Loading...
HomeMy WebLinkAbout014 RTank System DetailsGRASS SURFACE SIDE BACKFILL: 24" MIN. OF FREE DRAINING BACKFILL (SPEC SECTION 2.03B): STONE <1.5” OR SOIL (USCS CLASS GW, GP, SW OR SP). MUST BE FREE FROM LUMPS, DEBRIS AND OTHER SHARP OBJECTS. SPREAD EVENLY TO PREVENT R-TANKHD MOVEMENT. COMPACT SIDE BACKFILL WITH POWERED MECHANICAL COMPACTOR IN 12" LIFTS. COVER FROM FINISH GRADE TO TOP OF TANK: OPTIONAL OVERFLOW PIPE OPTIONAL OUTLET PIPE 4" (0.10 m) MIN. INLET PIPE BACKFILL COMPACTED TO 95% STANDARD PROCTOR DENSITY. TOTAL HEIGHT OF BACKFILL SHOULD NOT EXCEED 6.99'. 12" (0.30 m) MIN. 6.99' (2.13 m) MAX. NOTES: 1.FOR COMPLETE MODULE DATA, SEE APPROPRIATE R-TANKHD SHEET (MINI MODULE, SINGLE MODULE, DOUBLE MODULE, TRIPLE MODULE, QUAD MODULE, OR PENTA MODULE). 2.PRE-TREATMENT STRUCTURES NOT SHOWN. 3.FOR INFILTRATION APPLICATIONS, GEOTEXTILE ENVELOPING R-TANK SHALL BE ACF M200 (PER SPEC SECTION 2.02A) AND BASE SHALL BE 4" MIN. UNCOMPACTED FREE DRAINING BACKFILL (SPEC SECTION 2.03A) TO PROVIDE A LEVEL BASE. SURFACE MUST BE SMOOTH, FREE OF LUMPS OR DEBRIS, AND EXTEND 2' BEYOND R-TANKHD FOOTPRINT. R-TANKHD GREEN SPACE - SECTION VIEW 24" (0.61 m) UTILITY MARKERS AT CORNERS (TYP.) BASE: 3" MIN. FREE DRAINING BACKFILL (SPEC SECTION 2.03B) COMPACTED TO 95% STANDARD PROCTOR DENSITY IS REQUIRED TO PROVIDE A LEVEL BASE SURFACE. MUST BE SMOOTH, FREE OF LUMPS OR DEBRIS, AND EXTEND 2' BEYOND R-TANKHD FOOTPRINT. A BEARING CAPACITY OF 2,000 PSF MUST BE ACHIEVED PRIOR TO INSTALLING R-TANKHD. NATIVE SOILS MAY BE ACCEPTABLE IF DETERMINED TO BE STABLE BY OWNER'S ENGINEER. (SEE NOTE #3) R-TANKHD UNITS LOAD RATING: 33.4 PSI (MODULE ONLY) SUBGRADE / EXCAVATION LINE: COMPACT PER SPEC SECTION 3.02 D. A BEARING CAPACITY OF 2,000 PSF MUST BE ACHIEVED PRIOR TO INSTALLING R-TANKHD R-TANK SYSTEM B A SIZE A B 23" x 24"23"26.51" 28" x 30"28"33.15" 34" x 36"34"38.69" ±0.25" TOLERANCE ON DIMENSIONS Ø0.38" TYP. Ø0.38" TYP. 2.00" 2.00" 5.00" Ø0.75" TYP. 1.00" SPACING REF. 2.00" SPACING REF. Ø0.38" TYP. 6.49" REF. 1.00" TYP. TRASHGUARD PLUS PRETREATMENT DETAIL DRAWN BY SHEET NO. TDS 6FOR ADDITIONAL INFORMATION PLEASE CONTACT:ACF WEST, 1-800-423-4567, www.acfwest.com01/09/2023 ENGINEER OF RECORD TO REVIEW, APPROVEAND ENDORSE FINAL SITE SPECIFIC DESIGN.of DATE 23-001MT ACF WEST PROJECT NUMBER 4R-TANKHD SYSTEM DETAILSTPS-FFISBOZEMAN, MTSITE DESIGNATION: UGDSNOTES 1.THIS PORT IS USED TO PUMP WATER INTO THE SYSTEM AND RE-SUSPEND ACCUMULATED SEDIMENT SO THAT IT MAY BE PUMPED OUT. 2.MINIMUM REQUIRED MAINTENANCE INCLUDES A QUARTERLY INSPECTION DURING THE FIRST YEAR OF OPERATION AND A YEARLY INSPECTION THEREAFTER. FLUSH AS NEEDED. 3.R-TANKHD, R-TANKSD, R-TANKUD AND R-TANKXD MAY BE USED IN TRAFFIC APPLICATIONS. 4.SEE TRAFFIC LOADING DETAIL FOR MINIMUM & MAXIMUM COVER REQUIREMENTS. 5.IF MAINTENANCE PORT IS LOCATED IN A NON-TRAFFIC AREA, A PLASTIC CAP CAN BE USED IN LIEU OF A FRAME AND COVER WITH CONCRETE COLLAR. 16.25" FRAME AND COVER NON-CORROSIVE SOLID PLATE PLASTIC, SLATE OR EQUIVALENT BACKFILL COMPACTED TO 95% STANDARD PROCTOR DENSITY PIPE NOTCHING PATTERN 1.5"3.5"8" NOTCHES CUT IN SHADED AREAS (8 OPENINGS TOTAL) R-TANKHD TYPICAL MAINTENANCE PORT NOTCH BOTTOM OF PIPE (SEE PATTERN) 12" DIA. PVC MAINTENANCE PORT LANDSCAPED SURFACE REINFORCED CONCRETE COLLAR (WHERE REQUIRED), MIN. 1" CLEARANCE FROM PVC GEOTEXTILE (AS SPECIFIED) 1" +/- VENTING PERFORATIONS NON-CORROSIVE HOSE CLAMP R-TANKHD MODULE (SEE MODULE DETAIL FOR ACTUAL HEIGHT)R-TANK HD SYSTEM