HomeMy WebLinkAbout047 Towneplace Suites - Landscape Irrigation DetailsFINISH GRADE
ROTOR - SIZE PER PLAN
PVC LATERAL PIPE
SWING JOINT ASSEMBLY
PVC SCH. 40 TEE OR ELL (S x T)
WALLS, WALKS, COURTS, CURB,
ETC.
1
2
3
4
5
6
5
4
3
2
1
NOTE:
1.SET TOP OF HEAD FLUSH WITH FINISH GRADE.
2.ADJUSTABLE ARC NOZZLES SHALL BE USED ON CURVED OR NON-STANDARD ANGLED EDGES.
3.ROTORS SHALL BE INSTALLED 6" MININUM FROM ANY WALLS, WALKS, COURTS, ETC. PER LOCAL
CODES
4.ADJUST ALL ROTOR HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS,
COURTS, ETC.
5.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
6" MIN. OR PER
LOCAL CODE
6
ROTOR POP-UP
SCALE: NTS
FINISH GRADE
POP-UP SPRAY HEAD PER
SCHEDULE
PVC LATERAL PIPE
SWING JOINT ASSEMBLY
PVC SCH. 40 TEE OR ELL (S x T)
WALLS, WALKS, COURTS, CURB,
ETC.
1
2
3
4
5
6
NOTE:
1.AFTER FLUSHING HEADS, REGRADE AND COMPACT AS NEEDED TO RETURN TO FINISH GRADE.
2.SPRINKLERS SHALL BE MIN. 6" FROM ANY WALLS, WALKS, COURTS, AND 12" FROM TURF EDGE.
3.ADJUST ALL SPRINKLERS HEADS SO THAT NO OVERSPRAY OCCURS ON ANY WALLS, WALKS,
COURTS, ETC.
4.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
5.COMPACT SOIL AROUND HEAD TO THE SAME DENSITY AS ADJACENT UNDISTURBED SUBGRADE.
6
SPRAY POP-UP
SCALE: NTS
6" MIN. OR PER
LOCAL CODE
5
1
2
3
4
PAVING
WRAP 12 GAUGE GALVANIZED
WIRE AROUND EACH END OF
SLEEVE (10 WRAPS MIN.) AND
EXTEND TO SURFACE AS A
LOCATING DEVICE
FINISH GRADE / TOP OF DG
COMPACT SOIL AROUND
SLEEVE TO SAME DENSITY AS
ADJACENT UNDISTURBED SOIL
WASHED AND GRADED
MORTAR SAND BACKFILL IN
ROCKY SOIL CONDITIONS
PVC SLEEVE PER SCHEDULE,
TWICE DIAMETER OF THE SUM
OF THE PIPES/ WIRES
EXTEND SLEEVES 6" BEYOND
EDGES OF PAVING
1
2
3
4
5
6
7
NOTE:
1.ALL SLEEVES SHALL BE INSPECTED PRIOR TO BACKFILLING.
2.CAP SLEEVES UNTIL USE.
3.MULTIPLE SLEEVES REQUIRE 4" HORIZONTAL SEPARATION WITHIN SAME SLEEVE TRENCH.
4.IRRIGATION PIPE AND WIRE SHALL NOT SHARE THE SAME SLEEVE.
5.MARK / STAMP - 'X' AND/OR INSTALL PLACARD AT BACK OF CURB.
6" MIN.
18" MIN. DEPTH
24" MIN. DEPTH
FOR MAINLINE
1
2
3
4
5
6
7
PIPE SLEEVE
SCALE: NTS
SNAKE PVC OR POLYETHYLENE
PIPE IN TRENCH
EXCAVATED COVER MATERIAL
(SEE NOTES)
FINISH GRADE
MAINLINE MARKING TAPE
(PURPLE MARKING TAPE IF
RECLAIMED)
POLYETHYLENE DRIP LATERAL/
DRIP PVC LATERAL PIPE (6"
MIN. COVERAGE, 18" MIN.
COVERAGE BELOW
PEDESTRIAN WALKS.)
