATION. INSTALL WATER METER, BFP AND OTHER DEVICES REQUIRED BY THE WATER AUTHORITY IN HORIZONTAL CONFIGURATION. MAINTAIN 24" CLEAR BETWEEN METER/BFP ASSEMBLY AND FIRE SERVICE ASSEMBLY. REFER TO DETAIL 2/P4.2 FOR SPECIFIC BOZEMAN WATER ENTRY REQUIREMENTS. PLUMBING CONTRACTOR TO LOCATE PLUMBING EQUIPMENT AND VALVES BELOW STAIRS. ANY PIPING SHALL BE INSTALLED IN AS CLEAN A MANNER AS POSSIBLE. ROUTE ANY EXPOSED PIPING TIGHT AGAINST WALLS AND CEILINGS. COORDINATE WITH ARCHITECTURAL PLANS PRIOR TO INSTALLATION. AFTER BUILDING BACKFLOW, TAP OFF 1-1/2" CW FOR IRRIGATION CONNECTION. PROVIDE BACKFLOW BFP-2 AND ISOLATION VALVE IN ACCESSIBLE LOCATION. CAP FOR FUTURE CONNECTION. COORDINATE EXACT LOCATION WITH GENERAL CONTRACTOR PRIOR TO INSTALL. FIRE PROTECTION WATER LINE SHOWN FOR REFERENCE ONLY. COORDINATE WITH CIVIL AND FIRE PROTECTION DESIGN FOR SIZE, FINAL ROUTING, AND REQUIREMENTS. ROUTE 3/4" CW DOWN IN WALL TO HOSE BIBB. PROVIDE WITH ACCESSIBLE ISOLATION VALVE. COORDINATE EXACT LOCATION WITH GENERAL CONTRACTOR PRIOR TO INSTALL. 1. 2. 3. 4. 5. 6. 7. 8. # PROJECT # SHEET NUMBERREVISION:DATE 618 N. Wallace Ave. | Bozeman 59715This drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above. Consultant:971-319-6249 | www.minarikarch.comProject Status:© 2021 MINARIK Architecture, Inc ALL RIGHTS RESERVED These Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission. 10/06/2023 Phone:208.288.2181 Project:22MIN0111/10/2023 12:43:15 PM2303 P2.3The Lumberyard FlatsVirga Venture 1 LLCTschache Lane09/25/2023 PLUMBING WATER PLAN - FIRST FLOORSDSCALE: 1/8" = 1'-0" WATER PLAN - 1ST FLOOR1 REVISIONDATEREASON FOR ISSUESCALE: NTS2BOZEMAN REDUCED PRESSURE BACFLOW PREVENTER DETAIL