HomeMy WebLinkAbout053_A0.02 - Assemblies - Wall(2) layers 5/8" GWB Type X 2X Stud Wall, REF Structural R-13 MIN. Batt Insulation 2" Insulated Sheathing, R-7.5 min. Finished Surface @ E-2c Exterior Interior MTL-1 E-5 E-5b (1) layers 5/8" GWB Type X (1) layers 5/8" EXT Sheathing Type X E-5, E-5c: Fire-Rating: 1 HR, Interior Side only STC-Rating: Assembly: UL #V302 E-5d: Fire-Rating: 1 HR, Both Sides STC-Rating: Assembly: GA WP 8105 Integrated WRB Exterior Siding: E-4: PTD Panel-1 E-4c: WD-1 Integrated WRB R-13 MIN Batt Insulation InteriorExterior 2x WD Studs, REF Structural (2) layers 5/8" Type X GWB E-4 2" Insulated Sheathing, R-7.5 MIN 3/4" Furring Strip per MFR E-4b (1) layer 5/8" Type X GWB (1) layer 5/8" Type X EXT GWB Exterior Siding: E-4d: PTD Panel-1 E-4e: WD-1 E-4, E-4c: Fire-Rating: 1 HR, Interior Side only STC-Rating: Assembly: UL #V302 E-4d, E-4e: Fire-Rating: 1 HR, Both Sides STC-Rating: Assembly: GA WP 8105 E-2 ExteriorInterior NOTE: Planter walls to be poured separately from concrete stem walls or curbs Conc Curb, REF Structural, Smooth Finish Dampproofing InteriorExterior E-3 Location: LEVEL 1 STAIR CORE @ EXTERIOR WALL Fire-Rating: 2 HR Acoustic Test: NGC 3056 Assembly: GA WP 3820 I-3 Wall Assembly Exterior Siding E-3: MTL-1, no furring E-3b: WD-1 E-3c: PTD Panel-1 Integrated WRB 2" Insulated Sheathing, R-7.5 MIN 3/4" Furring Strip Double Row 2x4 Studs 16" O.C. w/ Separate Plates 1" Air Gap (2) 5/8" Type 'X' GWB EA Side PWD sheathing, where occurs, SSD R-13 MIN Batt Insulation E-3 InteriorInterior 2x4 WD FRAMING, 16" OC (I-1c: Use 2x6 WD Framing 16" O.C.) 5/8" GBD I-1 Single side 5/8" GWB at I-1b InteriorInterior I-3 (2HR STAIR CORE WALLS) Double Row 2x4 Studs 16" O.C. w/ Separate Plates 1" Air Gap (2) 5/8" Type 'X' GWB EA Side PWD sheathing, where occurs, REF Structural Batt Insulation I-3: Fire-Rating: 2 HR STC-Rating: 65-69 Assembly: GA WP 3725 Batt Insulation InteriorInterior-Corridor WD Framing, 16" OC (I-4b: Use 2x8 WD Framing, 16" OC) 2 Layers Type X 5/8" GBD I-4 (1HR, STC-53) Resilient Channel 1 Layer Type X 5/8" GBD PWD sheathing where occurs, REF Structural I-4, I-4b: Fire-Rating: 1 HR STC-Rating: 50-54 Assembly: GA WP 3245 Acoustic Insulation InteriorInterior-Corridor WD Framing, 16" OC 2 Layers 5/8" Type X GBD I-5 (2HR, STC-55-59) 2 Layers 5/8" Type X GBD PWD sheathing where occurs, REF Structural Resilient Channel I-5: Fire-Rating: 2 HR STC-Rating: 55-59 Assembly: GA WP 3809, 3825 Acoustic Insulation InteriorInterior 2x4 WD FRAMING, 16" OC 1/2" PWD finish I-2 InteriorInterior 2.5" MTL CH Stud, 20GA MIN I-6b: 6" MTL CH Stud 1" Type 'X' GWB I-6 (2HR) Location: CHASE Fire-Rating: 2 HR STC Rating: 50-54 Assembly: GA WP 7051 2 Layers 1/2" Type 'X' GWB Acoustic Insulation Exterior Interior Backfill, REF Geotech Report Dampproofing Conc. FND, REF Structural XPS Insulation, R-xxx Min, Continue to T.O. Footing PROJECT # SHEET NUMBERREVISION:DATE 618 N Wallace | Bozeman, MT 59715This drawing is not intended nor shall it be used for construction purposes unless the signed professional stamp of a regisered architect employed at MINARIK Architecture, Inc. is affixed above. Consultant:971−319−6249 | www.minarikarch.comProject Status:© 2022 MINARIK Architecture, Inc ALL RIGHTS RESERVED These Drawings are the Property of MINARIK Architecture, Inc and are not to be used or reproduced in any manner without prior written permission.11/10/2023 3:26:49 PM2303 A0.02The Lumberyard FlatsVirga Venture 1 LLCTschache Lane11/10/2023 Assemblies - WallSchematic Design1 1/2" = 1'-0" Exterior Wall Assembly - E511 1/2" = 1'-0" Exterior Wall Assembly - E421 1/2" = 1'-0" Planter Wall Assembly - E-24 1 1/2" = 1'-0" Exterior Wall Assembly - E-33 1 1/2" = 1'-0" Interior Wall Assembly - I-110 1 1/2" = 1'-0" Interior Wall Assembly - I-38 1 1/2" = 1'-0" Interior Wall Assembly - I-47 1 1/2" = 1'-0" Interior Wall Assembly - I-561 1/2" = 1'-0" Interior Wall Assembly - I-29 1 1/2" = 1'-0" Interior Wall Assembly - I-611 1 1/2" = 1'-0" Exterior Wall Assembly - E-15 GA Manual for 2 hour wd framed chase walls are all double walls, WP 5516 Proprietary -double stud, double layer of gyp both sides WP5520 Generic -same as above WP 5530 Generic -staggered stud, double layer of gyp both sides REVISIONDATEREASON FOR ISSUE