IRRIGATION LATERAL PIPE
IRRIGATION MAINLINE PIPE
VALVE WIRING
BEDDING MATERIAL (SEE
NOTES)
1
2
3
4
5
6
7
8
9
NOTE:
1.ALL MAINLINES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER' SPECIFICATIONS.
2.ALL PVC PIPING TO BE SNAKED IN TRENCHES AS SHOWN IN PLAN VIEW ABOVE.
3.ALL 120 VOLT WIRING IN CONDUIT TO BE INSTALLED AS PER LOCAL CODES.
4.ALL ELECTRICAL WIRE CONNECTIONS TO VALVES AND SPLICES TO BE INSTALLED WITHIN A
VALVE BOX AND MADE WITH DBY WATERPROOF CONNECTORS, OR APPROVED EQUAL.
5.BUNDLE AND TAPE WIRING AT 10' INTERVALS
6.VALVE WIRES TO BE INSTALLED WITHIN MAINLINE TRENCH WHEREVER POSSIBLE.
7.BEDDING MATERIAL SHALL BE 1/4” MINUS SAND, AND SHALL BE 3” BELOW LOWEST PIPE OR
WIRE AND 3” ABOVE HIGHEST PIPE OR WEIR WITHIN TRENCH.
8.BEDDING MATERIAL SHALL BE IN MAINLINE TRENCH ONLY.
9.BEDDING IS NOT REQUIRED IN POLYETHYLENE TUBING TRENCHES.
10.EXCAVATED COVER MATERIAL SHALL BE FREE FROM DEBRIS AND ROCKS 1/2” OR GREATER.
11.PIPE BEDDING MATERIAL TO BE ROCK AND DEBRIS FREE, BACKFILL IN 6” LIFTS, PUDDLE WITH
WATER, BETWEEN LIFTS.
SECTION
PIPE TRENCH
SCALE: NTS
1
9
3
8
7
6
4
2
5
24"18"
6"
PLAN
10'
1/4" DISTRIBUTION TUBING. RUN
TUBING UNDER WEED BARRIER
FABRIC TO PLANT.
LENGTH NOT TO EXCEED 8'
UNIVERSAL 1/4" STAKE
DIFFUSER CAP
TOP OF MULCH
PRESSURE COMPENSATING
EMITTER PER EMITTER
SCHEDULE. INSTALL EMITTER
AT 45° TO 60° ANGLE
3/4" POLYETHYLENE TUBING
SET WITH TOP OF TUBING
FLUSH WITH FINISH GRADE OF
SOIL
FINISH GRADE OF SOIL
WEED BARRIER FABRIC
1
2
3
4
5
6
7
8
SINGLE OUTLET EMITTER
SCALE: NTS
1
2
3
4
7
5
6
8
SINGLE OUTLET EMITTER PLACEMENT
SCALE: NTS
DIFFUSER CAP W/ DRIP STAKE
PLANT CENTER
PLANT ROOTBALL
SINGLE OUTLET EMITTER
3/4" POLYETHYLENE DRIP TUBING
1/4" DISTRIBUTION TUBING
(LENGTH NOT TO EXCEED 8')
1
2
3
4
5
6
NOTE:
1.EMITTERS SHALL BE EQUALLY SPACED AROUND ROOTBALL.
2.FLUSH ALL LINES THOROUGHLY PRIOR TO EMITTER INSTALLATION.
2.IF PLANTING ON A 4:1 SLOPE OR STEEPER, INSTALL EMITTERS ON THE UPHILL SIDE OF PLANT.
3.EMITTERS SHALL BE SELF-FLUSHING PRESSURE COMPENSATING-TYPE UNLESS NOTED
OTHERWISE.
4.DRIP VALVE ZONES (HYDROZONES) ARE DESIGNED TO ACCOUNT FOR DIFFERENCES IN PLANT
REQUIREMENTS AND SUN EXPOSURE.
5.CONTRACTOR SHALL ENSURE HYDROZONES ARE VALVED SEPARATELY AS SHOWN ON PLAN.
