Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
070 E502 - Electrical Schedules
CLUBHOUSE LUMINAIRE SCHEDULE LUMINAIRE LUMINAIRE LUMINAIRE DESCRIPTION LAMPS LUMINAIRE REMARKSNUMBER MANUFACTURER CATALOG #TYPE CCT VOLTS WATTS MOUNTING CD1 OWNER PROVIDED OWNER PROVIDED 4-IN. DOWNLIGHT DIMMABLE, WET RATED LED 1,000 LUMEN 3000K 120 15 MAX RECESSED FOR LIGHTS LABELED 'EM', PROVIDE AN EMERGENCY BATTERY PACK FIXTURE AND FINISHES ARE OWNER PROVIDED COORDINATE WITH ARCHITECT PRIOR TO PURCHASE CL1 CORONET LS3 UPDN-4-30-LOW-MED-UNV- DB-SCBA-AC-AVI-BAT-FL-SCBA 4-FT. SUSPENDED LINEAR DIRECT/INDIRECT LED 2,156 LUMEN UP/ 2,664 LUMEN DOWN 3000K 120 48 SUSPENDED FINAL FINISH BY ARCHITECT/OWNER CL2 OWNER PROVIDED OWNER PROVIDED 2-FT STRIP LIGHT W/ EM BATTERY PACK LED 1,200 LUMEN 4000K 120 15 MAX SURFACE FIXTURE AND FINISHES ARE OWNER PROVIDED COORDINATE WITH ARCHITECT PRIOR TO PURCHASE CL3 OWNER PROVIDED OWNER PROVIDED 4-FT STRIP LIGHT LED 2,400 LUMEN 4000K 120 30 MAX SURFACE FIXTURE AND FINISHES ARE OWNER PROVIDED COORDINATE WITH ARCHITECT PRIOR TO PURCHASE CL4 HERMAN MILLER ODE LAMP, 33" SURFACE INTEGRATED LAMP, 33-IN HEIGHT MOUNTED TO PARTITION LED 3500K 120 6 SURFACE FINAL FINISH BY ARCHITECT/OWNER CP1 OCL GB1-P1FE-04-FS-SCBA-LED1-30K-UNV-48"-DM1 KITCHEN ISLAND PENDANTS 4.5-IN DIA. LED 635 LUMEN 3000K 120 8 SUSPENDED FINAL FINISH BY ARCHITECT/OWNER CP2 OCL AO2-P2DB-48-MW-SCBA-LED1-30K-UNV-60"-DM1 3-RING STAIRWELL PENDANT 2FT, 3FT, 4FT DIA. RINGS LED 6,240 LUMEN 3000K 120 105 SUSPENDED FINAL FINISH BY ARCHITECT/OWNER CP3 FABBIAN F07A05A01 DIFFUSER PENDANT, BLOWN GLASS BOOTHS LED 3000K 120 50 SUSPENDED FINAL FINISH BY ARCHITECT/OWNER CS1 ARANCIA W66-32-LW-A-U-0-JB-BK 32" WALL SCONCE, MATTE BLACK 0-10V DIMMING LED 1,800 LUMEN 3000K 120 15 WALL CT1 OWNER PROVIDED OWNER PROVIDED COVE LIGHT IN SOFFIT LED 3000K 120 3W/FT COVE FIXTURE AND FINISHES ARE OWNER PROVIDED COORDINATE WITH ARCHITECT PRIOR TO PURCHASE SEE PLANS FOR LENGTH CV1 MAJESTIC MIRROR STRAND XL - 28" W X 42" H BACK-LIT MIRROR LED 3000K 120 56 WALL PROVIDE AN APPROPRIATE DRIVER AS NECESSARY CW1 OWNER PROVIDED XTOR6BRL-Y WALL-MOUNT FIXTURE, REFRAC. LENS WET LOCATION RATED LED 5,817 LUMEN 3000K 120 58 WALL FINAL FINISH BY ARCHITECT/OWNER CW2 COOPER LIGHTING XTOR8BRL-Y WALL-MOUNT FIXTURE, REFRAC. LENS WET LOCATION RATED LED 8,066 LUMEN 3000K 120 81 WALL FINAL FINISH BY ARCHITECT/OWNER WS1 COOPER