Loading...
HomeMy WebLinkAbout029 E101 Site PlanM E5 E5 E5 E2 E1 E1 E5 E11 E11 E5 E5 E5 E12 E14 E14 E15 E15 E14 E2 E2 1 2 E10 E10 E14 (R) HHA (R) HLC 34 5 6 7 8 IRRIGATION WELL PUMP HLC-31,33 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13 HHA-13HHA-13 9 9 9 10 11 11 11 HHA-13 HHA-13 PHASE I 12 12 GENERAL ELECTRICAL NOTES A. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS. B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER. C. LOW VOLTAGE CABLES (LIGHTING CONTROLS) ABOVE ACCESSIBLE CEILINGS SHALL BE SUPPORTED USING J-HOOKS AT INTERVALS NOT TO EXCEED 48" OC, UNO. THESE DOCUMENTS, IN PART OR IN WHOLE, AND THEDESIGN THEY REPRESENT ARE THE SOLE PROPERTYOF COLLABORATIVE DESIGN ARCHITECTS. THESEDOCUMENTS ARE INTENDED FOR THE PROJECT ONTHE SITE INDICATED. ANY USE, REPRODUCTION,MODIFICATION OR ADAPTATION WITHOUT THEEXPRESS WRITTEN CONSENT OF COLLABORATIVEDESIGN ARCHITECTS IS STRICTLY PROHIBITED.2280 GRANT ROAD, SUITE C BILLINGS, MT 59102 406.248.3443PREPARED FOR:PROJECT NUMBER:PROJECT ARCHITECT: GALLATIN CROSSING MASTER SITE PLAN SUBMITTAL 2825 WEST MAIN STREET, BOZEMAN MT 59718 GALLATIN MALL GROUP JEFF KANNING 2206.?C O L L A B O R A T I V ED E S I G N A R C HITE CTSISSUE DATES:2205-GALLATIN CROSSING MASTER SITE PLAN SUBMITTALCOPYRIGHT C 2022 www.cd-mt.com406.656.6000 315 N. 25th Street, Suite 102, Billings, MT 59101 www.m-m.net#IssueDate #RevID - - -A SCTEIR C H T 5/26/2023 - ADD. #1 E101 ELECTRICAL SITE PLAN - PHASE I MMI Project #: 2581.040 5/20/2022 MASTER SITE PLAN SUBMITTAL 5/20/2022 MASTER SITE PLAN SUBMITTAL 1" = 30'-0"E101 1 ELECTRICAL SITE PLAN - PHASE I 1 APPROXIMATE LOCATION OF EXISTING PANELS HHA & HLC. 2 EXISTING SITE LIGHT TO REMAIN. 3 EXISTING SITE LIGHT TO BE DEMOLISHED. 4 DEMOLISH EXISTING CIRCUITS AND CONDUIT BETWEEN SITE LIGHTS AS SHOWN. 5 DEMOLISH EXISTING CIRCUITS AND CONDUIT BETWEEN SITE LIGHT AND NEW ELECTRIC HANDHOLE AS SHOWN. 6 PROVIDE NEW ELECTRIC HANDHOLE. COORDINATE LOCATION WITH EXISTING CONDUIT RUN SERVING EXISTING SITE LIGHTING. SEE DETAIL 3 ON E002. 7 PROVIDE NEW 2" CONDUIT BETWEEN EXISTING SITE LIGHT AND NEW ELECTRIC HANDHOLE AS SHOWN. COORDINATE ROUTING WITH CIVIL DRAWING. FIELD VERIFY EXISTING CONDUCTOR SIZE AND QUANTITY AND MATCH ACCORDINGLY. 8 PORTION OF EXISTING CONDUIT FROM PANEL TO NEW ELECTRIC HANDHOLE TO REMAIN. FIELD VERIFY EXACT LOCATION. 9 APPROXIMATE LOCATION OF EXISTING SITE LIGHT TO BE DEMOLISHED. DEMOLISH EXISTING CONDUCTORS AND CONDUIT TO NEAREST UPSTREAM JUNCTION BOX OR PANEL. 10 PROVIDE CIRCUIT CONSISTING OF 1-1/4"C, 2#8CU, #8NCU, #10GCU. 11 PROVIDE #10CU CONDUCTORS IN 1" CONDUIT FOR SITE LIGHTING CIRCUIT. TYPICAL FOR EACH SITE LIGHTING CIRCUIT. 12 PROVIDE ELECTRIC HANDHOLE. SEE DETAIL 3 ON E002. KEY NOTES:# IS SEFORP LANO E N G INEERO NTM ANA LICENS E D JEFFREY L. KRAFT No. 12720 PE