Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18_Fixture PL1
One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 1 of 10 COMMERCIAL OUTDOOR Ordering Information EXAMPLE: DSX1 LED P7 40K 70CRI T3M MVOLT SPA NLTAIR2 PIRHN DDBXD DSX1 LED Series LEDs Color temperature 2 Color Rendering Index 2 Distribution Voltage Mounting DSX1 LED Forward optics P1 P6 P2 P7 P3 P8 P4 P9 P5 Rotated optics P10 1 P12 1 P11 1 P13 1 (this section 70CRI only) 30K 3000K 40K 4000K 50K 5000K (this section 80CRI only, extended lead times apply) 27K 2700K 30K 3000K 35K 3500K 40K 4000K 50K 5000K 70CRI 70CRI 70CRI 80CRI 80CRI 80CRI 80CRI 80CRI AFR Automotive front row T1S Type I short T2M Type II medium T3M Type III medium T3LG Type III low glare 3 T4M Type IV medium T4LG Type IV low glare 3 TFTM Forward throw medium T5M Type V medium T5LG Type V low glare T5W Type V wide BLC3 Type III backlight control 3 BLC4 Type IV backlight control 3 LCCO Left corner cutoff 3 RCCO Right corner cutoff 3 MVOLT (120V-277V) 4 HVOLT (347V-480V) 5,6 XVOLT (277V - 480V) 7,8 120 16, 26 208 16, 26 240 16, 26 277 16, 26 347 16, 26 480 16, 26 Shipped included SPA Square pole mounting (#8 drilling) RPA Round pole mounting (#8 drilling) SPA5 Square pole mounting #5 drilling 9 RPA5 Round pole mounting #5 drilling 9 SPA8N Square narrow pole mounting #8 drilling WBA Wall bracket 10 MA Mast arm adapter (mounts on 2 3/8" OD horizontal tenon) Control options Other options Finish (required) Shipped installed NLTAIR2 PIRHN nLight AIR gen 2 enabled with bi-level motion / ambient sensor, 8-40’ mounting height, ambient sensor enabled at 2fc. 11, 12, 20, 21 PIR High/low, motion/ambient sensor, 8-40’ mounting height, ambient sensor enabled at 2fc 13, 20, 21 PER NEMA twist-lock receptacle only (controls ordered separate) 14 PER5 Five-pin receptacle only (controls ordered separate)14, 21 PER7 Seven-pin receptacle only (controls ordered separate) 14, 21 FAO Field adjustable output 15, 21 BL30 Bi-level switched dimming, 30% 16, 21 BL50 Bi-level switched dimming, 50% 16, 21 DMG 0-10v dimming wires pulled outside fixture (for use with an external control, ordered separately) 17 DS Dual switching 18, 19, 21 Shipped installed SPD20KV 20KV surge protection HS Houseside shield (black finish standard) 22 L90 Left rotated optics 1 R90 Right rotated optics 1 CCE Coastal Construction 23 HA 50°C ambient operation 24 BAA Buy America(n) Act Compliant SF Single fuse (120, 277, 347V) 26 DF Double fuse (208, 240, 480V) 26 Shipped separately EGSR External Glare Shield (reversible, field install required, matches housing finish) BSDB Bird Spikes (field install required) DDBXD Dark Bronze DBLXD Black DNAXD Natural Aluminum DWHXD White DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white D-Series Size 1LED Area Luminaire Catalog Number Notes Type Introduction The modern styling of the D-Series features a highly refined aesthetic that blends seamlessly with its environment. The D-Series offers the benefits of the latest in LED technology into a high performance, high efficacy, long-life luminaire. The photometric performance results in sites with excellent uniformity, greater pole spacing and lower power density. D-Series outstand- ing photometry aids in reducing the number of poles required in area lighting applications with typical energy savings of 65% and expected service life of over 100,000 hours. Hit the Tab key or mouse over the page to see all interactive elements. H2 L W H1 Specifications EPA:0.69 ft2 (0.06 m2) Length:32.71" (83.1 cm) Width:14.26"(36.2 cm) Height H1:7.88"(20.0 cm) Height H2:2.73"(6.9 cm) Weight:34 lbs(15.4 kg) One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 2 of 10 COMMERCIAL OUTDOOR Accessories Ordered and shipped separately. DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 25 DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 25 DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 25 DSHORT SBK Shorting