LIGHTING 9002-W1-[RW,RI]-LED2790-S-SCBA- L1-UNV WALL-MOUNT FIXTURE, RECESSED LENS WET LOCATION RATED LED 356 LUMEN 3000K 120 10 WALL FINAL FINISH BY ARCHITECT/OWNER EX1 OWNER PROVIDED OWNER PROVIDED DIE-CST ALUMINUM ALLOY SINGLE-FACE WHITE EXIT SIGN WITH EMERGENCY BATTERY PACK GREEN LED N/A 120 1.5 UNIVERSAL FIXTURE AND FINISHES ARE OWNER PROVIDED COORDINATE WITH ARCHITECT PRIOR TO PURCHASE SCHEDULE: LIGHTING SWITCHES TAG DESCRIPTION FUNCTION REMARKS LV2 LOW-VOLTAGE SWITCH FOR LIGHTING CONTROL PANEL 'LCP'ON / OFF / RAISE / LOWER OS1 OCCUPANCY / VACANCY WALL SWITCH SENSOR MANUAL ON / AUTO OFF 30-MINUTE VACANCY TIMEOUT OS2 OCCUPANCY / VACANCY DIMMABLE WALL SWITCH SENSOR MANUAL ON / AUTO OFF / RAISE / LOWER 20-MINUTE VACANCY TIMEOUT 0-10V DIMMING OS4 OCCUPANCY / VACANCY CEILING SENSOR MANUAL ON / AUTO OFF 20-MINUTE VACANCY TIMEOUT PROVIDE WITH 0-10V DIMMING POWER PACK OS4A LOW-VOLTAGE SWITCH FOR 'OS4' WITH DIMMING CONTROLS ON / OFF / RAISE / LOWER GENERAL NOTE: ELECTRICAL CONTRACTOR SHALL CONFIRM DEVICE COMPATIBILITY WITH LUMINAIRES, LIGHTING CONTROL PANEL(S), ROOM CONTROLLER(S), AND OTHER EQUIPMENT. ANY DESIGN DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ELECTRICAL ENGINEER IMMEDIATELY. SITE LUMINAIRE SCHEDULE LUMINAIRE LAMPS POLE REMARKSNUMBER MANUFACTURER CATALOG # / DESCRIPTION VOLTS #/POLE WATTS MOUNTING TYPE QTY. MANUFACTURER HEIGHT CATALOG # A12 OWNER PROVIDED AREA LIGHT; OWNER PROVIDED; LED-20-100W-30-SCBA-120-277V-NO PHOTOCELL-TYPE 3-STRAIGHT ARM 120-277 1 40.4 POLE LED 6804 LUMEN 3000K CCT 1 - SEE SITE PLAN - SET FIXTURE TO 40W OPTION FINISH BY ARCHITECT/OWNER POLE IS OWNER PROVIDED SM6 COOPER LIGHTING HALO SMD6R12930WH 6-IN ROUND SURFACE MOUNT 120 N/A 10 SURFACE LED 1200 LUMEN 1 N/A N/A N/A SCHEDULE: LIGHTING CONTROL PANEL NAME: LCP1 POWER SUPPLY CIRCUIT: A1-20 MOUNTING: FLUSH NUMBER OF RELAYS: 32 ENCLOSURE: NEMA 1 LOCATION: CLUBHOUSE JANITOR'S CLOSET RELAY SUPPLY CIRCUIT AREA SERVED LV SWITCH (SEE SWITCH SCHEDULE) CONTROL CODE REMARKSNUMBER AMP POLE 1 20 1 A1-2 RECEPTION LV-a A(D)1 2 20 1 A1-2 L1 HALLWAY LV-b A(D)1 3 20 1 A1-2 STAIRS DOWNLIGHTS LV-c A(D)1 4 20 1 A1-2 STAIRS PENDANT LV-d A(D)1 5 20 1 A1-6 GAME LOUNGE DOWNLIGHTS LV-e A(D)1 6 20 1 A1-6 GAME LOUNGE PENDANTS LV-f A(D)1 7 20 1 A1-6 G.L. BOOTH PENDANTS LV-g A(D)1 8 20 1 A1-6 G.L. BOOTH SCONCES LV-h A(D)1 9 20 1 A1-6 FITNESS DOWNLIGHTS LV-i B(D)6 10 20 1 SPARE 11 20 1 