1
2
3
4
5
6
1
3
6
56
EMISSION POINT. DIFFUSER CAP
W/ DRIP STAKE (TYP.)
PLANT ROOT BALL (TYP.)
PLANT CENTER (TYP.)
SECOND EMISSION POINTS SEE
NOTE 3 BELOW
TREE TRUNK
MULCH LAYER
1/4" DISTRIBUTION TUBING
(LENGTH NOT TO EXCEED 8')
3/4" POLYETHYLENE DRIP TUBING
SINGLE OUTLET EMITTER
ROOTBALL
1
2
3
4
5
6
7
8
9
10
TREE EMITTER PLACEMENT
SCALE: NTS
60°60°
60°
6
0
°60°NOTE:
1.MAXIMUM LENGTH OF ONE DISTRIBUTION TUBE SHALL BE 8'.
2.ALL EMISSION POINTS SHALL BE LOCATED ON UPHILL SIDE OF PLANT MATERIAL. ONE
EMISSION POINT SHALL BE DIRECTLY TO PLANT BALL AS INDICATED. ADDITIONAL EMISSION
POINTS SHALL BE WITHIN PLANT PIT PERIMETER AS DIRECTED IN THE EMITTER SCHEDULE.
3.SECOND EMISSION POINTS (IF NEEDED) AS PER THE EMITTER SCHEDULE FOR TREES WITH 3"
CALIPER OR GREATER OR CONIFEROUS TREES 10' OR GREATER IN HEIGHT.
4.THIS IS A WATERING GUIDE ONLY. SITE, SOIL AND PLANT CONDITIONS VARY GREATLY.
CONTRACTOR MUST OBSERVE THE PLANT MATERIAL AND MAKE ADJUSTMENTS AS
NECESSARY FOR PROPER PLANT WATER REQUIREMENT.
1
2
3
4
5
1
6
7
8
9
10
6" MIN.
12" MAX.
8
7
10
NOTE:
1.COMPACT SOIL AROUND VALVE BOX TO THE SAME DENSITY AS ADJACENT UNDISTURBED
SUBGRADE.
2.SECURE STAKE TO FLUSH END CAP OR PVC NIPPLE WITH A MIN. OF 2 HOSE CLAMPS.
3.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
1
7
2
8
3
9
4
5
6
4" POP-UP HEAD WITH ENCLOSED
NOZZLE AND SWING PIPE. (ZONE
OPERATIONAL INDICATOR)
LOCKING ROUND BOX & COVER
PER SCHEDULE. TOP OF BOX TO
BE FLUSH WITH FINISH GRADE
HOSE END SELF FLUSH CAP
FINISH GRADE
24" #4 REBAR TO HOLD END CAP
IN PLACE W/ (2) STAINLESS STEEL
HOSE CLAMPS
3/4" POLYETHYLENE DRIP TUBING
ELBOW COMPRESSION FITTING
3/4" GRAVEL SUMP, 4" DEPTH
BRICK (2 REQUIRED MIN.)
RISER (LENGTH AS NEEDED)
COMPRESSION TEE W/ POLY TO
PVC ADAPTER
PVC LATERAL
1
2
3
4
5
6
7
8
9
10
11
12
DRIP FLUSH END CAP WITH INDICATOR
SCALE: NTS2"MIN.10
11
12
1
4
7
2
5
8
3
6
IRRIGATION
DETAILS
LI501
OWNER:
DATE:
SHEET TITLE:CHECKED BY:DRAWN BY:TOWNEPLACE SUITES HOTEL - BOZEMAN WESTSITE PLAN DESIGNNORTHEAST CORNER OF N27TH AVE AND HONOR LANE | BOZEMAN, MT.BRAXTON DEVELOPMENT
1735 S. 19TH AVE. SUITE B
BOZEMAN, MT 59718
406.582.8100
JB, REJS01/25/23: SITE PLAN
06/09/23: SITE PLAN
R
1101 Bannock Street
Denver, CO 80204
P 303.892.1166