cap 25 DSX1HS P# House-side shield (enter package number 1-13 in place of #) DSXRPA (FINISH) Round pole adapter (#8 drilling, specify finish) DSXSPA5 (FINISH) Square pole adapter #5 drilling (specify finish) DSXRPA5 (FINISH) Round pole adapter #5 drilling (specify finish) DSX1EGSR (FINISH) External glare shield (specify finish) DSX1BSDB (FINISH) Bird spike deterrent bracket (specify finish) Shield Accessories External Glare Shield (EGSR) Tenon O.D. Mounting Single Unit 2 @ 180 2 @ 90 3 @ 90 3 @120 4 @ 90 2-3/8"RPA AS3-5 190 AS3-5 280 AS3-5 290 AS3-5 390 AS3-5 320 AS3-5 490 2-7/8"RPA AST25-190 AST25-280 AST25-290 AST25-390 AST25-320 AST25-490 4"RPA AST35-190 AST35-280 AST35-290 AST35-390 AST35-320 AST35-490 Tenon Mounting SlipfitterDrilling Top of Pole 0.563" 2.650" 1.325"0.400"(2 PLCS) Template #8 Ordering Information NOTES 1 Rotated optics available with packages P10, P11, P12 and P13. Must be combined with option L90 or R90.2 30K, 40K, and 50K available in 70CRI and 80CRI. 27K and 35K only available with 80CRI. Contact Technical Support for other possible combinations. 3 T3LG, T4LG, BLC3, BLC4, LCCO, RCCO not available with option HS.4 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). 5 HVOLT driver operates on any line voltage from 347-480V (50/60 Hz).6 HVOLT not available with package P1 and P10 when combined with option NLTAIR2 PIRHN or option PIR. 7 XVOLT operates with any voltage between 277V and 480V (50/60 Hz).8 XVOLT not available in packages P1 or P10. XVOLT not available with fusing (SF or DF). 9 SPA5 and RPA5 for use with #5 drilling only (Not for use with #8 drilling).10 WBA cannot be combined with Type 5 distributions plus photocell (PER). 11 NLTAIR2 and PIRHN must be ordered together. For more information on nLight AIR2 visit this link12 NLTAIR2 PIRHN not available with other controls including PIR, PER, PER5, PER7, FAO, BL30, BL50, DMG and DS. NLTAIR2 PIRHN not available with P1 and P10 using HVOLT. NLTAIR2 PIRHN not available with P1 and P10 using XVOLT. 13 PIR not available with NLTAIR2 PIRHN, PER, PER5, PER7, FAO BL30, BL50, DMG and DS. PIR not available with P1 and P10 using HVOLT. PIR not avail-able with P1 and P10 using XVOLT.14 PER/PER5/PER7 not available with NLTAIR2 PIRHN, PIR, BL30, BL50, FAO, DMG and DS. Photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting Cap included.15 FAO not available with other dimming control options NLTAIR2 PIRHN, PIR, PER5, PER7, BL30, BL50, DMG and DS. 16 BL30 and BL50 are not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, FAO, DMG and DS. BL30 or BL50 must specify 120, 277 or 347V. Consult tech support for 208, 240 or 480V. 17 DMG not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, BL30, BL50, FAO and DS.18 DS not available with NLTAIR2 PIRHN, PIR, PER, PER5, PER7, BL30, BL50, FAO and DMG. 19 DS requires (2) separately switched circuits. DS provides 50/50 fixture operation via (2) different sets of leads using (2) drivers. DS only available with packages P8, P9, P10, P11, P12 and P13. 20 Reference Motion Sensor Default Settings table on page 4 to see functionality.21 Reference Controls Options table on page 4. 22 HS not available with T3LG, T4LG, BLC3, BLC4, LCCO and RCCO distribution. Also available as a separate accessory; see Accessories information.23 CCE option not available with option BS and EGSR. Contact Technical Support for availability. 24 Option HA not available with performance packages P4, P5, P7, P8, P9 and P13.25 Requires luminaire to be specified with PER, PER5 or PER7 option. See Controls Table on page 4. 