A1-6 G.L. DOWNLIGHTS LV-j A(D)1 12 20 1 A1-10 STAIRS DOWNLIGHTS LV-k A(D)1 13 20 1 A1-10 STAIRS PENDANT LV-l A(D)1 14 20 1 A1-10 UPPER LOUNGE DOWNLIGHTS LV-m A(D)1 15 20 1 A1-10 UPPER LOUNGE LINEARS LV-n A(D)1 16 20 1 A1-10 STUDY LOUNGE LAMPS LV-o A(D)1 17 20 1 A1-10 UPPER LOUNGE COVE LTG LV-p A(D)1 18 20 1 A1-10 L2 FITNESS LINEARS LV-q B(D)6 19 20 1 A1-10 L2 FITNESS DOWNLIGHTS LV-r B(D)6 20 20 1 SPARE 21 20 1 A1-12 CLUBHOUSE EXTERIOR N/A E(D)1 22 20 1 A1-14 LTG - SITE N/A E(D)2 REDUCE LIGHTING BY 50% FROM 12AM TO 6AM23 20 1 A1-16 LTG - SITE N/A E(D)2 24 20 1 A1-18 MONUMENT SIGN N/A C(D)3 25 20 1 SPARE 26 20 1 SPARE 27 20 1 SPARE 28 20 1 SPARE 29 20 1 SPARE 30 20 1 SPARE 31 20 1 SPARE 32 20 1 SPARE PROGRAM CODE:A AUTO ON / AUTO OFF 1 HOURS OF OPERATION B MANUAL ON / AUTO OFF 2 DUSK TO DAWN (C)ASTRONOMIC TIMECLOCK 3 CUSTOM TIMES (D)DIMMING RELAY 4 OFF AFTER X MINUTES (E)PHOTOCELL 5 OFF AT DUSK 6 OFF AT CUSTOM TIME GENERAL NOTES: A. SEE PLAN(S) FOR LOCATION(S) OF LOW VOLTAGE SWITCH(ES). B. RELAY TO CONTROL COIL OF 2-POLE CONTACTOR, FACTORY MOUNTED ON CABINET INTERIOR. C. ELECTRICAL CONTRACTOR TO PROVIDE SPACE IN THIS PANEL FOR FUTURE EXPANSION. D. INSTALL VOLTAGE BARRIERS AS REQUIRED BY LOCAL AHJ OR TO SEPARATE NORMAL AND EMERGENCY POWER CIRCUITS. E. CONFIRM PROGRAMMING WITH OWNER PRIOR TO COMMISSIONING THE LIGHTING CONTROL SYSTEM. EQUIPMENT SCHEDULE UNIT # EQUIPMENT DESCRIPTION ELECTRICAL REFERENCE NOTES OCPD REMARKS LOADLOAD UNITSVOLTSPHASEFULL LOAD AMPS (FLA)DISCONNECTINGMEANSDISCONNECT RATING(AMPS)STARTER SIZEENCLOSURE TYPEFUSE SIZE(AMPS)BREAKER SIZE(AMPS)AC-1 MINI SPLIT UNIT - MAINTENANCE 240 1 1A 30 - -POWERED FROM ODU-1AC-2 MINI SPLIT UNIT - BIKE/SKI REPAIR 240 1 1A 30 - - BP-1 SNOW MELT PUMP - BOILER 1/6 HP 120 1 3.6 5A 20 - 17 - 15 RP-1 SNOW MELT PUMP - RAMP 1/6 HP 120 1 3.6 5A 20 - 17 - 15 RP-2 SNOW MELT PUMP - ENTRANCE 1/6 HP 120 1 3.6 5A 20 - 17 - 15 GF-1 GLYCOL FEEDER 0.9 FLA 120 1 0.9 6A 20 - 17 - 15 ODU-1 MINI SPLIT UNIT - BUILDING A UTILITIES 17.1 MCA 240 1 13.7 1A 30 - 18 - 20 AH-1 INDOOR AIR HANDLER - TOWN HOUSE 4.9 MCA 240 1 3.9 5A 20 - 17 - 15 32 MCA 240 1 25.6 1A 30 - 17 - 25 AH-2 INDOOR AIR HANDLER - 2 & 3 BED APT 6.5 MCA 240 1 5.2 5A 20 - 17 - 15 36 MCA 240 1 28.8 1A 30 - 17 - 40 GAH-1 GAS INDOOR AIR HANDLER - ROUGE FIT 0.5 HP 120 1 7.7 1A 30 - 17 - 15 GAH-2 GAS INDOOR AIR HANDLER - CLUBHOUSE 0.5 HP 120 1 7.7 1A 30 - 17 - 15 