HomeMy WebLinkAbout046 Towneplace Suites - Landscape Irrigation DetailsIRRIGATION CONTROLLER
BUILDING WALL
PROVIDE THROUGH WALL
CONDUIT
CONDUIT 90° JUNCTION BOX
THROUGH WALL (BOTH SIDES)
FINISH GRADE
UF DIRECT BURIAL WIRE TO
REMOTE CONTROL VALVES
BUILDING WALL
WALL MOUNT CONTROLLER AT
EYE-LEVEL INSTALL PER
MANUFACTURER'S
RECOMMENDATIONS
SCH. 80 PVC OR RIGID STEEL
CONDUIT FOR CONTROL WIRES
AND GROUNDING
120 VAC POWER SUPPLY
JUNCTION BOX
FINISH FLOOR
MOUNT SENSOR RECEIVER
ADJACENT TO CONTROLLER
1
2
3
4
5
6
7
8
9
10
11
12
VARIES
OPEN
SIDE VIEW FRONT VIEW
NOTE:
1.ALL ELECTRICAL MATERIALS SHALL BE U.L. APPROVED FOR USE AS SHOWN.
2.ALL ELECTRICAL AND CONTROLLER WIRE TO BE INSTALLED PER LOCAL CODE AND
MANUFACTURER'S SPECIFICATIONS.
3.GROUND CONTROLLER PER LOCAL CODE AND MANUFACTURER'S SPECIFICATIONS.
4.PROVIDE WATERPROOF SEALANT FOR ALL CONDUIT AND WIRE ACCESS POINTS.
5' MIN.
1
2
3
5
6
7
8
9
10
4
11
4
12
CONTROLLER WALL MOUNT INTERIOR
SCALE: NTS
NOTE:
1.INSTALL PER MANUFACTURER'S SPECIFICATIONS.
2.SLOPE TOP OF FOOTER AWAY FROM POLE.
3.FINAL LOCATION AND MOUNTING SYSTEM TO BE APPROVED BY OWNER.
4.SENSOR SHOULD NOT BE MOUNTED UNDER TREES, IN AREAS AFFECTED BY SPRINKLER
SYSTEM OR UNDER EAVE OF HOUSE.36" MIN.12" MIN.12" DIA.
1
2
3
4 10' MIN.RAIN SENSOR POLE MOUNT
NTS
WIRELESS RAIN SENSOR,
LOCATE WITHIN 500' OF THE
CONTROLLER.
2" SQ., 12 GUAGE GALVANIZED
STEEL POST. COLOR TO BE
POWDERCOAT BLACK
CONCRETE BASE-FORM WITH
SONOTUBE OR EQ. POST
SHALL BE CENTERED WITHIN
BASE. ALL CONCERET SHALL
HAVE A MINIMUM
COMPRESSIVE STRENGTH OF
4,000 PSI AT 28 DAYS OR PER
SOILS REPORT.
COMPACTED SUBGRADE
1
2
3
4
4
3
2
1
NOTE:
1.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
2.LOCATE DRAIN VALVE AT POINT OF CONNECTION AND AT ALL LOW POINT(S) ALONG THE
IRRIGATION MAINLINE AS NEEDED.
5
6
7
8
9
10
11
12
13
MANUAL DRAIN VALVE
SCALE: NTS
10" LOCKING ROUND BOX &
COVER PER SCHEDULE. TOP OF
BOX TO BE FLUSH WITH FINISH
GRADE.
2" VALVE MARKER
2" CL160 PVC ACCESS SLEEVE
LENGTH AS REQUIRED.
3" DEPTH 3/4" CRUSHED GRAVEL
6" BEYOND EDGE OF BOX
PVC PRESSURE MAIN LINE
SCH. 80 TEE PER MAINLINE SIZE.