26 Single fuse (SF) requires 120V, 277V, or 347V. Double fuse (DF) requires 208V, 240V or 480V. XVOLT not available with fusing (SF or DF). HANDHOLE ORIENTATION AHandhole B C D 1.75" for aluminum poles2.75" for other pole types Fixture Quantity & Mounting Configuration Single DM19 2 @ 180 DM28 2 @ 90 DM29 3 @ 90 DM39 3 @ 120 DM32 4 @ 90 DM49 Mounting Type DSX1 with SPA 0.69 1.38 1.23 1.54 ---1.58 DSX1 with SPA5, SPA8N 0.70 1.40 1.30 1.66 ---1.68 DSX1 with RPA, RPA5 0.70 1.40 1.30 1.66 1.60 1.68 DSX1 with MA 0.83 1.66 1.50 2.09 2.09 2.09 DSX1 Area Luminaire - EPA *Includes luminaire and integral mounting arm. Other tenons, arms, brackets or other accessories are not included in this EPA data. House Side Shield (HS) Minimum Acceptable Outside Pole Dimension SPA #8 3.5"3.5"3.5"3.5"3.5" RPA #8 3" 3" 3"3"3" 3" SPA5 #5 3" 3" 3"3"3" RPA5 #5 3" 3"3"3"3"3" SPA8N #8 3"3"3"3"3" Mounting Option Drilling Template Single 2 @ 180 2 @ 90 3 @ 90 3 @ 120 4 @ 90 Head Location Side B Side B & D Side B & C Side B, C & D Round Pole Only Side A, B, C & D Drill Nomenclature #8 DM19AS DM28AS DM29AS DM39AS DM32AS DM49AS One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 3 of 10 COMMERCIAL OUTDOOR To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s homepage. Photometric Diagrams Isofootcandle plots for the DSX1 LED P9 40K 70CRI. Distances are in units of mounting height (25’). LEGEND 0.1 fc 0.5 fc 1.0 fc T1S T2M T3M 4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T3LG T4M TFTM T4LG T5M T5W T5LG AFR BLC3 BLC4 LCCO RCCO 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 4 3 2 1 0 432165 65 4 3 2 1 0 -4 -3 -2 -1 5 6 -5 -6 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 4 of 10 COMMERCIAL OUTDOOR Performance Data Current (A) Performance Package LED Count Drive Current (mA)Wattage 120V 208V 240V 277V 347V 480V Forward Optics (Non-Rotated) P1 30 530 51 0.42 0.24 0.21 0.18 0.15 0.11 P2 30 700 68 0.56 0.33 0.28 0.24 0.20 0.14 P3 30 1050 104 0.85 0.49 0.43 0.37 0.29 0.21 P4 30 1250 125 1.03 0.60 0.52 0.45 0.36 0.26 P5 30 1400 142 1.15 0.66 0.58 0.50 0.40 0.29 P6 40 1250 167 1.38 0.79 0.69 0.60 0.48 0.34 P7 40 1400 188 1.54 0.89 0.77 0.67 0.53 0.38 P8 60 1100 216 1.80 1.04 0.90 0.78 0.62 0.45 P9 60 1400 279 2.31 1.33 1.15 1.00 0.80 0.58 Rotated Optics (Requires L90 or R90) P10 60 530 101 0.84 0.49 0.42 0.37 0.29 0.21 P11 60 700 135 1.12 0.65 0.56 0.49 0.39 0.28 P12 60 1050 206 1.72 0.99 0.86 0.74 0.59 0.43 P13 60 1400 279 2.30 1.33 1.15 1.00 0.79 0.57 Electrical Load Motion Sensor Default Settings Option Unoccupied Dimmed Level High Level (when occupied)Phototcell Operation Dwell Time Ramp-up Time Dimming Fade Rate PIR 30%100%Enabled @ 2FC 7.5 min 3 sec 5 min NLTAIR2 PIRHN 30%100%Enabled @ 2FC 7.5 min 3 sec 5 min Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Ambient Lumen Multiplier 0°C 32°F 1.04 5°C 41°F 1.04 10°C 50°F 1.03 15°C 50°F 1.02 20°C 68°F 1.01 25°C 77°C 1.00 30°C 86°F 0.99 35°C 95°F 0.98 40°C 104°F 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours Lumen Maintenance Factor 0 1.00 25,000 0.95 50,000 0.90 100,000 0.81 Controls Options Nomenclature Description Functionality Primary control device Notes FAO Field adjustable output device installed inside the luminaire; wired to the driver dimming leads.Allows the luminaire to be manually dimmed, effectively trimming the light output.FAO device Cannot be used with other controls options that need the 0-10V leads DS (not available on DSX0)Drivers wired independently for 50/50 luminaire operation The luminaire is wired to two separate circuits, allowing for 50/50 operation.Independently wired drivers Requires two separately switched circuits. Consider nLight AIR as a more cost effective alternative. PER5 or PER7 Twist-lock photocell receptacle Compatible with standard twist-lock photocells for dusk to dawn operation, or advanced control nodes that provide 0-10V dimming signals. Twist-lock photocells such as DLL Elite or advanced control nodes such as ROAM.Pins 4 & 5 to dimming leads on driver, Pins 6 & 7 are capped inside luminaire. Cannot be used with other controls options that need the 0-10V leads. PIR Motion sensor with integral photocell. Sensor suitable for 8' to 40' mounting height.Luminaires dim when no occupancy is detected.Acuity Controls rSBG Cannot be used with other