RC-1 REMOTE CONDENSING UNIT 15.2 MCA 240 1 12.2 1A 30 - 18 - 20 SERVES AH-1 RC-2 REMOTE CONDENSING UNIT 29.8 MCA 240 1 23.8 1A 30 - 18 - 30 SERVES AH-2 RC-3 REMOTE CONDENSING UNIT 17 MCA 240 1 13.6 1A 30 - 18 - 25 SERVES GAH-1 RC-4 REMOTE CONDENSING UNIT 40 MCA 240 1 32.0 1A 60 - 18 - 40 SERVES GAH-2 EF-1 EXHAUST FAN - TOWNHOUSE UNITS RR 0.39 MCA 120 1 0.3 6A 20 - 17 - 15 EF-2 EXHAUST FAN - 2 & 3 BED APT UNITS RR 0.39 MCA 120 1 0.3 6A 20 - 17 - 15 EF-3 EXHAUST FAN - KITCHEN 0.39 MCA 120 1 0.3 6A 20 - 17 - 15 EF-4 EXHAUST FAN - COMMON RESTROOM 0.39 MCA 120 1 0.3 6A 20 - 17 - 15 EF-6 EXHAUST FAN - SPA ROOM 120 1 0.0 6A 20 - 19 - 15 EF-7 EXHAUST FAN - POOL CHEM..45 MCA 120 1 0.4 6A 20 - 19 - 15 EF-8 EXHAUST FAN - CLUBHOUSE ROOF 13.8 FLA 120 1 13.8 1A 30 - 18 - 20 EUH-1 ELECTRIC UNIT HEATER - FIRE RISERS 3.3 KW 240 1 13.8 1A 30 - 17 - 20 DISCONNECT IS ONLY REQUIRED IF INTEGRAL DISCONNECT SWITCH IS NOT PROVIDED EUH-2 ELECTRIC UNIT HEATER - T.H. STAIRS 2.25 KW 240 1 9.4 1A 30 - 17* - 15 DISCONNECT IS ONLY REQUIRED IF INTEGRAL DISCONNECT SWITCH IS NOT PROVIDED *FOR EUH-2 IN SPA EQUIP. RM. PROVIDE A NEMA 4X ENCLOSURE. EUH-3 ELECTRIC UNIT HEATER - VEST./DOG WASH 4.8 KW 240 1 20.0 1A 30 - 17 - 30 DISCONNECT IS ONLY REQUIRED IF INTEGRAL DISCONNECT SWITCH IS NOT PROVIDED EWH-1 ELECTRIC WATER HEATER - APARTMENTS 4.5 KW 240 1 18.8 1A 30 - 17 - 30 EWH-2 ELECTRIC WATER HEATER - DOG WASH 1.5 KW 240 1 6.3 1A 30 - 17 - 30 EWH-3 ELECTRIC WATER HEATER - TOWN HOMES 5.5 KW 240 1 22.9 1A 30 - 17 - 30 RP-1 RECIRC PUMP 1/40 HP 120 1 0.4 A5 20 - 17 - 15 RP-2 RECIRC PUMP 1/40 HP 120 1 0.4 5A 20 - 17 - 15 DF-1.1 DESTRATIFICATION FAN - FITNESS 0.46 FLA 120 1 0.5 6A 20 - 17 - 15 DF-1.2 DESTRATIFICATION FAN - FITNESS 0.46 FLA 120 1 0.5 6A 20 - 17 - 15 DF-1.3 DESTRATIFICATION FAN - FITNESS 0.46 FLA 120 1 0.5 6A 20 - 17 - 15 DF-1.4 DESTRATIFICATION FAN - FITNESS 0.46 FLA 120 1 0.5 6A 20 - 17 - 15 S1 CIRCULATION PUMP 5 HP 240 1 28.0 1A 60 - 19 - 50 S2 JETS PUMP 3 HP 240 1 17.0 1A 30 - 19 - 30 S4 HEATER NATURAL GAS 500 W 120 1 4.2 6A 20 - 19 - 15 S5A CHEMICAL CONTROLLER 1 FLA 120 1 1.0 6A 20 - 19 - 15 S5B CHEMICAL CONTROLLER INTERLOCK 2.8 FLA 120 1 2.8 6A 20 - 19 - 15 S6 FEEDER PUMP, LIQUID CHLORINE 1/30 HP 120 1 1.0 6A 20 - 19 -15 S7 FEEDER PUMP, LIQUID ACID 1/30 HP 120 1 1.0 6A 20 - 19 - 15 S14 WATER LEVEL CONTROL SYSTEM 1 FLA 120 1 1.0 6A 20 - 19 - 15 REFERENCE NOTES: 1. NON-FUSED DISCONNECT SWITCH A. FURNISHED, INSTALLED AND FINAL CONNECTION BY THE 2. FUSED DISCONNECT SWITCH ELECTRICAL CONTRACTOR. 