ALIGN IN A DOWNWARD POSITION
SCH. 80 PVC NIPPLE
FINISH GRADE
1" BRONZE STOP VALVE WITH
SLOTTED KEY OPERATOR
SCH. 80 PVC ELL
SCH. 80 PVC NIPPLE
3/4" GRAVEL SUMP - 1 CU. FT. MIN
SOIL BLANKET ENCLOSING SUMP
AMOCO ENG. FABRIC 4545 - 4.5
OZ. OR EQUAL
1
2
3
4
5
6
7
8
9
10
11
12
13
PVC MAINLINE
SCH. 80 PVC MALE ADAPTER
SCH. 80 PVC BALL VALVE
FINISH GRADE
LOCKING VALVE BOX
SCH. 80 PVC NIPPLE
(THREADED)
MASTER VALVE
SCH. 80 PVC UNION
(THREADED)
WATERPROOF ELECTRICAL
CONNECTIONS
WIRES TO CONTROLLER
BRICK SUPPORTS 2 MIN.
3/4" GRAVEL SUMP - 8" DEPTH
COMPACTED SUBGRADE
1
2
3
4
5
6
7
8
9
10
11
12
13
3" MIN.
MASTER VALVE
SCALE: NTS
NOTE:
1.INSTALL MASTER VALVE PER MANUFACTURER'S SPECIFICATIONS FOR WIRING AND
GROUNDING.
4
1
2
3
5 6 7 8 9 10 1
11 12 13 26
MINIMUM UPSTREAM
DISTANCE 10x
FLOW METER SIZE
OF CLEAN STRAIGHT PIPE
MINIMUM DOWNSTREAM
DISTANCE 5x
FLOW METER SIZE
OF CLEAN STRAIGHT PIPE
FLOW
WIRES TO CONTROLLER
LOCKING VALVE BOX
WATERPROOF ELECTRICAL
CONNECTIONS
FLOW SENSOR PER SCHEDULE
DOWNSIZED MAINLINE
FINISH GRADE
SCH. 80 PVC ECCENTRIC
COUPLING (S x S) - SIZE & QTY
TO BE DETERMINED IN FIELD
SCH. 80 PVC NIPPLE (MPTxS)
SCH. 80 PVC UNION
(THREADED)
PVC MAINLINE
SCH. 80 PVC MALE ADAPTER
COMPACTED SUBGRADE
3/4" GRAVEL SUMP 8" DEPTH
BRICK SUPPORTS 2 MIN.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
FLOW SENSOR
SCALE: NTS
NOTE:
1.INSTALL FLOW SENSOR PER MANUFACTURER'S SPECIFICATIONS FOR WIRING AND
GROUNDING.
2 3 4 5 6 7 9
12
13
14
8 1010987
1111
1
LOCKING ROUND BOX & COVER
PER SCHEDULE. TOP OF BOX
TO BE FLUSH WITH FINISH
GRADE
FINISH GRADE
8" SCH 40 PVC ACCESS SLEEVE
LENGTH AS REQUIRED.
GATE VALVE W/ CROSS
HANDLE AND SOLID WEDGE
DISC PER SCHEDULE
3/4" GRAVEL SUMP FILL IN AND
AROUND BOX AS REQUIRED.
3" DEPTH 3/4: GRAVEL EXTEND
6" BEYOND EDGE OF BOX
PVC MAINLINE
COMPACTED SUBGRADE
1
2
3
4
5
6
7
8
NOTE:
1.COMPACT SOIL AROUND GATE VALVE ASSEMBLY TO THE SAME DENSITY AS ADJACENT
UNDISTURBED SUBGRADE.
2.DO NOT REST VALVE BOX OR ACCESS SLEEVES ON MAINLINE OR LATERAL LINE.
3.PROVIDE GATE VALVE KEY - LENGTH AS REQUIRED.
CL
GATE VALVE 2" AND SMALLER
SCALE: NTS4" MIN.2"MIN.SEE TRENCHING DETAILFOR PIPE DEPTH4
3
2
1
6
7
5
8
FINISH GRADE
10" ROUND BOX & COVER PER
SCHEDULE. TOP OF BOX TO
FLUSH WITH FINISH GRADE
QUICK COUPLING VALVE W/
LOCKING COVER PER
SCHEDULE
SCH. 80 PVC RISER (T x T)
3" DEPTH 3/4" GRAVEL BASE
EXTEND 6" BEYOND EDGE OF
BOX
PVC SWING JOINT
PVC MAINLINE
24" LONG #4 REBAR TO HOLD
QUICK COUPLER IN PLACE W/
(2) STAINLESS STEEL CLAMPS
1
2
3
4
5
6
7
8
QUICK COUPLER
SCALE: NTS
NOTES:
1.EACH QUICK COUPLER SHALL BE IN A SEPARATE VALVE BOX.