controls options that need the 0-10V leads. NLTAIR2 PIRHN nLight AIR enabled luminaire for motion sensing, photocell and wireless communication.Motion and ambient light sensing with group response. Scheduled dimming with motion sensor over-ride when wirelessly connected to the nLight Eclypse. nLight Air rSBG nLight AIR sensors can be programmed and commissioned from the ground using the ClAIRity Pro app. Cannot be used with other controls options that need the 0-10V leads. BL30 or BL50 Integrated bi-level device that allows a second control circuit to switch all light engines to either 30% or 50% light output BLC device provides input to 0-10V dimming leads on all drivers providing either 100% or dimmed (30% or 50%) control by a secondary circuit BLC UVOLT1 BLC device is powered off the 0-10V dimming leads, thus can be used with any input voltage from 120 to 480V 70 CRI 80CRI 90CRI Lumen Multiplier Availability Lumen Multiplier Availability Lumen Multiplier Availability 5000K 102%Standard 92%Extended lead-time 71%(see note) 4000K 100%Standard 92%Extended lead-time 67%(see note) 3500K 100%(see note)90%Extended lead-time 63%(see note) 3000K 96%Standard 87%Extended lead-time 61%(see note) 2700K 94%(see note)85%Extended lead-time 57%(see note) LED Color Temperature / Color Rendering Multipliers Note: Some LED types are available as per special request. Contact Technical Support for more information.*Note: Calculated values are based on original performance package data. When calculating new values for given FAO position, use maximum published values by package listed on specification sheet (input watts and lumens by optic type). FAO Position % Wattage % Lumen Output 8 100%100% 7 93%95% 6 80%85% 5 66%73% 4 54%61% 3 41%49% 2 29%36% 1 15%20% FAO Dimming Settings One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 5 of 10 COMMERCIAL OUTDOOR Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79. Contact factory for performance data on any configurations not shown here. Forward Optics Performance Package System Watts LED Count Drive Current (mA)Distribution Type 30K 40K 50K (3000K, 70 CRI)(4000K, 70 CRI)(5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P1 51W 30 530 T1S 7,776 1 0 2 153 8,104 1 0 2 159 8,262 1 0 2 162 T2M 7,203 1 0 3 142 7,507 2 0 3 147 7,653 2 0 3 150 T3M 7,287 1 0 3 143 7,594 1 0 3 149 7,742 1 0 3 152 T3LG 6,509 1 0 1 128 6,783 1 0 1 133 6,916 1 0 1 136 T4M 7,395 1 0 3 145 7,707 1 0 3 151 7,857 1 0 3 154 T4LG 6,726 1 0 1 132 7,010 1 0 1 138 7,146 1 0 1 140 TFTM 7,446 1 0 3 146 7,760 1 0 3 152 7,912 1 0 3 155 T5M 7,609 3 0 2 149 7,930 3 0 2 156 8,084 3 0 2 159 T5W 7,732 3 0 2 152 8,058 4 0 2 158 8,215 4 0 2 161 T5LG 7,631 3 0 1 150 7,953 3 0 1 156 8,108 3 0 1 159 BLC3 5,300 0 0 2 104 5,524 0 0 2 109 5,631 0 0 2 111 BLC4 5,474 0 0 3 108 5,705 0 0 3 112 5,816 0 0 3 114 RCCO 5,348 0 0 2 105 5,573 0 0 2 109 5,682 0 0 2 112 LCCO 5,348 0 0 2 105 5,573 0 0 2 109 5,682 0 0 2 112 AFR 7,776 1 0 2 153 8,104 1 0 2 159 8,262 1 0 2 162 P2 68W 30 700 T1S 9,997 1 0 2 147 10,418 1 0 2 154 10,621 1 0 2 157 T2M 9,260 2 0 3 137 9,651 2 0 3 142 9,839 2 0 3 145 T3M 9,368 2 0 3 138 9,763 2 0 3 144 9,953 2 0 3 147 T3LG 8,368 1 0 2 123 8,721 1 0 2 129 8,891 1 0 2 131 T4M 9,507 2 0 3 140 9,909 2 0 3 146 10,102 2 0 3 149 T4LG 8,647 1 0 2 128 9,012 1 0 2 133 9,187 1 0 2 136 TFTM 9,573 2 0 3 141 9,977 2 0 3 147 10,172 2 0 3 150 T5M 9,782 4 0 2 144 10,195 4 0 2 150 10,393 4 0 2 153 T5W 9,940 4 0 2 147 10,360 4 0 2 153 10,562 4 0 2 156 T5LG 9,810 3 0 1 145 10,224 3 0 1 151 10,423 3 0 1 154 BLC3 6,814 0 0 2 101 7,101 0 0 2 105 7,240 0 0 2 107 BLC4 7,038 0 0 3 104 7,334 0 0 3 108 7,477 0 0 3 110 RCCO 6,875 1 0 2 101 7,165 1 0 2 106 7,305 1 0 2 108 LCCO 6,875 1 0 2 101 7,165 1 0 2 106 7,305 1 0 2 108 AFR 9,997 1 0 2 147 10,418 1 0 2 154 10,621 1 0 2 157 P3 102W 30 1050 T1S 14,093 2 0 2 138 14,687 2 0 2 144 14,973 2 0 2 147 T2M 13,055 2 0 3 128 13,605 2 0 3 133 13,871 2 0 3 136 T3M 13,206 2 0 4 