Loading...
HomeMy WebLinkAbout047 Towneplace Suites - Landscape Irrigation DetailsFINISH GRADE ROTOR - SIZE PER PLAN PVC LATERAL PIPE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL (S x T) WALLS, WALKS, COURTS, CURB, ETC. 1 2 3 4 5 6 5 4 3 2 1 NOTE: 1.SET TOP OF HEAD FLUSH WITH FINISH GRADE. 2.ADJUSTABLE ARC NOZZLES SHALL BE USED ON CURVED OR NON-STANDARD ANGLED EDGES. 3.ROTORS SHALL BE INSTALLED 6" MININUM FROM ANY WALLS, WALKS, COURTS, ETC. PER LOCAL CODES 4.ADJUST ALL ROTOR HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 5.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 6" MIN. OR PER LOCAL CODE 6 ROTOR POP-UP SCALE: NTS FINISH GRADE POP-UP SPRAY HEAD PER SCHEDULE PVC LATERAL PIPE SWING JOINT ASSEMBLY PVC SCH. 40 TEE OR ELL (S x T) WALLS, WALKS, COURTS, CURB, ETC. 1 2 3 4 5 6 NOTE: 1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE. 2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 12" FROM TURF EDGE. 3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS, COURTS, ETC. 4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 6 SPRAY POP-UP SCALE: NTS 6" MIN. OR PER LOCAL CODE 5 1 2 3 4 PAVING WRAP 12 GAUGE GALVANIZED WIRE AROUND EACH END OF SLEEVE (10 WRAPS MIN.) AND EXTEND TO SURFACE AS A LOCATING DEVICE FINISH GRADE / TOP OF DG COMPACT SOIL AROUND SLEEVE TO SAME DENSITY AS ADJACENT UNDISTURBED SOIL WASHED AND GRADED MORTAR SAND BACKFILL IN ROCKY SOIL CONDITIONS PVC SLEEVE PER SCHEDULE, TWICE DIAMETER OF THE SUM OF THE PIPES/ WIRES EXTEND SLEEVES 6" BEYOND EDGES OF PAVING 1 2 3 4 5 6 7 NOTE: 1.ALL SLEEVES SHALL BE INSPECTED PRIOR TO BACKFILLING. 2.CAP SLEEVES UNTIL USE. 3.MULTIPLE SLEEVES REQUIRE 4" HORIZONTAL SEPARATION WITHIN SAME SLEEVE TRENCH. 4.IRRIGATION PIPE AND WIRE SHALL NOT SHARE THE SAME SLEEVE. 5.MARK / STAMP - 'X' AND/OR INSTALL PLACARD AT BACK OF CURB. 6" MIN. 18" MIN. DEPTH 24" MIN. DEPTH FOR MAINLINE 1 2 3 4 5 6 7 PIPE SLEEVE SCALE: NTS SNAKE PVC OR POLYETHYLENE PIPE IN TRENCH EXCAVATED COVER MATERIAL (SEE NOTES) FINISH GRADE MAINLINE MARKING TAPE (PURPLE MARKING TAPE IF RECLAIMED) POLYETHYLENE DRIP LATERAL/ DRIP PVC LATERAL PIPE (6" MIN. COVERAGE, 18" MIN. COVERAGE BELOW PEDESTRIAN WALKS.) IRRIGATION LATERAL PIPE IRRIGATION MAINLINE PIPE VALVE WIRING BEDDING MATERIAL (SEE NOTES) 1 2 3 4 5 6 7 8 9 NOTE: 1.ALL MAINLINES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER' SPECIFICATIONS. 2.ALL PVC PIPING TO BE SNAKED IN TRENCHES AS SHOWN IN PLAN VIEW ABOVE. 3.ALL 120 VOLT WIRING IN CONDUIT TO BE INSTALLED AS PER LOCAL CODES. 4.ALL ELECTRICAL WIRE CONNECTIONS TO VALVES AND SPLICES TO BE INSTALLED WITHIN A VALVE BOX AND MADE WITH DBY WATERPROOF CONNECTORS, OR APPROVED EQUAL. 5.BUNDLE AND TAPE WIRING AT 10' INTERVALS 6.VALVE WIRES TO BE INSTALLED WITHIN MAINLINE TRENCH WHEREVER POSSIBLE. 7.BEDDING MATERIAL SHALL BE 1/4” MINUS SAND, AND SHALL BE 3” BELOW LOWEST PIPE OR WIRE AND 3” ABOVE HIGHEST PIPE OR WEIR WITHIN TRENCH. 8.BEDDING MATERIAL SHALL BE IN MAINLINE TRENCH ONLY. 9.BEDDING IS NOT REQUIRED IN POLYETHYLENE TUBING TRENCHES. 10.EXCAVATED COVER MATERIAL SHALL BE FREE FROM DEBRIS AND ROCKS 1/2” OR GREATER. 