2.PROVIDE (1) QUICK COUPLER KEY FOR EACH QUICK COUPLER VALVE.
3.QUICK COUPLER SHALL HAVE LOCKING RUBBER COVER. COLOR PER LEGEND.
4.COMPACT SOIL AROUND GATE VALVE ASSEMBLY TO THE SAME DENSITY
AS ADJACENT UNDISTURBED SUB-GRADE.
5.ALL THREADED CONNECTIONS SHALL BE COATED WITH TEFLON TAPE.
1
2
3
4
5
6
7
8
1
4
7
2
5
8
3
6
9
PVC MAINLINE
BRICK SUPPORT (4 MIN.)
CONTROL WIRE
COMMON WIRE TO NEXT
VALVE(S)
PVC LATERAL
PVC MALE ADAPTER
SCH. 80 PVC UNION
(THREADED)
WATERPROOF CONNECTORS
(4) SCH. 80 PVC NIPPLE/ RISER
(SIZE & LENGTH VARY)
CONTROL VALVE
SCH. 80 PVC BALL VALVE
LOCKING VALVE BOX
FINISH GRADE
PVC ELBOW (TxT)
3/4" GRAVEL SUMP - 4" DEPTH
PVC TEE (SxSxT)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
3"
FLOW
NOTE:
1.INSTAL CONTROL VALVE PER MANUFACTURER'S RECOMMENDATIONS.
CONTROL VALVE
SCALE: NTS
12
13
14
15
3
7
1
6
5
3
2
4
8 9 10 11
16
9
3"
FLOW
WATERPROOF CONNECTORS
30" COIL OF WIRE MINIMUM.
PLACED IN BOX.
(2) SCH. 80 PVC UNION
(THREADED)
PVC COUPLING (FPTxFPT)
PVC LATERAL
BRICK SUPPORT (4 MIN)
4" DEPTH GRAVEL SUMP
VALVE BOX PER LEGEND,
FLUSH TOP OF BOX W/
GRADE
CONTROL VALVE PER
LEGEND
SCH. 80 PVC BALL VALVE
CONTROL AND COMMON
WIRES FROM CONTROLLER
SCH. 80 PVC TEE (SxSxT)
PVC MAINLINE
1
2
3
4
5
6
7
8
9
10
11
12
13DRIP CONTROL ZONE KIT
SCALE: NTS
NOTES:
1.BUNDLE & TAPE WIRE EVERY 10 FT. SEAL
WIRE ENDS WITH WATERPROOF SPLICING
MATERIAL.
2.30" MINIMUM LENGTH OF CONTROL WIRE
COILED AND PLACED IN BOX AT WATER
PROOF CONNECTION TO SOLENOID.
3.INSTALL DRIP CONTROL ZONE KIT PER
MANUFACTURER'S SPECIFICATIONS FOR
WIRING
Drip valve to poly connection
Refer to legend for type of connection required.
POLY PVC TO POLY
FITTING
Drip valve to pvc connection
Refer to legend for type of
connection required.
1
2
3
4
5
9
10
11
12
13
6
8
7
IRRIGATION
DETAILS
LI500
OWNER:
DATE:
SHEET TITLE:CHECKED BY:DRAWN BY:TOWNEPLACE SUITES HOTEL - BOZEMAN WESTSITE PLAN DESIGNNORTHEAST CORNER OF N27TH AVE AND HONOR LANE | BOZEMAN, MT.BRAXTON DEVELOPMENT
1735 S. 19TH AVE. SUITE B
BOZEMAN, MT 59718
406.582.8100
JB, REJS01/25/23: SITE PLAN
06/09/23: SITE PLAN
R
1101 Bannock Street
Denver, CO 80204
P 303.892.1166
www.norris-design.com