129 13,763 2 0 4 135 14,031 2 0 4 137 T3LG 11,797 2 0 2 115 12,294 2 0 2 120 12,534 2 0 2 123 T4M 13,403 2 0 4 131 13,968 2 0 4 137 14,241 2 0 4 139 T4LG 12,190 2 0 2 119 12,704 2 0 2 124 12,952 2 0 2 127 TFTM 13,496 2 0 4 132 14,065 2 0 4 138 14,339 2 0 4 140 T5M 13,790 4 0 2 135 14,371 4 0 2 141 14,652 4 0 2 143 T5W 14,013 4 0 3 137 14,605 4 0 3 143 14,889 4 0 3 146 T5LG 13,830 3 0 2 135 14,413 3 0 2 141 14,694 3 0 2 144 BLC3 9,606 0 0 2 94 10,011 0 0 2 98 10,206 0 0 2 100 BLC4 9,921 0 0 3 97 10,340 0 0 3 101 10,541 0 0 3 103 RCCO 9,692 1 0 2 95 10,101 1 0 2 99 10,298 1 0 2 101 LCCO 9,692 1 0 2 95 10,101 1 0 2 99 10,298 1 0 2 101 AFR 14,093 2 0 2 138 14,687 2 0 2 144 14,973 2 0 2 147 Lumen Output One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 6 of 10 COMMERCIAL OUTDOOR Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79. Contact factory for performance data on any configurations not shown here. Forward Optics Performance Package System Watts LED Count Drive Current (mA)Distribution Type 30K 40K 50K (3000K, 70 CRI)(4000K, 70 CRI)(5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P4 124W 30 1250 T1S 16,416 2 0 3 132 17,109 2 0 3 138 17,442 2 0 3 141 T2M 15,207 3 0 4 123 15,849 3 0 4 128 16,158 3 0 4 130 T3M 15,383 2 0 4 124 16,032 2 0 4 129 16,345 2 0 4 132 T3LG 13,742 2 0 2 111 14,321 2 0 2 116 14,600 2 0 2 118 T4M 15,613 2 0 4 126 16,272 2 0 4 131 16,589 2 0 4 134 T4LG 14,200 2 0 2 115 14,799 2 0 2 119 15,087 2 0 2 122 TFTM 15,721 2 0 4 127 16,384 2 0 4 132 16,703 2 0 4 135 T5M 16,063 4 0 2 130 16,741 4 0 2 135 17,067 4 0 2 138 T5W 16,324 5 0 3 132 17,013 5 0 3 137 17,344 5 0 3 140 T5LG 16,110 3 0 2 130 16,790 4 0 2 135 17,117 4 0 2 138 BLC3 11,190 0 0 3 90 11,662 0 0 3 94 11,889 0 0 3 96 BLC4 11,557 0 0 3 93 12,044 0 0 3 97 12,279 0 0 4 99 RCCO 11,291 1 0 3 91 11,767 1 0 3 95 11,996 1 0 3 97 LCCO 11,291 1 0 3 91 11,767 1 0 3 95 11,996 1 0 3 97 AFR 16,416 2 0 3 132 17,109 2 0 3 138 17,442 2 0 3 141 P5 138W 30 1400 T1S 18,052 2 0 3 131 18,814 2 0 3 136 19,180 2 0 3 139 T2M 16,723 3 0 4 121 17,428 3 0 4 126 17,768 3 0 4 129 T3M 16,917 3 0 4 122 17,630 3 0 4 128 17,974 3 0 4 130 T3LG 15,111 2 0 2 109 15,749 2 0 2 114 16,055 2 0 2 116 T4M 17,169 3 0 5 124 17,893 3 0 5 130 18,242 3 0 5 132 T4LG 15,615 2 0 2 113 16,274 2 0 2 118 16,591 2 0 2 120 TFTM 17,288 2 0 4 125 18,017 2 0 5 130 18,368 3 0 5 133 T5M 17,664 5 0 3 128 18,410 5 0 3 133 18,768 5 0 3 136 T5W 17,951 5 0 3 130 18,708 5 0 3 135 19,073 5 0 3 138 T5LG 17,716 4 0 2 128 18,463 4 0 2 134 18,823 4 0 2 136 BLC3 12,305 0 0 3 89 12,824 0 0 3 93 13,074 0 0 3 95 BLC4 12,709 0 0 4 92 13,245 0 0 4 96 13,503 0 0 4 98 RCCO 12,416 1 0 3 90 12,940 1 0 3 94 13,192 1 0 3 95 LCCO 12,416 1 0 3 90 12,940 1 0 3 94 13,192 1 0 3 95 AFR 18,052 2 0 3 131 18,814 2 0 3 136 19,180 2 0 3 139 P6 165W 40 1250 T1S 21,031 2 0 3 127 21,918 2 0 3 133 22,345 2 0 3 135 T2M 19,482 3 0 4 118 20,303 3 0 4 123 20,699 3 0 4 125 T3M 19,708 3 0 5 119 20,539 3 0 5 124 20,939 3 0 5 127 T3LG 17,604 2 0 2 107 18,347 2 0 2 111 18,704 2 0 2 113 T4M 20,001 3 0 5 121 20,845 3 0 5 126 21,251 3 0 5 129 T4LG 18,191 2 0 2 110 18,959 2 0 2 115 19,328 2 0 2 117 TFTM 20,140 3 0 5 122 20,989 3 0 5 127 21,398 3 0 5 129 T5M 20,579 5 0 3 125 21,447 5 0 3 130 21,865 5 0 3 132 T5W 20,912 5 0 3 127 21,795 5 0 3 132 22,219 5 0 3 134 T5LG 20,638 4 0 2 125 21,509 4 0 2 130 21,928 4 0 2 133 BLC3 14,335 0 0 3 87 14,940 0 0 3 90 15,231 0 0 3 92 BLC4 14,805 0 0 4 90 15,430 0 0 4 93 15,731 0 0 4 95 RCCO 14,464 1 0 3 88 15,074 1 0 3 91 15,368 1 0 3 93 LCCO 14,464 1 0 3 88 15,074 1 0 3 91 15,368 1 0 3 93 AFR 21,031 2 0 3 127 21,918 2 0 3 133 22,345 2 0 3 135 Lumen Output One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 7 of 10 COMMERCIAL OUTDOOR Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79. Contact factory for performance data on any configurations not shown here. Forward Optics Performance Package System Watts LED Count Drive Current (mA)Distribution Type 