3. BREAKER IN ENCLOSURE B. FURNISHED AND INSTALLED UNDER ANOTHER DIVISION, 4. FUSED DISCONNECT SWITCH WITH SHUNT TRIP FINAL CONNECTION BY THE ELECTRICAL CONTRACTOR. 5. MANUAL STARTER WITH THERMAL OVERLOAD C. FURNISHED UNDER ANOTHER DIVISION, INSTALLED AND 6. MANUAL STARTER FINAL CONNECTION BY THE ELECTRICAL CONTRACTOR. 7. MAGNETIC STARTER/NON-FUSED DISCONNECT COMBINATION D. FURNISHED, INSTALLED AND FINAL CONNECTION UNDER 8. MAGNETIC STARTER/FUSED DISCONNECT COMBINATION ANOTHER DIVISION. 9. MAGNETIC STARTER/MOTOR CIRCUIT PROTECTOR COMBINATION 10. VARIABLE SPEED DRIVE 11. REDUCED VOLTAGE STARTER 12. DIRECT CONNECTION 13. RECEPTACLE/SPECIAL PURPOSE OUTLET ETC. 14. TWO-SPEED STARTER, COORDINATE WITH MOTOR TYPE 15. MAXIMUM CIRCUIT AMPS (MCA) 16. FULL LOAD CURRENT 17. PROVIDE WITH NEMA 1 ENCLOSURE 18. PROVIDE WITH NEMA 3R ENCLOSURE 19 PROVIDE WITH NEMA 4X ENCLOSURE GENERAL NOTES: A.VERIFY ALL EQUIPMENT LOCATIONS AND CONNECTION REQUIREMENTS (i.e. VOLTAGE, PHASE, FLA, ETC.) WITH MECHANICAL DRAWINGS/SUBMITTALS PRIOR TO STARTING ROUGH IN. B.ALL FUSES SHALL BE DUAL ELEMENT, TIME DELAY. FINAL BREAKER/FUSE & DISCONNECT SIZE SHALL BE DETERMINED BY MANUFACTURER'S RECOMMENDATION FOR ACTUAL EQUIPMENT INSTALLED. C.ALL INSULATION ON CONDUCTORS TO BE THHN UNLESS NOTED OTHERWISE. INSULATION ON ALL UNDERGROUND EXTERIOR CONDUCTORS SHALL BE THHW. T A 39077PE FEOPRSSI NO M O N N EN GEL I REAAN NLIEC DES TERRYGORSETH 233 SOUTH PLEASANT GROVE BLVD. SUITE #105 PLEASANT GROVE, UTAH 84062 PHONE: (801) 769-3000 core@corearch.com THE INFORMATION HEREIN IS THE PROPERTY OF CORE ARCHITECTURE AND MAY NOT BE REPRODUCED WITHOUT WRITTEN CONSENT. © 2023 CORE ARCHITECTURE, LLC PROFESSIONAL STAMP SHEET NUMBER SHEET TITLE A 1 REVISIONS DATE: PROJECT #: PM / PA: PIC: PROJECT INFORMATION DESCRIPTION DATE THIS DRAWING SET IS INTENDED TO BE PRINTED IN COLOR CONSULTANT INFORMATION DRAWING SET STATUS B C D 2 3 4 5 6 PROJECT TITLE AND ADDRESS8/2/2023 10/2/2023 3:13:10 PMAutodesk Docs://23-029 Bozeman Multifamily/ELEC_BozemanMultifamily_23076_v23.rvtELECTRICAL SCHEDULES E502 2 AUG. 2023 PVE No. 23076 TLG TLG PERMIT REVIEW AND BID SETTHE BOÖTES - SITEAND CLUBHOUSEOPPORTUNITY WAY AND SOUTH11TH AVEBOZEMAN, MONTANA 597182 1 Addendum #1 10-2-2023 2 Review Comments 10-2-2023