Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
066_A4.00 - Building Sections
Level 1 -T/Slab 0' -0" Level 2 -T/PLY 12' -0" Level 3 -T/PLY 22' -4" Grade -1' -0" Level 4 -T/PLY 32' -8" Roof -T/PLY 43' -0" T/Parapet 46' -0" F E D C B A 47' - 0"3' - 0"10' - 4"10' - 4"10' - 4"12' - 0"1' - 0"6' - 0"30' - 6"5' - 3"29' - 0"5' - 3" 76' - 0" Clear 5' - 4" 2 A4.00 Garage 2 Bed 2 Bed 2 BedCorridor Corridor Corridor Corridor1 Bed 1 Bed 1 Bed 1 Bed Verify. Typ, 6" Below t.o. conc fnd 1/8" 1'-0" Slope @ SE Garage Slope @ Accessible Garage Level 1 -T/Slab 0' -0" Level 2 -T/PLY 12' -0" Level 3 -T/PLY 22' -4" Grade -1' -0" Level 4 -T/PLY 32' -8" Roof -T/PLY 43' -0" T/Parapet 46' -0" 10987654321 1 A4.00 LobbyStair AGarageGarageGarageGarageGarageGarageGarageGarageBike/SkiStair BTrashGarageGarage3 Bed 3 Bed 3 Bed 3 Bed 2 Bed 2 Bed 2 Bed 2 Bed 2 Bed 2 Bed 2 Bed 2 Bed 2 Bed 1 Bed 1 Bed 1 Bed 1 Bed 1 Bed 1 Bed 1 Bed 1 Bed 1 Bed 34' - 0"24' - 0"24' - 0"36' - 0"24' - 0"24' - 0"24' - 0"24' - 0"18' - 6" 232' - 6"3' - 0"10' - 4"10' - 4"10' - 4"12' - 0"1' - 0"47' - 0"Stair A Stair B GENERAL NOTES 1. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR TO CONSTRUCTION; NOTIFY ARCHITECT OF ALL DISCREPANCIES. 2. CONTRACTOR TO VERIFY EXISTING UTILITY LOCATIONS PRIOR TO CONSTRUCTION. 3. DIMENSIONS ARE TO FACE OF FRAMING, FACE OF CONCRETE, GRIDLINE, OR CENTERLINE OF OBJECT, U.N.O. 4. DETAIL DRAWINGS OR LARGER SCALE DRAWINGS TAKE PRECEDENT OVER SMALLER SCALE DRAWINGS. 5. REFERENCE STRUCTURAL FOR SHEAR WALL LOCATIONS 6. INTERIOR PARTITION WALLS TO BE TYPE I-1, TYP, U.N.O. REFERENCE A0.1 FOR HORIZONTAL AND VERTICAL ASSEMBLIES 7. VERIFY ALL CLEARANCES/ROUGH OPENIGNS FOR APPLIANCES PLUMBING AND EQUIPMENT 8. PROVIDE BACKING OR STRAPPING FOR ALL WALL MOUNTED ACCESSORIES, FURNISHINGS, AND EQUIPMENT, VERIFY WEIGHTS AND LOCATIONS. 9. REFERENCE A0.2 FOR ACCESSIBILITY STANDARDS 1-Hour Rated Fire Partition per Section 708 1-Hour Rated Horizontal Assembly Per Section 711 2-Hour Rated Fire Barrier per Section 707 PROJECT # SHEET NUMBERREVISION:DATE 618 N Wallace | Bozeman, MT 59715This drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above. Consultant:971−319−6249 | www.minarikarch.comProject Status:© 2022 MINARIK Architecture, Inc ALL RIGHTS RESERVED These Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission.11/10/2023 3:27:03 PM2303 A4.00The Lumberyard FlatsVirga Venture 1 LLCTschache Lane11/10/2023 Building SectionsSchematic Design1/8" = 1'-0" Building Section - N/S1 1/8" = 1'-0" Building Section - E/W2 REVISIONDATEREASON FOR ISSUE