30K 40K 50K (3000K, 70 CRI)(4000K, 70 CRI)(5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P7 184W 40 1400 T1S 22,741 2 0 3 123 23,700 2 0 3 129 24,162 3 0 3 131 T2M 21,066 3 0 4 114 21,955 3 0 4 119 22,383 3 0 4 121 T3M 21,311 3 0 5 116 22,210 3 0 5 120 22,642 3 0 5 123 T3LG 19,036 2 0 2 103 19,839 2 0 3 108 20,226 2 0 3 110 T4M 21,628 3 0 5 117 22,541 3 0 5 122 22,980 3 0 5 125 T4LG 19,671 2 0 2 107 20,501 2 0 3 111 20,900 2 0 3 113 TFTM 21,778 3 0 5 118 22,697 3 0 5 123 23,139 3 0 5 125 T5M 22,252 5 0 3 121 23,191 5 0 3 126 23,643 5 0 3 128 T5W 22,613 5 0 3 123 23,567 5 0 4 128 24,027 5 0 4 130 T5LG 22,317 4 0 2 121 23,258 4 0 2 126 23,712 4 0 2 129 BLC3 15,501 0 0 3 84 16,155 0 0 4 88 16,470 0 0 4 89 BLC4 16,010 0 0 4 87 16,685 0 0 4 90 17,010 0 0 4 92 RCCO 15,641 1 0 3 85 16,301 1 0 3 89 16,619 1 0 3 90 LCCO 15,641 1 0 3 85 16,301 1 0 3 89 16,619 1 0 3 90 AFR 22,741 2 0 3 123 23,700 2 0 3 129 24,162 3 0 3 131 P8 216W 60 1100 T1S 28,701 3 0 3 133 29,912 3 0 4 139 30,495 3 0 4 141 T2M 26,587 3 0 5 123 27,709 3 0 5 128 28,249 3 0 5 131 T3M 26,895 3 0 5 125 28,030 3 0 5 130 28,576 3 0 5 132 T3LG 24,025 3 0 3 111 25,038 3 0 3 116 25,526 3 0 3 118 T4M 27,296 3 0 5 127 28,448 3 0 5 132 29,002 3 0 5 134 T4LG 24,826 3 0 3 115 25,873 3 0 3 120 26,378 3 0 3 122 TFTM 27,485 3 0 5 127 28,645 3 0 5 133 29,203 3 0 5 135 T5M 28,084 5 0 4 130 29,269 5 0 4 136 29,839 5 0 4 138 T5W 28,539 5 0 4 132 29,743 5 0 4 138 30,323 5 0 4 141 T5LG 28,165 4 0 2 131 29,354 4 0 2 136 29,926 4 0 2 139 BLC3 19,563 0 0 4 91 20,388 0 0 4 94 20,786 0 0 4 96 BLC4 20,205 0 0 5 94 21,057 0 0 5 98 21,468 0 0 5 99 RCCO 19,740 1 0 4 91 20,572 1 0 4 95 20,973 1 0 4 97 LCCO 19,740 1 0 4 91 20,572 1 0 4 95 20,973 1 0 4 97 AFR 28,701 3 0 3 133 29,912 3 0 4 139 30,495 3 0 4 141 P9 277W 60 1400 T1S 34,819 3 0 4 126 36,288 3 0 4 131 36,996 3 0 4 134 T2M 32,255 3 0 5 116 33,616 3 0 5 121 34,271 3 0 5 124 T3M 32,629 3 0 5 118 34,006 3 0 5 123 34,668 3 0 5 125 T3LG 29,146 3 0 3 105 30,376 3 0 4 110 30,968 3 0 4 112 T4M 33,116 3 0 5 120 34,513 3 0 5 125 35,185 3 0 5 127 T4LG 30,119 3 0 3 109 31,389 3 0 4 113 32,001 3 0 4 116 TFTM 33,345 3 0 5 120 34,751 3 0 5 125 35,429 3 0 5 128 T5M 34,071 5 0 4 123 35,509 5 0 4 128 36,201 5 0 4 131 T5W 34,624 5 0 4 125 36,084 5 0 4 130 36,788 5 0 4 133 T5LG 34,170 5 0 3 123 35,612 5 0 3 129 36,306 5 0 3 131 BLC3 23,734 0 0 4 86 24,735 0 0 4 89 25,217 0 0 4 91 BLC4 24,513 0 0 5 88 25,547 0 0 5 92 26,045 0 0 5 94 RCCO 23,948 1 0 4 86 24,958 1 0 4 90 25,445 1 0 4 92 LCCO 23,948 1 0 4 86 24,958 1 0 4 90 25,445 1 0 4 92 AFR 34,819 3 0 4 126 36,288 3 0 4 131 36,996 3 0 4 134 Lumen Output One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 8 of 10 COMMERCIAL OUTDOOR Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of configurations shown within the tolerances described within LM-79. Contact factory for performance data on any configurations not shown here. Rotated Optics Performance Package System Watts LED Count Drive Current (mA)Distribution Type 30K 40K 50K (3000K, 70 CRI)(4000K, 70 CRI)(5000K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW P10 101W 60 530 T1S 15,164 3 0 3 150 15,803 3 0 3 156 16,112 3 0 3 159 T2M 14,047 4 0 4 139 14,640 4 0 4 145 14,925 4 0 4 147 T3M 14,208 4 0 4 140 14,807 4 0 4 146 15,096 4 0 4 149 T3LG 12,693 3 0 3 125 13,229 3 0 3 131 13,487 3 0 3 133 T4M 14,420 4 0 4 142 15,028 4 0 4 148 15,321 4 0 4 151 T4LG 13,115 3 0 3 129 13,668 3 0 3 135 13,934 3 0 3 138 TFTM 14,522 4 0 4 143 15,134 4 0 4 149 15,429 4 0 4 152 T5M 14,836 4 0 2 146 15,462 4 0 2 153 15,763 4 0 2 156 T5W 15,076 4 0 3 149 15,712 5 0 3 155 16,019 5 0 3 158 T5LG 14,879 3 0 2 147 15,507 3 0 2 153 15,809 3 0 2 156 BLC3 10,335 3 0 3 102 10,771 4 0 4 106 10,981 4 0 4 108 BLC4 10,674 4 0 4 105 11,124 4 0 4 110 11,341 4 0 4 112 RCCO 10,429 1 0 2 103 10,869 1 0 2 107 11,080 1 0 2 109 LCCO 10,429 1 0 2 103 10,869 1 0 2 107 11,080 1 0 2 109 AFR 15,164 3 0 3 150 15,803 3 0 3 156 16,112 3 0 3 