11.PIPE BEDDING MATERIAL TO BE ROCK AND DEBRIS FREE, BACKFILL IN 6” LIFTS, PUDDLE WITH WATER, BETWEEN LIFTS. SECTION PIPE TRENCH SCALE: NTS 1 9 3 8 7 6 4 2 5 24"18" 6" PLAN 10' 1/4" DISTRIBUTION TUBING. RUN TUBING UNDER WEED BARRIER FABRIC TO PLANT. LENGTH NOT TO EXCEED 8' UNIVERSAL 1/4" STAKE DIFFUSER CAP TOP OF MULCH PRESSURE COMPENSATING EMITTER PER EMITTER SCHEDULE. INSTALL EMITTER AT 45° TO 60° ANGLE 3/4" POLYETHYLENE TUBING SET WITH TOP OF TUBING FLUSH WITH FINISH GRADE OF SOIL FINISH GRADE OF SOIL WEED BARRIER FABRIC 1 2 3 4 5 6 7 8 SINGLE OUTLET EMITTER SCALE: NTS 1 2 3 4 7 5 6 8 SINGLE OUTLET EMITTER PLACEMENT SCALE: NTS DIFFUSER CAP W/ DRIP STAKE PLANT CENTER PLANT ROOTBALL SINGLE OUTLET EMITTER 3/4" POLYETHYLENE DRIP TUBING 1/4" DISTRIBUTION TUBING (LENGTH NOT TO EXCEED 8') 1 2 3 4 5 6 NOTE: 1.EMITTERS SHALL BE EQUALLY SPACED AROUND ROOTBALL. 2.FLUSH ALL LINES THOROUGHLY PRIOR TO EMITTER INSTALLATION. 2.IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL EMITTERS ON THE UPHILL SIDE OF PLANT. 3.EMITTERS SHALL BE SELF-FLUSHING PRESSURE COMPENSATING-TYPE UNLESS NOTED OTHERWISE. 4.DRIP VALVE ZONES (HYDROZONES) ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT REQUIREMENTS AND SUN EXPOSURE. 5.CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN. 1 2 3 4 5 6 1 3 6 56 EMISSION POINT. DIFFUSER CAP W/ DRIP STAKE (TYP.) PLANT ROOT BALL (TYP.) PLANT CENTER (TYP.) SECOND EMISSION POINTS SEE NOTE 3 BELOW TREE TRUNK MULCH LAYER 1/4" DISTRIBUTION TUBING (LENGTH NOT TO EXCEED 8') 3/4" POLYETHYLENE DRIP TUBING SINGLE OUTLET EMITTER ROOTBALL 1 2 3 4 5 6 7 8 9 10 TREE EMITTER PLACEMENT SCALE: NTS 60°60° 60° 6 0 °60°NOTE: 1.MAXIMUM LENGTH OF ONE DISTRIBUTION TUBE SHALL BE 8'. 2.ALL EMISSION POINTS SHALL BE LOCATED ON UPHILL SIDE OF PLANT MATERIAL. ONE EMISSION POINT SHALL BE DIRECTLY TO PLANT BALL AS INDICATED. ADDITIONAL EMISSION POINTS SHALL BE WITHIN PLANT PIT PERIMETER AS DIRECTED IN THE EMITTER SCHEDULE. 3.SECOND EMISSION POINTS (IF NEEDED) AS PER THE EMITTER SCHEDULE FOR TREES WITH 3" CALIPER OR GREATER OR CONIFEROUS TREES 10' OR GREATER IN HEIGHT. 4.THIS IS A WATERING GUIDE ONLY. SITE, SOIL AND PLANT CONDITIONS VARY GREATLY. CONTRACTOR MUST OBSERVE THE PLANT MATERIAL AND MAKE ADJUSTMENTS AS NECESSARY FOR PROPER PLANT WATER REQUIREMENT. 1 2 3 4 5 1 6 7 8 9 10 6" MIN. 12" MAX. 8 7 10 NOTE: 1.COMPACT SOIL AROUND VALVE BOX TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE. 2.SECURE STAKE TO FLUSH END CAP OR PVC NIPPLE WITH A MIN. OF 2 HOSE CLAMPS. 3.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE. 1 7 2 8 3 9 4 5 6 4" POP-UP HEAD WITH ENCLOSED NOZZLE AND SWING PIPE. (ZONE OPERATIONAL INDICATOR) LOCKING ROUND BOX & COVER PER SCHEDULE. TOP OF BOX TO BE FLUSH WITH FINISH GRADE HOSE END SELF FLUSH CAP FINISH GRADE 24" #4 REBAR TO HOLD END CAP IN PLACE W/ (2) STAINLESS STEEL HOSE CLAMPS 3/4" POLYETHYLENE DRIP TUBING ELBOW COMPRESSION FITTING 3/4" GRAVEL SUMP, 4" DEPTH BRICK (2 REQUIRED MIN.) RISER (LENGTH AS NEEDED) COMPRESSION TEE W/ POLY TO PVC ADAPTER PVC LATERAL 1 2 3 4 5 6 7 8 9 10 11 12 DRIP FLUSH END CAP WITH INDICATOR SCALE: NTS2"MIN.10 11 12 1 4 7 2 5 8 3 6 IRRIGATION DETAILS LI501 OWNER: DATE: SHEET TITLE:CHECKED BY:DRAWN BY:TOWNEPLACE SUITES HOTEL - BOZEMAN WESTSITE PLAN DESIGNNORTHEAST CORNER OF N27TH AVE AND HONOR LANE | BOZEMAN, MT.BRAXTON DEVELOPMENT 1735 S. 19TH AVE. SUITE B BOZEMAN, MT 59718 406.582.8100 JB, REJS01/25/23: SITE PLAN 06/09/23: SITE PLAN R 1101 Bannock Street Denver, CO 80204 P 303.892.1166 www.norris-design.com