159 P11 135W 60 700 T1S 19,437 4 0 4 144 20,257 4 0 4 150 20,651 4 0 4 153 T2M 18,005 4 0 4 133 18,765 4 0 4 139 19,131 4 0 4 142 T3M 18,211 4 0 4 135 18,980 4 0 4 141 19,350 4 0 4 143 T3LG 16,270 3 0 3 121 16,957 3 0 3 126 17,287 4 0 4 128 T4M 18,483 4 0 4 137 19,263 5 0 5 143 19,638 5 0 5 146 T4LG 16,810 3 0 3 125 17,519 3 0 3 130 17,861 3 0 3 132 TFTM 18,614 4 0 4 138 19,399 4 0 4 144 19,777 5 0 5 147 T5M 19,017 5 0 3 141 19,819 5 0 3 147 20,205 5 0 3 150 T5W 19,325 5 0 3 143 20,140 5 0 3 149 20,533 5 0 3 152 T5LG 19,072 4 0 2 141 19,876 4 0 2 147 20,264 4 0 2 150 BLC3 13,247 4 0 4 98 13,806 4 0 4 102 14,075 4 0 4 104 BLC4 13,682 4 0 4 101 14,259 4 0 4 106 14,537 4 0 4 108 RCCO 13,367 1 0 3 99 13,931 1 0 3 103 14,203 1 0 3 105 LCCO 13,367 1 0 3 99 13,931 1 0 3 103 14,203 1 0 3 105 AFR 19,437 4 0 4 144 20,257 4 0 4 150 20,651 4 0 4 153 P12 206W 60 1050 T1S 27,457 4 0 4 133 28,616 4 0 4 139 29,174 4 0 4 142 T2M 25,436 5 0 5 124 26,509 5 0 5 129 27,025 5 0 5 131 T3M 25,727 5 0 5 125 26,812 5 0 5 130 27,335 5 0 5 133 T3LG 22,984 4 0 4 112 23,954 4 0 4 116 24,421 4 0 4 119 T4M 26,110 5 0 5 127 27,212 5 0 5 132 27,742 5 0 5 135 T4LG 23,747 4 0 4 115 24,749 4 0 4 120 25,231 4 0 4 123 TFTM 26,295 5 0 5 128 27,404 5 0 5 133 27,938 5 0 5 136 T5M 26,864 5 0 4 130 27,997 5 0 4 136 28,543 5 0 4 139 T5W 27,299 5 0 4 133 28,451 5 0 4 138 29,006 5 0 4 141 T5LG 26,942 4 0 2 131 28,078 4 0 2 136 28,626 4 0 2 139 BLC3 18,714 4 0 4 91 19,504 4 0 4 95 19,884 4 0 4 97 BLC4 19,327 5 0 5 94 20,143 5 0 5 98 20,535 5 0 5 100 RCCO 18,883 1 0 4 92 19,680 1 0 4 96 20,064 1 0 4 97 LCCO 18,883 1 0 4 92 19,680 1 0 4 96 20,064 1 0 4 97 AFR 27,457 4 0 4 133 28,616 4 0 4 139 29,174 4 0 4 142 P13 276W 60 1400 T1S 34,436 5 0 5 125 35,889 5 0 5 130 36,588 5 0 5 133 T2M 31,900 5 0 5 116 33,246 5 0 5 121 33,894 5 0 5 123 T3M 32,265 5 0 5 117 33,626 5 0 5 122 34,282 5 0 5 124 T3LG 28,826 4 0 4 105 30,042 4 0 4 109 30,628 4 0 4 111 T4M 32,746 5 0 5 119 34,128 5 0 5 124 34,793 5 0 5 126 T4LG 29,782 4 0 4 108 31,039 4 0 4 113 31,644 5 0 4 115 TFTM 32,978 5 0 5 120 34,369 5 0 5 125 35,039 5 0 5 127 T5M 33,692 5 0 4 122 35,113 5 0 4 127 35,797 5 0 4 130 T5W 34,238 5 0 4 124 35,682 5 0 4 129 36,378 5 0 4 132 T5LG 33,789 5 0 3 122 35,215 5 0 3 128 35,901 5 0 3 130 BLC3 23,471 5 0 5 85 24,461 5 0 5 89 24,937 5 0 5 90 BLC4 24,240 5 0 5 88 25,262 5 0 5 92 25,755 5 0 5 93 RCCO 23,683 1 0 4 86 24,682 1 0 4 89 25,163 1 0 4 91 LCCO 23,683 1 0 4 86 24,682 1 0 4 89 25,163 1 0 4 91 AFR 34,436 5 0 5 125 35,889 5 0 5 130 36,588 5 0 5 133 Lumen Output One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 9 of 10 COMMERCIAL OUTDOOR 2.73" 34.23" 14.26" 8.21" 2.73" 34.53" 14.26" 8.90" 2.73" 38.71" 14.26" 7.88" Dimensions DSX1 with RPA, RPA5, SPA5, SPA8N mount Weight: 36 lbs DSX1 with WBA mount Weight: 38 lbs DSX1 with MA mount Weight: 39 lbs 2.41" 3.16" SPA (STANDARD ARM) 2.41"3.16" RPA 2.41" 3.16" SPA8N 4.25" RPA5 4.25" SPA5 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2023 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 09/05/23 Page 10 of 10 COMMERCIAL OUTDOOR nLight Control - Sensor Coverage and Settings nLight Sensor Coverage Pattern NLTAIR2 PIRHN Top Side FEATURES & SPECIFICATIONS INTENDED USE The sleek design of the D-Series Size 1 reflects the embedded high performance LED technology. It is ideal for many commercial and municipal applications, such as parking lots, plazas, campuses, and streetscapes. CONSTRUCTION Single-piece die-cast aluminum housing has integral heat sink fins to optimize thermal management through conductive and convective cooling. Modular design allows for ease of maintenance and future light engine upgrades. The LED drivers are mounted in direct contact with the casting to promote low operating temperature and long life. Housing driver compartment is completely sealed against moisture and environmental contaminants (IP66). Vibration rated per ANSI C136.31 for 3G for SPA and MA. 1.5G for mountings RPA, RPA5, SPA5 and SPA8N. Low EPA (0.69 ft2) for optimized pole wind loading. FINISH Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weather- ing. A tightly controlled multi-stage process ensures a minimum 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peel- ing. Available in both textured and non-textured finishes. Coastal Construction (CCE) Optional corrosion resistant construction is engineered with added corrosion protection in materials and/or pre-treatment of base material under super durable paint. Provides additional corrosion protection for applications near coastal areas. Finish is salt spray tested to over 5,000 hours per ASTM B117 with scribe rating of 10. Additional lead-times may apply. OPTICS Precision-molded proprietary silicone lenses are engineered for superior area lighting distribution, uniformity, and pole spacing. Light engines are available in standard 3000 K, 4000 K and 5000 K (70 CRI) configurations. 80CRI configura- tions are also available. The D-Series Size 1 has zero uplight and qualifies as a Nighttime Friendly™ product, meaning it is consistent with the LEED® and Green Globes™ criteria for eliminating wasteful uplight. ELECTRICAL Light engine configurations consist of high-efficacy LEDs mounted to metal- core circuit boards to maximize heat dissipation and promote long life (up to L81/100,000 hours at 25°C). Class 1 electronic drivers are designed to have a power factor >90%, THD <20%, and an expected life of 100,000 hours with <1% failure rate. Easily serviceable 10kV surge protection device meets a minimum Category C Low operation (per ANSI/IEEE C62.41.2). STANDARD CONTROLS The DSX1 LED area luminaire has a number of control options. DSX Size 1, comes standard with 0-10V dimming drivers. Dusk to dawn controls can be utilized via optional NEMA twist-lock photocell receptacles. Integrated motion sensor with on-board photocells feature field-adjustable programing and are suitable for mounting heights up to 40 feet. Control option BL features a bi-level device that allows a second control circuit to switch all light engines to either 30% or 50% light output. nLIGHT AIR CONTROLS The DSX1 LED area luminaire is also available with nLight® AIR for the ultimate in wireless control. This powerful controls platform provides out-of-the-box basic motion sensing and photocontrol functionality and is suitable for mounting heights up to 40 feet. Once commissioned using a smartphone and the easy-to- use CLAIRITY app, nLight AIR equipped luminaries can be grouped, resulting in motion sensor and photocell group response without the need for additional equipment. Scheduled dimming with motion sensor over-ride can be achieved when used with the nLight Eclypse. Additional information about nLight Air can be found here. INSTALLATION Integral mounting arm allows for fast mounting using Lithonia standard #8 drill- ing and accommodates pole drilling's from 2.41 to 3.12" on center. The standard “SPA” option for square poles and the “RPA” option for round poles use the #8 drilling. For #5 pole drillings, use SPA5 or RPA5. Additional mountings are available including a wall bracket (WBA) and mast arm (MA) option that allows luminaire attachment to a 2 3/8” horizontal mast arm. LISTINGS UL listed to meet U.S. and Canadian standards. UL Listed for wet locations. Light engines are IP66 rated; luminaire is IP66 rated. Rated for -40°C minimum ambient. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/ QPL to confirm which versions are qualified. International Dark-Sky Association (IDA) Fixture Seal of Approval (FSA) is available for all products on this page utilizing 3000K color temperature only. BUY AMERICAN ACT Product with the BAA option is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT regulations. Please refer to www.acuitybrands.com/buy-american for additional information. WARRANTY 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice.